Lightolier Pendalyte 404722XU3 Specification Download Page 2

Lightolier is a Philips group brand

Job Information 

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • I0109

Specification Decorative Pendalyte

  404722XU3

Page 2 of 2 

12" 2 Lamp Pendant  

Application Data

Multiple Units

 

(2x26W Triple Tube ) with cross blade louver

 

Spacing 

Height 

Initial  

Watts 

 

on  

to Lighted 

Foot- 

Per 

 

Center 

 Plane 

candles 

Sq. Ft.

 

6’

 

6’ 

75

 

1.50

 

 

12’ 

68

 

 

8’

 

6’ 

42

 

0.86

 

 

12’ 

38

 

10’ 

6’ 

27

 

0.55

 

 

12’ 

24

 

Based on 60" x 60" room with 80% ceiling cavity, 50% wall and 20% floor reflectances. 
Height is from bottom of fixture to lighted plane.

  0 

813

  5 

898 

86

  10 

976

  15 

936 

266

  20 

907

  25 

905 

416

  30 

874

  35 

831 

522

  40 

789

  45 

722 

552

  50 

620

  55 

479 

423

  60 

308

  65 

156 

177

  70 

95

  75 

66 

70

  80 

39

  85 

15 

20

  90 

1

CERTIFIED TEST REPORT NO. 0807FR COMPUTED BY LSI PROGRAM **TEST-LITE**

LIGHTOLIER DUAL COMPACT FLUORESCENT PENDANT FIXTURE CAT. #4047233/404L12    

12 1/2" DIA. CLEAR ANODIZED REFLECTOR WITH WHITE CROSS BLADE          

2-26W PLT TRIPLE TUBE PHILIPS LAMPS. LUMEN RATING = 1800 LMS.          

ESI BALLAST CAT.#ESI 2/1-CFQ-26UNV, 120 VAC                   

ROOM

 CA

VITY

 RA

TIO

            COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD

                   %EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

 

80 

70 

50 

30 

10

 

50  30  10     50  30  10   50  30  10   50  30  10   50  30  10    0 

  1 

.75 .73 .71  .74 .72 .70  .71 .69 .68  .68 .67 .65  .66 .65 .64  .62

 

  2 

.68 .64 .61  .67 .63 .60  .64 .61 .59  .62 .60 .57  .60 .58 .56  .55

 

  3 

.61 .56 .52  .60 .55 .52  .58 .54 .51  .56 .53 .50  .54 .52 .49  .48

 

  4 

.55 .50 .46  .54 .49 .45  .52 .48 .45  .51 .47 .44  .49 .46 .44  .42

 

  5 

.50 .44 .40  .49 .43 .40  .47 .43 .39  .46 .42 .39  .45 .41 .38  .37

 

  6 

.44 .39 .35  .44 .38 .35  .43 .38 .34  .41 .37 .34  .40 .37 .34  .32

 

  7 

.40 .34 .30  .39 .34 .30  .38 .33 .30  .37 .33 .29  .36 .32 .29  .28

 

  8 

.36 .30 .26  .35 .30 .26  .35 .30 .26  .34 .29 .26  .33 .29 .26  .25

 

  9 

.33 .27 .23  .32 .27 .23  .31 .26 .23  .31 .26 .23  .30 .26 .23  .21

 

 10 

.29 .24 .38   .29 .24 .20  .28 .24 .20  .28 .23 .20  .27 .23 .20  .19

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

Spacing Ratio = 1.5 

2x26W Triple Tube CFL

Coefficients Of Utilization 

2-26W Triple Tube CFL

Illuminance (FC) Multipliers

 For Compact Fluorescent:

 

32 Watt = 1.3 

42 Watt = 1.8

Application Data

Spacing Ratio = 3.3 

2x32W Triple Tube CFL

Coefficients Of Utilization 

2x32W Triple Tube CFL

Multiple Units

 (2x32W Triple Tube, CFL)

 

Spacing 

Height 

Initial  

Watts 

 

on  

to Lighted 

Foot- 

Per 

 

Center 

 Plane 

candles 

Sq. Ft.

 

6’

 

6’ 

62

 

1.00

 

 

12’ 

53

 

 

8’

 

6’ 

35

 

0.56

 

 

12’ 

30

 

 

10’ 

6’ 

22

 

0.36

 

 

12’ 

19

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

80 

70 

50 

30 

10 

0

 

  50  30  10 

50  30  10 

50  30  10 

50  30  10 

50  30  10 

0

 
 1    .73  .70  .67  .70  .67  .63  .63  .60  .58 

.56  55  .53 

.51  .49  .48  .45

 2    .64  .58  .54  .60  .56  .51  .55  .51  .47 

.49  .46  .43 

.44  .42  .40  .37

 3    .55  .49  .44   .53  .47  .42  .48  .43  .39 

.43  .39  .36 

.39  .36  .33  .30

 4    .49  .42  .37  .47  .41  .36  .42  .37  .33 

.38  .34  .31 

.34  .31  .28  .26

 5    .43  .36  .31  .41  .35  .30  .37  .32  .28 

.34  .29  .26 

.30  .27  .24  .22

 6    .38  .31  .26  .36  .30  .25  .33  .27  .23 

.30  .25  .22 

.27  .23  20  .18

 7  .  33  .27  .22  .32  .26  .21  .29  .23  .20 

.26  .21  .18 

.23  .20  .17  .15

 8    .30  .23  .19  .28  .22  .18  .26  .20  .17 

.23  .19  .15 

.21  .17  .14  .12

 9    27  .20  .16  .25  .19  .15  .23  .18  .14 

.21  .16  .13 

.19  .15  .12  .10

10    .24  .18  .32  .23  .17  .13  .21  .16  .12 

.19  .14  .11 

.17  .13  .10  .09

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

20% FLOOR CAVITY REFLECTANCE

ROOM

 CA

VITY

 RA

TIO

% WALL REFLECTION

Based on 60" x 60" room with 80% ceiling cavity, 50% wall and 20% floor reflectances. 
Height is from bottom of fixture to lighted plane.

LIGHTOLIER DUAL COMPACT FLUORESCENT PENDANT FIXTURE CAT. #4047233/40422

12 1/2" DIA. REFRACTOR WITH PLASTIC LENS

2-32W PLT TRIPLE TUBE PHILIPS LAMPS. LUMEN RATING = 2400 LMS

MOTOROLA BALLAST CAT.M2CF26/32/42

297

324 

32

10 

387

15 

469 

133

20 

541

25 

605 

280

30 

667

35 

725 

451

40 

752

45 

726 

553

50 

650

55 

547 

490

60 

440

65 

343 

342

70 

250

75 

187 

217

80 

196

85 

201 

218

90 

198

95 

210 

226

100 

209

105 

208 

221

110 

210

115 

204 

201

120 

189

125 

170 

153

130 

148

135 

122 

95

140 

95

145 

67 

43

150 

42

155 

26 

14

160 

19

165 

17 

5

170 

15

175 

12 

2

180 

11

 

0-30 

443 

9.25 

12.10

 

0-40 

894 

18.63 

24.39

 

0-60 

1936 

40.35 

52.80

 

0-90 

2712 

56.51 

73.96

  40-90 

1818 

37.88 

49.58

  60-90 

776 

16.17 

21.16

  90-180 

954 

19.89 

26.04

  0-180 

3667 

76.41 

100.00

**  EFFICIENCY = 76.4%  **

Illuminance (FC) Multipliers

 For Compact Fluorescent:

 

26 Watt = 0.7 

42 Watt = 1.3

0-30 

767 

21.31 

30.30

0-40 

1289 

35.82 

50.92

0-60 

2265 

62.91 

89.44

0-90 

2532 

70.34 

100.00

40-90 

1242 

34.52 

49.08

60-90 

267 

7.43 

10.56

90-180 

.00 

.00

0-180 

2532 

70.34 

100.00

**  EFFICIENCY = 70.3%  **