Lightolier Lighting Systems Baselyte-BSL1 Specification Sheet Download Page 3

Lighting Systems

 

Baselyte-BSL1

Page 3 of 8   

2 Light T8 Direct/Indirect

Lightolier 

a Genlyte Company 

www.lightolier.com

63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470

We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.

Job Information 

Type:

•   65 lbs maximum load
•   Canopy: Diameter of 3 3/4“x 7/32”
•  Cable: 7x7 stranded aircraft cable
•   Supported by T-bar and secured to structure
•   J-Box: 4” square (supplied by others)
•   Fully adjustable vertically at fixture

Mount Type: T-Bar 15/16” (On-Grid)*

Mount Type: T-Bar 9/16” (On-Grid)*

Mount Type: T-Bar 9/16” by 5/16” Slot Grid (On-Grid)*

Supension Length

Non-Power Mount

1-Power Mount

1-Power Mount

2’

4’

8’

12’

  3 Conductor

BSLM6102P13 BSLM6104P13 BSLM6108P13 BSLM6112P13

  4 Conductor

BSLM6102P14 BSLM6104P14 BSLM6108P14 BSLM6112P14

  7 Conductor

BSLM6102P17 BSLM6104P17 BSLM6108P17 BSLM6112P17

Non-Power Mount

BSLM6102N

BSLM6104N

BSLM6108N

BSLM6112N

•   65 lbs maximum load
•   Canopy: Diameter of 3 3/4“x 7/32”
•  Cable: 7x7 stranded aircraft cable
•   Supported by T-bar and secured to structure
•   J-Box: 4” square (supplied by others)
•   Fully adjustable vertically at fixture

•   65 lbs maximum load
•   Canopy: Diameter of 3 3/4“x 7/32”
•  Cable: 7x7 stranded aircraft cable
•   Supported by T-bar and secured to structure
•   J-Box: 4” square (supplied by others)
•   Fully adjustable vertically at fixture

 
 

*

Note

Standard T-bar mounts are currently not available for tegular tile ceilings,  

 

however certain tegular tile / T-bar combinations may be supported by the use of the  

 

slot-grid mount. For more information, please consult factory.

Supension Length

Non-Power Mount

1-Power Mount

1-Power Mount

2’

4’

8’

12’

  3 Conductor

BSLM6202P13 BSLM6204P13 BSLM6208P13 BSLM6212P13

  4 Conductor

BSLM6202P14 BSLM6204P14 BSLM6208P14 BSLM6212P14

  7 Conductor

BSLM6202P17 BSLM6204P17 BSLM6208P17 BSLM6212P17

Non-Power Mount

BSLM6202N

BSLM6204N

BSLM6208N

BSLM6212N

Supension Length

Non-Power Mount

1-Power Mount

1-Power Mount

2’

4’

8’

12’

  3 Conductor

BSLM6302P13 BSLM6304P13 BSLM6308P13 BSLM6312P13

  4 Conductor

BSLM6302P14 BSLM6304P14 BSLM6308P14 BSLM6312P14

  7 Conductor

BSLM6302P17 BSLM6304P17 BSLM6308P17 BSLM6312P17

Non-Power Mount

BSLM6302N

BSLM6304N

BSLM6308N

BSLM6312N

Mounting Options

Summary of Contents for Lighting Systems Baselyte-BSL1

Page 1: ...ipper independently tested to meet stringent safety requirements Electrical All luminaires are factory pre wired to module ends with quick wire connectors Joints Intersections Self aligning joining system with hands free pre joining wire access Labels UL CSA standards Ordering Instructions Individual Fixtures 1 Determine the number of individual modules required 2 Order one end set per module 3 Or...

Page 2: ...5 90 180 1045 1045 1045 1045 1045 175 1040 1038 1038 1035 1037 165 1001 994 1000 1003 1006 155 931 922 942 949 957 145 831 826 863 906 925 135 693 705 788 855 884 125 544 569 700 795 827 115 376 434 596 673 706 105 205 299 448 501 545 95 48 117 187 172 214 90 5 20 35 42 47 85 15 26 42 48 51 75 43 46 55 68 73 65 86 99 86 72 76 55 185 163 155 131 128 45 300 249 227 212 212 35 412 354 314 281 286 25 ...

Page 3: ...anded aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture 65 lbs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7 stranded aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture Note Standard T bar mounts are currently not available for ...

Page 4: ...ength 1 Power Mount 2 4 8 12 3 Conductor BSLM3102P13 BSLM3104P13 BSLM3108P13 BSLM3112P13 4 Conductor BSLM3102P14 BSLM3104P14 BSLM3108P14 BSLM3112P14 7 Conductor BSLM3102P17 BSLM3104P17 BSLM3108P17 BSLM3112P17 2 Power Mount 3 Conductor BSLM3102P23 BSLM3104P23 BSLM3108P23 BSLM3112P23 Non Power Mount BSLM3102N BSLM3104N BSLM3108N BSLM3112N Non Power Mount 1 Power Mount 2 Power Mount Non Power Mount 1...

Page 5: ...tor BSLM1102P23 BSLM1104P23 BSLM1108P23 BSLM1112P23 Non Power Mount BSLM1102N BSLM1104N BSLM1108N BSLM1112N Meets UBC OSHPD and DSA seismic requirements Canopy Diameter of 5 1 4 x 3 4 power Cable 7x7 stranded aircraft cable Mountable on 0º 15º sloped ceiling Optional Chicago Plenum approved version available A4 J Box 4 octogonal box supplied by others Fully vertically adjustable at fixture Max 10 ...

Page 6: ...nce B50 All lamps wired on one circuit plus a battery pack is wired to one lamp A hot lead is connected to the battery pack and would function as a trigger wire when connected to a constant hot by installer Leads for both normal circuit and battery pack are wired to fixture ends 1 Circuit with Emergency Battery Pack EM One 4 section in a one circuit fixture to be wired on a separate thru circuit i...

Page 7: ...Emergency Circuit Night Light EC NL One 4 section in two circuit fixture left right switching to be wired on a separate thru circuit Leads for both normal circuit and EC NL circuit wired to fixture ends All lamps in EC NL section to be wired together Type 4 2cct w EC NL Fixture wired for two circuit Lamps wired for left right switching 2 Circuit Left Right Switching Type 2 2cct Type 9 2cct w 1cct ...

Page 8: ... B switching in alternate 4 sections 2 Circuit A B Switching alternate 4 sections 2 Circuit A B Switching alternate 4 sections with Emergency Circuit Night Light EC NL One 4 section in a two circuit fixture A B switching to be wired on a separate thru circuit Leads for both normal circuit and EC NL circuit wired to fixture ends All lamps in EC NL section to be wired together Type C 2cct w EC NL On...

Reviews: