background image

Specifications

Housing: 

Extruded aluminum with die-formed aluminum

end caps. No exposed fastener.

Lamping: 

Two T8 fluorescent lamps, as specified. 

Provided by others.

Louver:

Matte silver anodized, parabolic with perforated

reveal along top.

Electrical

Specify 120 volt or 277 volt. 3 conductor, 12 gauge
wire. Color-coded quick connectors allow ease of
connection for joiner modules. For special circuiting,
consult factory. Rapid start, HPF, class “P” ther-
mally protected. PowerSpec

®

HDF dimming ballast

is available.

Mountings

Cable Suspension 

(not shown) – 4 1/2" diameter flat

canopy finished satin aluminum, 1/16" diameter
stainless steel aircraft cable adjustable up to 36",
Adjustable cable gripper with cable adjustment. 

Stem Mounting

(not shown) – 4 1/2" diameter flat

canopy finished chrome. 1/2" diameter stem.
Chrome plate or white finish. Can be cut to length
on job. Self-aligning swivel provides adjustability up
to 38 degrees. The stem assembly shall meet or
exceed the requirements set forth in the State of
California Uniform Building Code for suspended
lighting fixtures installed in seismic zone four. 

Surface 

(not shown) – mounts with standard screws

or fasteners.

Finish

Satin aluminum anodized. Custom colors available,
consult factory.

Options & Accessories

Dual switching, emergency battery packs, fusing available –
consult factory.

Labels

UL, ULc and IBEW.

Mountings

Single Stem – Chrome

S24 = 24" Stem

Cable Assembly – aircraft cable adjustable up to 36"

Single Cable: C36
Single Cable and Cord: CC36
Single Cable and Coiled Cord: CCC36

End Cap Set

CCM2047E

7

1

/

2

"

6"

2

1

3

Specifications

LS6

CCM2047

The CCM is a stylish
and contemporary
fixture specifically
designed to add
distinction to spaces.

Profiles

Architectural 

Round

Square

Recessed

Cove

Accent

Custom

Lightolier Lighting Systems

Lightolier Lighting Systems are modular lighting systems that offer a wide selection of
geometric shapes, architectural profiles, scales and finishes.

High tech interiors require luminaires that have the ability to add
visual distinction to their highly modern and functional appearance.
The CCM utilizes two T8 fluorescent lamps to provide powerful yet
controlled downlighting. A parabolic louver featuring a matte silver
anodized finish controls glare and provides an even distribution of
light. Perforations in the louver add definition to the fixture while
the fluted top offers a clean, controlled look.

The CCM is designed to be mounted individually or in continuous
rows. Color-coded quick connectors allow ease of connection
when mounted in series. Designed to provide value, performance
and easy installation, the CCM meets all the needs of high tech
interiors while providing quality illumination.

Lighting Systems

400

800

1200

1600

0

90˚

45˚

15˚

6"

1

/

2

"

CCM: 2 Lamp T8 Direct

Report No. 2480

CCM-1

: 2 lamp T8 

61.7% efficiency, 5.9% 

94.1% 

Coefficients of Utilization 

% Wall Reflectance

50

30

10

0

73

73

73

1

66

64

62

2

60

57

54

3

54

50

47

4

49

45

41

5

44

40

36

6

40

35

32

7

36

32

28

8

33

28

25

9

29

25

21

10

26

22

19

80% Ceiling Reflectance

20% Floor Reflectance

Room Cavity Ratio

Application Data

Fixture Spacing

Footcandles

Watt /Sq Ft

50’ x 70’ x 8.5’ Space

8’ x 8’ (64 sq ft /fixture)

50

1.0

8’ x 10’ (80 sq ft /fixture)

40

0.8

12’ x 16’ x 8.5’ Space

6’ x 8’ (48 sq ft /fixture)

46

1.3

8’ x 8’ x 8.5’ Space

8’ x 8’ (64 sq ft /fixture)

26

1.0

Reflectances: 80% Ceiling, 50% Wall, 20% Floor

Light Loss Factor = .75 (.88 BF x 8.5)

Style

Length

Ballast & Voltage

48

= 4 foot

E81 

= T8 Electronic 120v

96 

= 8 foot

E82 

= T8 Electronic 277v

HD1 

= T8 PowerSpec HDF Dimming 120v

HD2 

= T8 PowerSpec HDF Dimming 277v

M71 

= T8 Electronic Dimming Ballast 120v

M72 

= T8 Electronic Dimming Ballast 277v

How to order

CCM2047

How to Specify

Style

Type

CCM

2047

Individual Fixtures

1.  Order number of FIXTURES.

2.  Order one END SET.

3. Order two STEM or CABLE

ASSEMBLIES.

Continuous Rows

1. Determine run length.

2.  Order appropriate number of JOINER

FIXTURES to complete the run.

3. Order one END SET per run.

4. Order one CABLE or STEM ASSEMBLY

per JOINER FIXTURE plus one.

5.  For runs that exceed amperage 

limits, order the appropriate number

of CABLE/CORD FEEDS.

How to Order

Example: CCM204748E81

Reviews: