HP90 Recessed Fluorescent

H9S2GLR214 or 224

Page 2 of 2

Direct/Indirect – 2' x 2' with Acrylic Linear Prismatic Lens

Static, 2 Lamp T5

Ordering Information

Explanation of Catalog Number. Example: H9S2GLR224UNVPG

Options/Accessories

Fusing:

Internal fast blow fusing: SUFFIX:

A

.

Internal slow blow fusing: SUFFIX:

C

.

Drywall Kit:

Order Catalog Number:

FK92X2

.

Electrical Wiring Options:

Consult factory.

For motion or light sensor.

See Folio OA20-10.

Specifications

Performance:

In an installation of 2 lamp 14W luminaires in a room cavity ratio of 1,

with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .86.
To reduce glare the average brightness at 65° shall not exceed 2540 candelas per
square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall
not be less than 75.3%.

Materials: Chassis parts

are die-formed code gauge steel.

Lamp Shield:

Linear prismatic translucent DR acrylic lens.

Specifications (continued)

Finish: Chassis exterior

– baked white acrylic enamel.

Cavity

– baked flat white

acrylic enamel. Phosphate undercoating.

Reflector

– low iridescence specular alu-

minum .95% reflectance.

Electrical:

Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is

within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.

Labels:

I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal
Laws. See: www.lamprecycle.org

Options:

Add appropriate

suffix to catalog

no., ie: (A)

HP90

Direct/Indirect

Recessed

S

Body Style:

S

= Static

2

Fixture

Width

G

Ceiling Type:

Fits both

Standard Grid

and

Slot Grid

L

Acrylic Lens

Lamp:

(By Others)

14

=T5 14W

24

=T5HO 24W

(Nominal 24")

R

Reflector:

Specular

Aluminum

2

Lamp

Quantity

2

=2 Lamp

Ballast Type:

<

10THD

2 Lamp Elec. T5

PG ††

(14 Watt)

2 Lamp Elec. T5HO

PG ††

(24 Watt)

††Program Rapid Start (

UNV

only)

0.0

45.0

90.0

FLUX

0

622

622

622

5

620

620

623

59

15

595

605

614

171

25

548

572

593

264

35

481

521

559

326

45

397

456

507

351

55

299

375

440

333

65

198

184

364

280

75

100

180

226

178

85

21

27

20

35

90

2

2

2

Model No. H9S2GLR214UNVPG

LER = FP - 68.1

IW - 31.1

BF - 1.06

Comparative yearly lighting energy cost per

1000 lumens = $3.53

Report Number: G2010021

Catalog Number: H9S2GLR214UNVPG

Lamps: (2) F14T5

Luminaire: HP90 2' x 2' with linear

prismatic lens.

Ballast: ICN-2S28 Advanced

Report is based on 1200 Lumens per lamp.
Efficiency: 83.2%
CIE Type-Direct-Indirect

Plane:

0-Deg

90-Deg

Spacing Criteria:

1.3

1.4

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

22.800

22.800

CANDELA DISTRIBUTION

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG. 90-DEG.

45

1656.

1902.

2115.

55

1538.

1928.

2263.

65

1382.

1982.

2540.

75

1140.

2051.

2575.

85

711.

917.

677.

LUMINANCE DATA IN CANDELA/SQ. METER

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE

FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

0

1 90 86 82 80 78 75 77 75 73

0

2 81 74 68 70 65 61 67 63 59

0

3 74 65 57 61 55 50 58 54 50

0

4 67 57 49 54 47 43 52 46 42

0

5 62 51 43 48 41 36 46 41 36

0

6 57 45 38 43 37 32 42 36 31

0

7 53 41 34 39 33 28 38 32 28

0

8 49 37 30 36 29 25 35 29 25

0

9 46 34 27 33 27 22 32 26 22

10 43 32 25 30 24 20 29 24 20

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

494

20.6

24.7

0

0-

0

40

820

34.2

41.1

0

0-

0

60

1504

62.7

75.3

0

0-

0

90

1997

83.2

100.0

90-180

000

0

0.0

00

0.0

0

0-180

1997

83.2

100.0

ZONAL LUMEN SUMMARY

Model No. H9S2GLR224UNVPG

LER = FP - 57.2

IW -

.

{

BF - 1.0

Comparative yearly lighting energy cost per

1000 lumens = $4.19

Report Number: G2007082

Catalog Number: H9S2GLR224UNVPG

Lamps: (2) F24T5 HO

Luminaire: HP90 2' x 2' with linear

prismatic lens.

Ballast: QTP2X39-24T5HO/UNV Osram

Report is based on 1760 Lumens per lamp.
Efficiency: 80.3%
CIE Type-Direct-Indirect

Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

1.4

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

22.800

22.800

0.0

45.0

90.0

FLUX

0

894

894

894

5

889

890

893

85

15

852

867

880

245

25

781

818

848

377

35

687

744

800

465

45

547

651

732

499

55

397

538

642

473

65

246

406

527

393

75

114

253

326

246

85

26

37

29

47

90

3

3

3

CANDELA DISTRIBUTION

0

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG. 90-DEG.

45

2081.

2477.

2785.

55

1862.

2523.

3011.

65

1566.

2584.

3354.

75

1185.

2630.

3388.

85

802.

1142.

895.

LUMINANCE DATA IN CANDELA/SQ. METER

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE

FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

0

1 87 83 79 78 75 73 75 72 70

0

2 79 72 66 67 63 59 65 61 58

0

3 71 63 56 59 53 49 57 52 48

0

4 65 55 48 52 46 41 50 45 41

0

5 60 49 42 46 40 35 45 39 35

0

6 55 44 37 42 36 31 40 35 31

0

7 51 40 33 38 32 27 37 31 27

0

8 47 36 29 35 29 24 34 28 24

0

9 44 33 26 32 26 22 31 25 22

10 41 31 24 29 24 20 29 23 20

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

706

20.1

25.0

0

0-

0

40

1171

33.3

41.4

0

0-

0

60

2143

60.9

75.8

0

0-

0

90

2828

80.3

100.0

90-180

000

0

0

0.0

00

0.0

0

0-180

2828

80.3

100.0

ZONAL LUMEN SUMMARY

Voltage:

120, 277 or

UNV

=120-277

H9

Standard HP90

HY

For NYC Code – I.B.E.W. Manufactured

Job Information

Type:

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595

1

1/1

1

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group

Section 5/Folio M32-15 Rev.

C

Reviews: