Lighting Systems
RT6-11
1BHFPG
-ZUFUVCF*OEJSFDU-JHIU51FS'PPU4FDUJPO
Performance
90˚
85˚
95˚
105˚
75˚
65˚
55˚
115˚
125˚
180˚ 175˚ 165˚ 155˚ 145˚ 135˚
0˚ 5˚ 15˚ 25˚ 35˚ 45˚
600
400
800
200
1000
0
REPORT NO: LRL 489-10G
LAMPS: 1-32WT8
LUMENS: 2900
EFFICIENCY: 76.7%
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
73
73
73
62
62
62
43
43
43
1
63
61
58
54
52
50
37
36
35
2
55
51
48
47
44
41
32
30
29
3
49
43
39
42
37
34
29
26
24
4
43
37
33
37
32
29
25
22
20
5
38
32
28
32
28
24
22
19
17
6
33
28
24
29
24
21
20 17
15
7
30
24
20
26
21
18
18
15
13
8
27
21
18
23
19
15
16
13
11
9
24
19
15
21
17
14
15
12
10
10
22
17
14
19
15
12
13
10
9
20% FLOOR CAVITY REFLECTANCE
ROOM CA
VITY RA
TIO
CANDLEPOWER CURVE
Mounting & Joiner Block Accessories
"L" Joiner Block
RT62-LI
Power Feed End
RT65E
3"
3"
6"
6"
9"
9"
Inline Joiner Block
RT62-ILI
6"
12"
6"
ZONAL LUMEN SUMMARY
ZONE
LUMENS % BARELAMP % LUMINAIRE
0-90
0
0.0
0.0
90-180
2224
76.7
100.0
0-180
2224
76.7
100.0
CANDLEPOWER
180
467
467
467
467
467
175
522
507
468
445
444
165
714
625
458
446
468
155
955
779
428
466
462
145
1047
894
374
399
381
135
946
858
300
310
316
125
795
715
235
239
261
115
669
568
151
180
159
105
359
356
71
84
93
95
31
52
15
7
7
90
0
0
0
0
0
85
0
0
0
0
0
75
0
0
0
0
0
65
0
0
0
0
0
55
0
0
0
0
0
45
0
0
0
0
0
35
0
0
0
0
0
25
0
0
0
0
0
15
0
0
0
0
0
5
0
0
0
0
0
0
0
0
0
0
0
Sample Run
4-FOOT JOINER
8-FOOT JOINER
96" (243.84c
m
)
48" (121.92c
m
)
Di
m
ensions given are both fixture length and
m
ounting distances.
42"
(106.68c
m
)
42"
(106.68c
m
)
42"
(106.68c
m
)
20'-6" (624.84c
m
)
42"
(106.68c
m
)
36"
(91.44c
m
)
4-FOOT MODULE
8-FOOT MODULE
8-FOOT MODULE
3" (7.62c
m
) END SET
3" (7.62c
m
) END SET
9" (22.86c
m
)
Ordering Instructions
Individual Fixtures:
1. Order nu
m
ber of JOINER FIXTURES.
2. Order one END SET CEILING ACCENT per fixture.
Square/Rectangle Patterns:
1. Order appropriate nu
m
ber of JOINER FIXTURES to co
m
plete the pattern size.
2. Order nu
m
ber and type of JOINER BLOCKS required.
3. Order one END SET CEILING ACCENT for each run.
Continuous Rows:
1. Deter
m
ine run length.
2. Order the appropriate nu
m
ber of FIXTURES for the co
m
plete run. Fixtures can
be bolted together and through wired to co
m
plete long runs.
3. Order one END SET CEILING ACCENT for each run.
3” (7.62c
m
) 6“ (15.24c
m
) 9" (22.86c
m
) 12” (30.54c
m
)
9" (22.86c
m
)
12" (30.54c
m
)
12" (30.54c
m
)
ZONE
Deg.
0
22
45
67
90