Job Information 

Type:

Lytecaster

®

 Performance Recessed CFL Downlighting 

2001L

Page 2 of 2 

3 ¾" Aperture Vertical Wet Location, Compact Fluorescent, Performance Series, 

Reflector Trim

18W TRIPLE TUBE LAMP

, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH FRESNEL LENS

18W TRIPLE TUBE LAMP

, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH OPAL LENS

18W TRIPLE TUBE LAMP

, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH CLEAR LENS

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70% 

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room 

Cavity 

Ratio

0 36  36  36  36  35  35  34  34  32  32  30
1 34  33  32  31  32  31  31  30  30  29  27
2 32  30  28  27  29  26  28  27  26  27  24
3 29  27  25  23  26  23  26  23  25  22  21
4 27  24  22  20  24  20  23  20  22  20  19
5 25  22  20  18  22  18  21  18  20  17  17
6 24  20  18  16  20 16  19  16  19  16  15
7 22  18  16  14  18  14  18  14  17  14  13
8 20  17  14  13  17  13  16  13  16  13  12
9 19  15  13  12  15  12  15  11  15  11  11

10 18  14 12  11  14  10  14  10  14  10  10

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 22.0

1

50

100

150

200

60˚

30˚

SC = 1.6

CERTIFIED TEST REPORT NO. 3349FR
COMPUTED BY LSI PROGRAM 
**TEST-LITE**

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens %Lamp

%Fixt

0-30

139.25 

11.6

 38.1

0-40

232.59 

19.4 

63.6

0-60

353.98 

29.5 

96.8

0-90

365.87 

30.5 

100

90-120

0

90-130

0

90-150

0

90-180

0

 0

 0

0-180 365.87 

30.5 

100

**  Efficiency = 30.5%** 

ZONAL LUMEN SUMMARY

Zone

Lumens

0-10

13.37

10-20

46.72

20-30

79.16

30-40

93.34

40-50

79.65

50-60

41.74

60-70

10.17

70-80

1.58

80-90

.14

90-100

0

100-110

0

110-120

0

120-130

0

130-140

0

140-150

0

150-160

0

160-170

0

170-180

0

CANDLEPOWER SUMMARY

Angle

0˚ CP

129

135

10 

150

15

165

20 

173

25 

172

30 

165

35 

150

40 

131

45 

104

50 

74

55 

46

60 

24

65 

8

70 

3

75

1

80 

1

85 

0

90 

0

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70% 

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room 

Cavity 

Ratio

0 35  35  35  35  34  34  33  33  31  31  30
1 33 32  31  30  31  30  29  28  27  27  26
2 31  29  27  26  28  25  27  25  26  24  23
3 28  26  24  22  25  22  24  22  24  21  20
4 26  23  21  19  23  19  22  19  21  19  18
5 24  21  19  17  21  17  20  17  20  17  16
6 23  19  17  15  19  15  18  15  18  15  14
7 21  17  15  13  17  13  17  13  16  13  13
8 20  16  14  12  16  12  13  15  13  12  11
9 18  15  12  11  15  11  14  11  14  11  10

10 17  14  11  10  13  10  13  10  13  10  9

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 22.0

1

50

100

150

200

60˚

30˚

SC = 1.4

CERTIFIED TEST REPORT NO. 3348FR
COMPUTED BY LSI PROGRAM 
**TEST-LITE**

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens %Lamp

%Fixt

0-30

131.6 

11 

37

0-40

217.11 

18.1

 61.1

0-60

333.76 

27.8 

93.9

0-90

355.26 

29.6

100

90-120

0

90-130

0

90-150

0

90-180

0

 0

 0

0-180

355.26 

29.6

100

**  Efficiency = 29.6%** 

ZONAL LUMEN SUMMARY

Zone

Lumens

0-10

14.54

10-20

44.62

20-30

72.45

30-40

85.51

40-50

73.84

50-60

42.8

60-70

16.63

70-80

4.73

80-90

.14

90-100

0

100-110

0

110-120

0

120-130

0

130-140

0

140-150

0

150-160

0

160-170

0

170-180

0

CANDLEPOWER SUMMARY

Angle

0˚ CP

151

152

10 

154

15

157

20 

159

25 

158

30 

151

35 

138

40 

119

45 

97

50 

71

55 

47

60 

28

65 

16

70 

9

75

4

80 

1

85 

0

90 

0

1

50

100

150

200

60˚

30˚

SC = 1.1

CERTIFIED TEST REPORT NO. 3350FR
COMPUTED BY LSI PROGRAM 
**TEST-LITE**

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70% 

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room 

Cavity 

Ratio

0 31 31 31  31  30  30  29  29  28  28  26
1 29 28  27  26  27  26  26  25  25  24  23
2 27 25  23  22  24  22  23  21  23  21 20
3 24 22  20  19  22  19  21  18  20  18 17
4 23 20  18  16  20  16  19  16  18  16  15
5 21 18  16  14  18  14  17  14  17  14  13
6 19

6  14  13  16  13  16  12  15  12

12

7 18 15  13  11  15  11  14  11  14  11  11
8 17  14  12  10  13  10  13  10  13  10  9
9 16  13  11  9  12  9  12  9  12  9 

9

10 15  12  10  8  12  8 

11  8 

11  8

 8

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 22.0

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens %Lamp

%Fixt

0-30

111.65 

9.3 

35.8

0-40

175.81 

14.7 

56.4

0-60

279.09 

23.3 

89.6

0-90

311.48 

26 

100

90-120

0

90-130

0

90-150

0

90-180

0

 0

 0

0-180

311.48 

26

100

**  Efficiency = 26%** 

ZONAL LUMEN SUMMARY

Zone

Lumens

0-10

14.23

10-20

39.88

20-30

57.54

30-40

64.16

40-50

58.87

50-60

44.41

60-70

25.17

70-80

7.09

80-90

.14

90-100

0

100-110

0

110-120

0

120-130

0

130-140

0

140-150

0

150-160

0

160-170

0

170-180

0

CANDLEPOWER SUMMARY

Angle

0˚ CP

151

150

10 

147

15

142

20 

134

25 

125

30 

115

35 

103

40 

90

45 

76

50 

63

55 

50

60 

37

65 

25

70 

   15

75

6

80 

1

85 

0

90 

0

Reviews: