PHOTOMETRY

MODEL NO. MPA2G36LP32U

coefficients of utilization — zonal cavity method

RF

20

20

20

RC

80

50

30

RW

70

50

30

50

30

10

50

30

10

1

61

59

57

56

54

53

54

53

52

2

57

53

50

50

48

46

49

47

45

3

53

48

44

45

43

40

44

42

40

4

49

43

39

41

38

35

40

37

35

5

45

39

35

37

34

31

36

33

31

6

42

35

31

34

30

28

33

30

27

7

39

32

28

31

27

25

30

27

25

8

36

30

25

29

25

22

28

25

22

9

34

27

23

26

23

20

26

23

20

10

32

25

21

25

21

19

24

21

18

visual comfort probability 

(VCP) average 100 fc; reflectances 80/50/20

room size

ceiling height

ceiling height

W

L

8.5

10.0

13.0

16.0

8.5

10.0

13.0

16.0

20

20

77

70

62

67

77

69

62

65

20

30

79

73

67

62

79

72

66

62

20

40

82

76

71

65

81

75

70

65

20

60

83

78

73

69

83

77

72

68

30

20

81

75

65

66

81

74

65

65

30

30

83

77

69

61

83

76

68

62

30

40

85

79

72

65

85

78

71

65

30

60

86

81

75

68

86

80

74

68

30

80

87

82

77

71

87

82

76

70

40

20

83

77

69

68

82

77

69

66

40

30

85

80

73

63

84

79

72

63

40

40

86

81

75

67

86

81

75

66

40

60

87

83

77

69

87

82

77

69

40

80

88

84

79

72

88

84

79

71

40

100

88

85

81

74

88

84

80

73

60

30

85

81

75

67

85

80

74

67

60

40

87

82

77

70

87

82

77

69

60

60

88

84

79

72

88

83

79

71

60

80

88

85

81

74

88

85

80

74

60

100

89

86

82

76

89

85

82

75

100

40

87

82

79

71

87

82

78

71

100

60

88

84

81

74

88

84

80

73

100

80

88

85

82

76

89

85

82

76

100

100

89

86

83

78

89

85

83

77

room cavity ratio

luminaries lengthwise

luminaries crosswise

ORDERING INFORMATION

Explanation of Catalog Number.   Example: MPA2G36LP32U120O3RF

OPTIONS/ACCESSORIES

PLASTER FRAME

: Catalog Number: 

PF22

.

CONTINUOUS ROW INSTALLATION

: For F type

fixtures, half-width flanges are required between fixtures. Order Catalog Number: 

S2FCTRIM

(each

joint).

SPLAY TRIM

: For T ceiling type only.

SUFFIX: 

CTZ22 S2 SPLAY TRIM

.

MP

PARABAFFLE

1-1/2" PARABOLIC:

Pre-anodized

aluminum louver

BODY STYLE:

A=

Air Supply

S=

Static

2

FIXTURE

WIDTH

CEILING TYPE:

G

= Grid

(lay-in T bar)

F

=Flanged

(overlap)

Z spline and
plaster frame

T

=Slot grid or       

two-directional
concealed T
(see options)

36

NUMBER OF

CELLS

LOUVER

FINISH*:

L

= Low

Iridescence
Semi-specular
(standard)

P

= Low

Iridescence
Specular

W

=White Baked

Enamel

P

=Dual “V”

Reflector
(3 Lamp)

S

=Single “V”

Reflector
(2 Lamp)

LAMP

QUANTITY

:

2

=2 Lamp

3

=3 Lamp

LAMP TYPE/

FIXTURE LENGTH:

2U

=T8, 1-5/8"U Lamp

17

=T8, 2' Lamp

(Nominal 48")

VOLTAGE:

120 or 277

OPTIONS:

Add appropriate
suffix to catalog

no, ie: (RF)

BALLAST TYPE:

<

20THD

<

10THD

1 & 2 Lamp Elec. T8

SO*

H

I

*

1-3 Lamp Elec. T8

O3*

H3*

LOL T8 Dimming

PS

*

Instant Start Standard

Other dimming options. Consult factory.

Luminaire Efficacy Rating
LER-50.8   Watts-77.6   BF-0.88

MPA2C36LP120O3

PARABAFFLE plus

MPA2G36LP32U or 17

Page 2 of 2

2'x2' RECESSED FLUORESCENT, 11/2" DEEP, 36 CELL PARABOLIC LOUVER,

STATIC OR AIR SUPPLY/RETURN, 2 OR 3 LAMP, T8, 1-5/8"U LAMP OR 2' LAMP

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902

Section 2/Folio G20-14

Job Information

Type:

RADIO INTERFERENCE FILTER

: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUF-

FIX: 

RF

.

ELECTRICAL/WIRING OPTIONS

: Consult factory.

AIR CLOSURE STRIP

: SUFFIX: 

ACS2

(factory installed).

DRYWALL KIT

: Order Catalog Number: 

FK92X2

.

(Request Folio OA30-10)

CHICAGO PLENUM

: SUFFIX: 

CP

.

SPECIFICATIONS:

PERFORMANCE

: In an installation of 3 lamp 31W luminaires in a room cavity ratio of

1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .59.
To prevent glare the VCP shall be not less than 71 either lengthwise or crosswise (at 100fc
level) and the average brightness at 65° shall not exceed 1338 candelas per square meter.
To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than
62.7%.

AIR HANDLING

(MPA only) side air passages for air supply or air return. Supply air is

discharged vertically. Optional side closure strips. Air return is also provided through the
lamp compartment through fixture body ends.

MATERIALS

Chassis parts

are die-formed code gauge cold rolled steel. Housing is

ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling.

Louver

is pre-anodized

aluminum (Coilzak

®

or equal).

FINISH

Chassis exterior

–black baked polyester enamel. 

Cavity

– white baked poly-

ester enamel minimum 86% reflectance. Phosphate undercoating. 

Louver

–low irides-

cence semi-specular anodized vertical grain aluminum reflector sheet is standard.

ELECTRICAL

: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O.

is within 3" of ballast, use wire suitable for at least 90°.

LABELS

: I.B.E.W. UL and ULc Listed.