Job Information
Type:
"JSQPSU3PBE'BMM3JWFS."t t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt
Lighting Systems
PTS7-2
1BHFPG
1FSJNFUFS5SPVHI3FDFTTFE%JSFDU-PVWFS-JHIU51FS'PPU4FDUJPO
$
Performance
TWO
Cat No.
PTS7T242 PTS7T254
PTS7296
PTS7248
PTS7236
PTS7224
Size
27" to 42" 39" to 54"
96"
48"
36"
24"
Lamps
2-2 Foot
2-3 Foot
4-4 Foot
2-4 Foot
2-3 Foot
2-2 Foot
Type
Tele
Tele
Module
Module
Module
Module
2'3"-3'6"
1
3'3"-4'6"
1
4'3"-5'6"
1
1
5'3"-6'6"
1
1
6'3"-7'6"
1
1
7'3"-8'6"
1
1
8'3"-9'6"
1
1
1
9'3"-10'6"
1
2
10'3"-11'6"
1
1
1
11'3"-12'6"
1
1
12'3"-13'6"
1
1
1
1
13'3"-14'6"
1
1
1
14'3"-15'6"
1
1
1
15'3"-16'6"
1
1
1
16'3"-17'6"
1
1
1
1
17'3"-18'6"
1
1
2
18'3"-19'6"
1
1
1
1
19'3"-20'6"
1
2
20'3"-21'6"
1
1
1
1
1
21'3"-22'6"
1
2
1
22'3"-23'6"
1
2
1
23'3"-24'6"
1
2
1
24'3"-25'6"
1
2
1
1
25'3"-26'6"
1
2
2
26'3"-27'6"
1
2
1
1
27'3"-28'6"
1
3
28'3"-29'6"
1
2
1
1
1
29'3"-30'6"
1
3
1
30'3"-31'6"
1
3
1
31'3"-32'6"
1
3
1
32'3"-33'6"
1
3
1
1
33'3"-34'6"
1
3
2
34'3"-35'6"
1
3
1
1
35'3"-36'6"
1
4
36'3"-37'6"
1
3
1
1
1
37'3"-38'6"
1
4
1
38'3"-39'6"
1
4
1
39'3"-40'6"
1
4
1
40'3"-41'6"
1
4
1
1
41'3"-42'6"
1
4
2
42'3"-43'6"
1
4
1
1
43'3"-44'6"
1
5
44'3"-45'6"
1
4
1
1
1
45'3"-46'6"
1
5
1
46'3"-47'6"
1
5
1
47'3"-48'6"
1
5
1
48'3"-49'6"
1
5
1
1
49'3"-50'6"
1
5
2
50'3"-51'6"
1
5
1
1
Quick Calculators
85˚
75˚
65˚
45˚
55˚
0˚ 5˚ 15˚ 25˚ 35˚
1000
1250
750
1500
1750
500
CANDLEPOWER CURVE
REPORT NO: LRL 499-5E
LAMPS: 2-32WT8
LUMENS: 2900
EFFICIENCY: 45.6%
Ordering Information
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
54
54
54
53
53
53
51
51
51
1
49
47
46
48
46
45
46
45
44
2
44
41
39
43
41
39
41
39
38
3
39
36
34
39
36
34
37
35
33
4
36
32
29
35
32
29
34
31
29
5
32
28
26
31
28
25
30
27
25
6
29
25
23
29
25
22
28
25
22
7
26
23
20
26
22
20
25
22
20
8
24
20
18
23
20
17
23
20
17
9
21
18
15
21
18
15
21
17
15
10
20
16
14
19
16
14
19
16
14
CANDLEPOWER SUMMARY
ZONE
Deg
0
45
90
135
180
180
0
0
0
0
0
175
0
0
0
0
0
165
0
0
0
0
0
155
0
0
0
0
0
145
0
0
0
0
0
135
0
0
0
0
0
125
0
0
0
0
0
115
0
0
0
0
0
105
0
0
0
0
0
95
0
0
0
0
0
90
0
0
0
0
0
85
94
37
5
2
2
75
483
132
10
7
7
65
894
298
28
17
21
55
1178
748
168
68
32
45
1387
1118
544
133
65
35
1586
1365
882
206
114
25
1679
1553
1117
502
223
15
1721
1617
1279
851
658
5
1547
1495
1369
1231
1171
0
1382
1382
1382
1382
1382
ONE SIDE MOUNTING
NO OPPOSITE WALL
1.5 112
2.5
57
3.5
38
4.5
30 138 100
65
46
36
30
5.5
26
6.5
24
7.5
23
88
84
69
55
45
38
8.5
22
9.5
21
68
70
62
53
45
39
0
2
4
6
8
10
12
DISTANCE FROM WALL, FEET
TWO SIDE MOUNTING
12 FT BETWEEN WALLS
1.5 142
142
2.5
92
92
3.5
77
77
4.5
72 170 144 129 144 170
72
5.5
69
69
6.5
67
67
7.5
65 130 135 134 135 130
65
8.5
63
63
9.5
60 115 124 125 124 115
60
0
2
4
6
8
10
12
DISTANCE FROM WALL, FEET
ONE SIDE MOUNTING
6 FT BETWEEN WALLS
1.5 135
78
2.5
80
88
3.5
61
88
4.5
53 155 124
85
5.5
48
78
6.5
45
71
7.5
42 106 104
64
8.5
39
58
9.5
36
87
89
53
0
2
4
6
DISTANCE FROM WALL, FEET
HORIZONTAL FC
VERTICAL FC
DIST
ANCE FROM CEILING, FT
0 deg
90 deg
180
deg
0 deg
90 deg
180
deg
NOTE:
Add to end of catalog nu
m
ber for desired ballast.
E81
= T8 Electronic 120v
E82
= T8 Electronic 227v
M71
= T8 Electronic Di
mm
ing Ballast 120v
M72
= T8 Electronic Di
mm
ing Ballast 277v
Ordering Instructions
Individual Fixtures:
1. Order nu
m
ber of FIXTURES.
2. Order one END PLATE SET per fixture.
Continuous Rows:
1. Deter
m
ine run length.
2. Use chart above to find catalog nu
m
bers. Each run ends with a telescoping unit.
3. Order END PLATE SET for each open run.
Square/Rectangle Patterns:
1. Consult plans and
m
ark locations for corners.
2. Calculate net footage of each run.
3. Deduct corner di
m
ension fro
m
each corner.
4. Deter
m
ine catalog nu
m
bers the sa
m
e way as a straight run.
ZONAL LUMEN SUMMARY
ZONE
LUMENS
% BARELAMP
% LUMINAIRE
0-90
2644
45.6
100.0
90-180
0
0.0
0.0
0-180
2644
45.6
100.0
ROOM CA
VITY RA
TIO
LIGHT