GUARDSMAN
GV4WB332
Page 2 of 2
VANDAL RESISTANT WRAPAROUND, 15-5/16" WIDE, 4' LENGTH
SURFACE FLUORESCENT 3 LAMP, T8 OR T12
Lightolier
a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902
Section 6A/Folio P20-61
Job Information
Type:
OPTIONS & ACCESSORIES
SCREWDRIVER:
For holt head screw. Order Catalog Number
LP156737
.
ELECTRICAL/WIRING OPTIONS
Consult factory
FUSING:
Internal fast-blow fusing.
SUFFIX:
GLR
.
Internal slow-blow fusing.
SUFFIX:
GMF
.
SPECIFICATIONS
PERFORMANCE:
In an installation of 3 lamp 32W luminaires in a room cavity
ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be
less than .81. To reduce glare the VCP shall be not less than 42 either cross-
wise or lengthwise (at 100fc level) and the average brightness at 65° shall not
exceed 2729 candelas per square meter. To control veiling reflections, luminaire
output in the 30°-90° zone shall not be less than 72.8%.
MATERIALS: Chassis parts
are die formed code gauge cold rolled steel.
FINISH:
Multi-stage phosphate treated for maximum corrosion resistance and
finish coat high reflectance baked white enamel.
SPECIFICATIONS (continued)
LENS:
Prismatic lens is 50% DR (impact resistant) and 50% standard acrylic
with a nominal thickness of 1/8", withstands 70 ft. lbs. impact without breaking.
SCREWS:
Tamper resistant holt head screws secure lens to housing.
ELECTRICAL:
Thermally protected class “P” ballast C.B.M. approved, non PCB.
If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS:
I.B.E.W./UL and C-UL.
ORDERING INFORMATION
Explanation of Catalog Number. Example: GV4WB332120O3GLR
Other dimming options. Consult factory.
GV
GUARDSMAN
VANDAL
RESISTANT
4
FIXTURE
LENGTH
WB
FIXTURE
TYPE:
WB
=Wraparound
15-5/16" wide
3
LAMP
QUANTITY
LAMP TYPE/
FIXTURE LENGTH:
32
=T8
34
=T12
(nominal 48")
VOLTAGE:
120 or 277
BALLAST TYPE:
1 & 2 Lamp Mag. T12
LE
20THD
10THD
1 & 2 Lamp Elec. T8
SO*
H
I
*
1-3 Lamp Elec. T8
O3*
H3*
*
Instant Start Standard
OPTIONS:
Add appropriate
suffix to catalog
no, ie: (
GLR
)
coefficient of utilization
pfc
20
pcc
80
70
50
pw
70
50
30
70
50
30
50
30
RCR
0
93
93
93
91
91
91
85
85
1
85
81
79
82
80
77
75
72
2
78
71
67
76
69
65
66
61
3
71
64
56
68
61
56
58
54
4
66
56
50
64
55
48
53
46
5
60
51
44
58
50
42
46
42
6
56
46
39
54
45
38
42
36
7
52
41
34
50
40
34
39
33
8
47
38
30
46
36
30
35
29
9
45
34
28
44
34
28
33
27
10
41
32
26
40
32
26
29
25
typical V.C.P.’s
Room
Mounting Height
Size
Lengthwise
Crosswise
8.5
10
8.5
10
30x30
58
61
52
57
40x40
55
57
47
52
60x30
59
62
56
60
60x60
52
54
42
46
100x100
50
51
37
40
candlepower
angle
end
45
cross
0
2339
2339
2339
5
2340
2337
2331
15
2267
2302
2328
25
2110
2208
2274
35
1876
2053
2133
45
1534
1730
1757
55
866
1020
973
65
474
540
679
75
260
310
453
85
68
184
322
95
0
134
266
105
1
137
205
115
4
94
129
125
8
60
78
135
10
45
60
145
9
34
47
155
9
22
33
165
8
12
17
175
8
7
9
Model No. GV4WB332120O3
LER = FW - 75
IW = 86
BF = 0.93
Comparative yearly lighting energy cost per 1000 lumens = $3.20