HP90 Recessed Fluorescent
H9S2GLR214 or 224
Page 2 of 2
Direct/Indirect – 2' x 2' with Acrylic Linear Prismatic Lens
Static, 2 Lamp T5
Ordering Information
Explanation of Catalog Number. Example: H9S2GLR224UNVPG
Options/Accessories
Fusing:
Internal fast blow fusing: SUFFIX:
A
.
Internal slow blow fusing: SUFFIX:
C
.
Drywall Kit:
Order Catalog Number:
FK92X2
.
Electrical Wiring Options:
Consult factory.
For motion or light sensor.
See Folio OA20-10.
Specifications
Performance:
In an installation of 2 lamp 14W luminaires in a room cavity ratio of 1,
with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .86.
To reduce glare the average brightness at 65° shall not exceed 2540 candelas per
square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall
not be less than 75.3%.
Materials: Chassis parts
are die-formed code gauge steel.
Lamp Shield:
Linear prismatic translucent DR acrylic lens.
Specifications (continued)
Finish: Chassis exterior
– baked white acrylic enamel.
Cavity
– baked flat white
acrylic enamel. Phosphate undercoating.
Reflector
– low iridescence specular alu-
minum .95% reflectance.
Electrical:
Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is
within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels:
I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal
Laws. See: www.lamprecycle.org
Options:
Add appropriate
suffix to catalog
no., ie: (A)
HP90
Direct/Indirect
Recessed
S
Body Style:
S
= Static
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens
Lamp:
(By Others)
14
=T5 14W
24
=T5HO 24W
(Nominal 24")
R
Reflector:
Specular
Aluminum
2
Lamp
Quantity
2
=2 Lamp
Ballast Type:
<
10THD
2 Lamp Elec. T5
PG ††
(14 Watt)
2 Lamp Elec. T5HO
PG ††
(24 Watt)
††Program Rapid Start (
UNV
only)
0.0
45.0
90.0
FLUX
0
622
622
622
5
620
620
623
59
15
595
605
614
171
25
548
572
593
264
35
481
521
559
326
45
397
456
507
351
55
299
375
440
333
65
198
184
364
280
75
100
180
226
178
85
21
27
20
35
90
2
2
2
Model No. H9S2GLR214UNVPG
LER = FP - 68.1
IW - 31.1
BF - 1.06
Comparative yearly lighting energy cost per
1000 lumens = $3.53
Report Number: G2010021
Catalog Number: H9S2GLR214UNVPG
Lamps: (2) F14T5
Luminaire: HP90 2' x 2' with linear
prismatic lens.
Ballast: ICN-2S28 Advanced
Report is based on 1200 Lumens per lamp.
Efficiency: 83.2%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.3
1.4
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
22.800
22.800
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG. 90-DEG.
45
1656.
1902.
2115.
55
1538.
1928.
2263.
65
1382.
1982.
2540.
75
1140.
2051.
2575.
85
711.
917.
677.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 90 86 82 80 78 75 77 75 73
0
2 81 74 68 70 65 61 67 63 59
0
3 74 65 57 61 55 50 58 54 50
0
4 67 57 49 54 47 43 52 46 42
0
5 62 51 43 48 41 36 46 41 36
0
6 57 45 38 43 37 32 42 36 31
0
7 53 41 34 39 33 28 38 32 28
0
8 49 37 30 36 29 25 35 29 25
0
9 46 34 27 33 27 22 32 26 22
10 43 32 25 30 24 20 29 24 20
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
494
20.6
24.7
0
0-
0
40
820
34.2
41.1
0
0-
0
60
1504
62.7
75.3
0
0-
0
90
1997
83.2
100.0
90-180
000
0
0.0
00
0.0
0
0-180
1997
83.2
100.0
ZONAL LUMEN SUMMARY
Model No. H9S2GLR224UNVPG
LER = FP - 57.2
IW -
{
.
{
BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $4.19
Report Number: G2007082
Catalog Number: H9S2GLR224UNVPG
Lamps: (2) F24T5 HO
Luminaire: HP90 2' x 2' with linear
prismatic lens.
Ballast: QTP2X39-24T5HO/UNV Osram
Report is based on 1760 Lumens per lamp.
Efficiency: 80.3%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.4
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
22.800
22.800
0.0
45.0
90.0
FLUX
0
894
894
894
5
889
890
893
85
15
852
867
880
245
25
781
818
848
377
35
687
744
800
465
45
547
651
732
499
55
397
538
642
473
65
246
406
527
393
75
114
253
326
246
85
26
37
29
47
90
3
3
3
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG. 90-DEG.
45
2081.
2477.
2785.
55
1862.
2523.
3011.
65
1566.
2584.
3354.
75
1185.
2630.
3388.
85
802.
1142.
895.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 87 83 79 78 75 73 75 72 70
0
2 79 72 66 67 63 59 65 61 58
0
3 71 63 56 59 53 49 57 52 48
0
4 65 55 48 52 46 41 50 45 41
0
5 60 49 42 46 40 35 45 39 35
0
6 55 44 37 42 36 31 40 35 31
0
7 51 40 33 38 32 27 37 31 27
0
8 47 36 29 35 29 24 34 28 24
0
9 44 33 26 32 26 22 31 25 22
10 41 31 24 29 24 20 29 23 20
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
706
20.1
25.0
0
0-
0
40
1171
33.3
41.4
0
0-
0
60
2143
60.9
75.8
0
0-
0
90
2828
80.3
100.0
90-180
000
0
0
0.0
00
0.0
0
0-180
2828
80.3
100.0
ZONAL LUMEN SUMMARY
Voltage:
120, 277 or
UNV
=120-277
H9
Standard HP90
HY
For NYC Code – I.B.E.W. Manufactured
Job Information
Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
1
1/1
1
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group
Section 5/Folio M32-15 Rev.
C