Lighting Systems
Baselyte-BSL27
Page 2 of 8
3 Light T5 HO Indirect
Lightolier
a Genlyte Company
www.lightolier.com
63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.
Job Information
Type:
Performance
Candlepower Curve
Candlepower Summary
Coefficients of Utilization
Module Lengths & Mounting Distances
Joiner
BSLESW
= suspended standard white
End Set
BSLJS
= suspended joiner
System Components & Accessories
Run Configuration
Run
Length
4’
Module
8’
Module
2’
Module
Joiner
End Set
Mount
Power
Mount*
4’ run
8’ run
2’ run
6’ run
2
2
20’ run
2
24’ run
2
2
28’ run
2
2
3
32’ run
2
2
3
Report No:
2060
Lamps:
F54T5
Lumens per Lamp:
4650
Efficiency:
96.8%
Up:
00.0%
Down:
0.0%
Zonal Lumen Summary
ZONE
LUMENS %BARE LAMP %LUMINAIRE
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
CANDLEPOWER SUMMARY
ZONE
CANDLEPOWER
DEG.
0
22.5
45
67.5
90
180
3645
3645
3645
3645
3645
175
3626
3632
3645
3656
3660
165
3496
3530
3602
3658
3678
155
3251
3330
3488
3627
3674
145
2901
3037
3320
3531
3593
135
2447
2675
3068
3337
3405
125
1917
2261
2722
2976
3046
115
1330
1782
2225
2417
2455
105
717
1164
1495
1515
1547
95
161
311
435
294
324
90
6
7
12
8
9
85
0
0
0
0
0
75
0
0
0
0
0
65
0
0
0
0
0
55
0
0
0
0
0
45
0
0
0
0
0
35
0
0
0
0
0
25
0
0
0
0
0
15
0
0
0
0
0
5
0
0
0
0
0
0
0
0
0
0
0
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
92
92
92
78
78
78
53
53
53
1
80
76
73
68
65
63
46
45
43
2
69
64
59
59
55
51
40
38
36
3
61
54
49
52
47
43
36
32
30
4
53
46
41
46
40
36
31
28
25
5
47
40
35
40
35
30
28
24
21
6
42
35
30
36
30
26
25
21
18
7
38
30
26
32
26
22
22
18
16
8
34
27
22
29
23
19
20
16
13
9
30
24
19
26
21
17
18
14
12
10 28
21
17
24
18
15
16
13
10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP
%LUMINAIRE
0-90
90-180
0-180
13503
13503
0
0
100.0
100.0
0
96.8
96.8
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
92
92
92
78
78
78
53
53
53
1
80
76
73
68
65
63
46
45
43
2
69
64
59
59
55
51
40
38
36
3
61
54
49
52
47
43
36
32
30
4
53
46
41
46
40
36
31
28
25
5
47
40
35
40
35
30
28
24
21
6
42
35
30
36
30
26
25
21
18
7
38
30
26
32
26
22
22
18
16
8
34
27
22
29
23
19
20
16
13
9
30
24
19
26
21
17
18
14
12
10 28
21
17
24
18
15
16
13
10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP
%LUMINAIRE
0-90
90-180
0-180
13503
13503
0
0
100.0
100.0
0
96.8
96.8
Note
: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note
: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.