 Silhouette

®

 SE

1BHFPG

-PVWFSFE*OEJSFDU%JSFDU-JHIU5QFS'PPU /PNJOBM4FDUJPO

Mounting & Joiner Block Accessories

“X” Block with Suspension

SX36WH (white)
SX36AL (aluminum)

Inline block available (

SI36WH or SI36AL).

“L”Block with Suspension

SL36WH (white)
SL36AL (aluminum)

“T” Block with Suspension

ST36WH (white)
ST36AL (aluminum)

Power Feed End Set

SE36WH (white)
SE36AL (aluminum)

Cable Asse

m

bly

SC36

Sa

m

ple Run

Fixture Lengths & Mounting Locations

4-Foot Joiner

4-Foot Joiner

8-Foot Joiner

5/8” (1.59c

m

)

1-1/4” (3.18c

m

)

Power Feed

End Set

Cable

Asse

m

bly

8-Foot Joiner

8-Foot Joiner

96” (243.84c

m

)

48” (121.92c

m

)

48” (121.92c

m

)

96” (243.84c

m

)

96” (243.84c

m

)

20’ 1/8” (609.92c

m

)

8” (20.32c

m

)

4”
(10.16c

m

)

4” (10.16c

m

)

3.4”

(8.64c

m

)

8”

(20.32c

m

)

4”
(10.16c

m

)

4.6” (11.68c

m

)

4” (10.16c

m

)

CANDLEPOWER

ZONE       0       22         45          67        90
DEG.

CANDELAS

180

598

598

598

598

598

175

600

592

588

579

578

165

590

574

590

642

646

155

557

557

654

722

740

145

496

555

673

730

754

135

409

515

623

730

760

125

330

452

612

796

808

115

220

348

648

847

898

105

122

312

578

670

698

95

28

171

217

225

225

90

9

38

47

74

72

85

17

29

50

66

68

75

51

52

62

72

83

65

86

83

89

101

94

55

150

149

157

148

177

45

261

254

306

269

243

35

406

385

426

492

528

25

538

511

534

578

598

15

640

623

619

623

624

5

702

698

700

687

686

0

709

709

709

709

709

2,000

700

500
400

200

FOOTCANDLE

20

30

50

70 100

1

2

3

4 5

7

10

20

30 40 50

70

100

200

ROOM AREA IN SQUARE FEET

NUMBER OF FIXTURES REQUIRED

300

1,000

100

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

80

70

50

WALL REFLECTANCE

70

50

30

70

50

30

50

30

10

0

81

81

81

73

73

73

57

57

57

1

74

71

68

66

64

61

50

48

47

2

68

63

58

61

56

53

45

42

40

3

63

56

50

56

50

46

40

37

35

4

57

50

44

51

45

40

36

33

30

5

53

45

39

47

40

35

33

29

26

6

49

40

34

44

36

31

30

26

23

7

45

36

30

41

33

28

27

23

20

8

42

33

27

38

30

25

24

21

18

9

39

30

24

35

27

23

22

19

16

10 36

27

22

32

25

20

20

17

14

20% FLOOR CAVITY REFLECTANCE

ROOM CA

VITY RA

TIO

Suspension Length

12"

18"

24"

Footlamberts Above Fixture

121 84.3 67.1

Footlamberts Between Fixtures

20.2 25.2 30.4

Ceiling Brightness Ratio

6.0

3.3

2.2

Reflectances of 80% ceiling, 50% walls and 20% floor.
Light loss factor is .85, Room size is 50' x 50',
Run Spacing 10’. Ceiling Height 9’ to 12’. Values are
taken from the center of the room.

Quick Calculator and Ceiling Brightness

1. Find room area on 

vertical axis.

2.  Move across chart to 

footcandle curve.

3. Move down to 

horizontal axis and 
read number of 
fixtures required.

DISTRIBUTION

Zone

Lumens

% Lamp

% Luminaire

0-90

1331

22.9

28.9

90-180

3271

56.4

71.1

0-180

4602

79.3

100.0

Calculations are for 28 watt T5 lamps, for 54 watt T5 lamps multiply by 1.7

90˚

85˚

95˚

105˚

75˚

65˚

55˚

115˚

125˚

180˚  175˚      165˚        155˚          145˚               135˚

0˚    5˚        15˚           25˚            35˚                 45˚

90˚

750

600

450

300

150

0

150

300

450

600

750

Perfor

m

ance

REPORT NO: 

LRL 299-1E

CAT NO:  

SE24I281WH

LAMPS: 

2 F28T5

LUMENS: 

2900

EFFICIENCY: 

79.3

%

CANDLEPOWER CURVE

Reviews: