background image

Specular anodized aluminum mirror,
adjusts to left or right side of bed

120V medium base narrow spot,
50W reflector lamp

   

MD*4 2' x 2' Recessed or Surface 

MD2G2SB

Page 3 of 4

Multi-Function Patient Lighting

Nurses Night Light 

(Optional)

Lights night stand between beds.
Field adjustable for either right or left side of patient's bed.
No glare to any patient.
Wired for independent switching.

Options 

Sequential Switch. 

Suffix: 

SW

MD*4’s optional low voltage (1-3 volts) sequential switch mounted in the fixture is listed in com-
pliance with UL 544 for medical and dental equipment. Two red wires coming from the fixture can
be wired to a wall receptacle (by others) for use with that manufacturers pillow speaker. The pil-
low speaker is used to control the television, call the nurse and control the lighting. To control
the lighting it should be specified to have a normally open contact switch.
Pressing this switch on the pillow speaker the first time, turns the ambient light on; pressed a
second time, turns the reading light on and the ambient light off; pressed a third time, turns both
the ambient and reading lights on; pressed a fourth time turns both lights off. Pressing the button
again repeats the cycle.
Should the patient's bed be rolled away from the wall, the pillow speaker will simply pull free
from the wall receptacle avoiding any damage.

Nurse's night light. 

Suffix: 

NL

CAN BE SET TO

LEFT OR RIGHT

SIDE OF BED

Pillow speaker (by others)

Night Light

: 12V, 3 watt, cool white LED (50,000

hours life) (supplied with fixture). Suffix: 

LD

Summary of Contents for MD2G2SB

Page 1: ... Function Patient Lighting Lightolier a Genlyte company www lightolier com Technical Information 978 657 7600 Fax 978 658 0595 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2007 a Genlyte company Section 8 Folio R40 12 Rev B S Surface G exposed T grid ceiling MOUNTING METHODS DIMENSIONS 1 Reading light with ...

Page 2: ...ors 7 footcandles maximum at head of bed 15 footcandles maximum at foot of bed Controls light directly onto patient s bed No reading light spill over to adjacent bed 2 foot candles maximum at head of adjacent patient s bed MD 4 2 x 2 Recessed or Surface MD2G2SB Page 2 of 4 Multi Function Patient Lighting Illumination at the reading task range 50 60 footcandles READING LIGHT ON ADJACENT MD 4 OFF FO...

Page 3: ...e with that manufacturers pillow speaker The pil low speaker is used to control the television call the nurse and control the lighting To control the lighting it should be specified to have a normally open contact switch Pressing this switch on the pillow speaker the first time turns the ambient light on pressed a second time turns the reading light on and the ambient light off pressed a third tim...

Page 4: ...0 Labels I B E W UL and ULc Listed This product may have a mercury containing lamp Manage in accord with Disposal Laws See www lamprecycle org Options Accessories Access Plates Top wiring access plate is shipped with fixture as standard When access plates are required in advance for wiring convenience specify separately Catalog Number ACP Drywall Kit or Plaster Ceiling Order Catalog Number FK92X2 ...

Reviews: