ProSpec

®

 120V/277V Track Lighting

  37224

Page 2 of 2 

PowerWash

 T5 2 Foot Track Mounted 24 Watt High Output Fluorescent

EXAMPLE:  With track located 4’ from wall and multiple units spaced 6’ on center and aimed 
45˚ from horizontal, the illumination on wall 4’ from ceiling will be 33 f.c. beneath units and 27 
f.c. between units.

   

0’ 

1’ 

2’ 

3’ 

4’  5’

   

0’ 

1’ 

2’ 

3’ 

4’  5’

Lighting Data 2 - 24W T5 High Output

   

 

  1’ 

100 

78 

40 

18 

5

  2’ 

78 

62 

35 

16 

3

  3’ 

48 

41 

26 

15 

3

  4’ 

31 

27 

19 

12 

4

  5’ 

18 

16 

12 

3

  6’ 

11 

11 

3

  7’ 

2

  8’ 

  9’ 

2

 

 

 

120  88  120

 

92  74  92

 

63  56  63

 

48  45  48

 

29  20  29

 

23  22  23

 

15  15  15

 

11  11  11

 

9

 

 

 

107  38  107

 

80  33  80

 

51  29  51

 

37  20  37

 

21  17  21

 

17  15  17

 

11  10  11

 

8

 

6

Footcandles on Wall

  Track 3 Feet From Wall 

Single Unit 

Multiple  Units

4’

6’

3’

Distance From Ceiling

45˚

   

 

  1’ 

54 

44 

27 

13 

1

  2’ 

53 

45 

30 

16 

4

  3’ 

39 

34 

24 

15 

4

  4’ 

29 

25 

19 

13 

5

  5’ 

20 

18 

15 

11 

5

  6’ 

13 

12 

10 

4

  7’ 

3

  8’ 

3

  9’ 

2

 

 

 

62  53  62

 

69  62  69

 

56  52  56

 

46  44  46

 

38  37  38

 

27  26  27

 

20  20  20

 

17  17  17

 

13  13  13

 

 

 

56  37  56

 

60  45  60

 

47  39  47

 

38  34  38

 

32  29  32

 

22  21  22

 

17  16  17

 

14  14  14

 

11  10  11

 

 

 

54  25  54

 

56  32  56

 

43  29  43

 

33  27  33

 

28  24  28

 

19  17  19

 

14  13  14

 

12  12  12

 

9

 

  Track 4 Feet From Wall 

Single Unit 

Multiple  Units

4’

5’

6’

4’

Distance From Ceiling 

45˚

Footcandles are average and rounded off and data for multiple units are based on a minimum of five units.

Footcandles on wall:

 One Lamp, with louver,

aimed 45˚ down. 

 Two Lamps, without louver,

aimed 45˚ up. 

 Two Lamps, with louver,

aimed 45˚ down. 

Beam Center

Beam Center

La mp Information:
2 X 24W T5 High Output
Mini Bi-Pin Fluorescent (9276)
1 x 24W T5 High Output
Mini Bi Pin Fluorescent (9277)

 

 

 

111  58  111

 

84  50  84

 

54  41  54

 

41  35  41

 

24  21  24

 

19  18  19

 

13  12  13

 

9

 

7

5’

   

0’ 

1’ 

2’ 

3’ 

4’  5’

   

 

  1’ 

37 

32 

23 

15 

5

  2’ 

37 

33 

24 

16 

10 

6

  3’ 

33 

30 

23 

16 

10 

6

  4’ 

24 

22 

17 

13 

5

  5’ 

18 

17 

14 

10 

5

  6’ 

14 

13 

11 

5

  7’ 

10 

10 

4

  8’ 

3

  9’ 

3

 

 

 

57  54  57

 

60  57  60

 

58  56  58

 

44  43  44

 

36  35  36

 

30  30  30

 

25  25  25

 

19  18  19

 

15  15  16

 

 

 

49  42  49

 

51  45  51

 

49  45  49

 

36  34  36

 

30  29  30

 

25  24  25

 

21  20  21

 

15  15  15

 

13  13  13

 

 

 

44  32  44

 

45  35  45

 

44  36  44

 

32  28  32

 

25  23  25

 

22  20  22

 

18  17  18

 

13  12  13

 

11  11  11

 

  Track 5 Feet From Wall 

Single Unit 

Multiple  Units

4’

5’

6’

5’

Distance From Ceiling 

45˚

Beam Center

one lamp aimed 
45degrees down

0˚                  30˚

90˚

60˚

180˚             150˚

120˚

90˚

0˚                  30˚

90˚

60˚

Reviews: