Addressing the Luminaires

When using the DMX control input, you are required to set the base address for 
the unit and configure the luminaires connected to it.

The base address for the supply will be the starting address for the first 
luminaire connected to Output 1. You can also group more than one luminaire 
to the same address or reverse the addressing sequence of the luminaires on 
Output 1.

Setting Base Addresses 

1.  Press and release the UP or DOWN address buttons to step through the base 

address. The address numbers 1 through 170 will appear in the display. Press 
and hold either button to rapidly advance to the desired luminaire number. 
Stop when the desired base number appears on the display. (See Fig. 6.)

3-Digit Display

UP

DOWN

Fig. 6

2.  After selecting a base address, press and hold the UP and DOWN buttons 

simultaneously to enter configuration mode. "CFG" appears in the display. 
(See Fig. 7.)

CONFIGURATION MODE

Fig. 7

  When entering Configuration mode, the unit automatically discovers all lumi-

naires that are connected and addresses them sequentially, beginning with 
the base address on the first luminaire on Output 1 through the last luminaire 
on Output 2. This step ensures that the unit correctly identifies all of the 
luminaires connected to its outputs. 

  After the discovery is complete, two 3-digit numbers are briefly displayed. 

The first digit indicates the output port and the last two digits denote the 
number of luminaires connected to that output. For example, the number 107 
represents 7 luminaires on Output 1, while the number 213 indicates 13 lumi-
naires on Output 2. If there are no luminaires attached to an output, the last 
two digits are 00, as in 200. (See Fig. 8.)

OUTPUT NUMBER OF LIGHTS

EXAMPLE: 13 LIGHTS ON OUTPUT 2

Fig. 8

3.  To exit Configuration mode, press both buttons simultaneously. The base 

address for the unit will appear on the display.

Grouping Luminaire Addresses

CCLPS602P allows you to conserve the total number of luminaire addresses in an 
installation by grouping luminaires together. When you group luminaire address-
es, you can assign multiple luminaires to the same address. The number of lumi-
naires per group is limited to the maximum number of luminaires connected to 
Output 1. (For example, if you have 10 luminaires connected to Output 1 and 12 
luminaires connected to Output 2, the maximum group number is 10.)

To set grouping of luminaire addresses: 

1.  Press and hold the UP and DOWN buttons simultaneously to enter configura-

tion mode. “CFG” appears in the display.

2.  When entering Configuration mode, CCLPS602P automatically discovers all 

luminaires that are connected. 

3.  Use the UP button to set a positive group number (the number of luminaires 

per group), according to the following table. 

Group  

Address

How Luminaires Are Addressed

ALL

ALL luminaires are assigned the selected Base Address. 

If you have 20 luminaires with a Base Address of 1, they are ad-

dressed as follows:

Light #:       1   2   3   4   5   6   7   8   ...    18   19   20

Address:     1   1   1   1   1   1   1   1   ...      1     1     1

1

All luminaires are addressed sequentially, starting with the Base 

Address. If you have 20 luminaires with a Base Address of 1, they are 

addressed as follows: 

Light #:       1   2   3   4   5   6   7   8   ...    18   19   20

Address:     1   2   3   4   5   6   7   8   ...    18   19   20 

2

Every two luminaires are assigned the same address. For example, if 

you have 20 luminaires with a Base Address of 1, they are addressed 

as follows: 

Light #:       1   2   3   4   5   6   7   8   ...    18   19   20

Address:     1   1   2   2   3   3   4   4   ...      9   10   10

3

Every three luminaires are assigned the same address. For example, if 

you have 20 luminaires with a Base Address of 1, they are addressed 

as follows: 

Light #:       1   2   3   4   5   6   7   8   ...    18   19   20

Address:     1   1   1   2   2   2   3   3   ...      6     7     7

4 to 20

...

Note: 

It is recommended that you set your group number to a number that 

evenly divides the number of luminaires connected to Output 1 and you balance 
the number of luminaires on each output. Otherwise, you may have a smaller 
amount of luminaires at the end of each output port that would receive the next 
address.

4.  Use the DOWN button to set reverse addressing.

 

Note: 

CCLPS602P allows you to reverse the addressing sequence on Output 

1 ONLY.

  Using reverse addressing, the last luminaire on Output 1 receives the Base 

Address, and then the addresses are assigned sequentially from the last 
luminaire to the first.

  Reverse addressing is particularly useful if you mount your power supply in 

the center of a linear feed or if you want to feed an installation that uses 
multiple power supplies from each side. Use reverse addressing to chase 
from one end of the luminaire run to the next. (See Fig. 9 for examples.)

  Use the DOWN button to set a "negative" group number, according to the fol-

lowing table. Set a negative group number to use reverse addressing.

Summary of Contents for CCLPS602P

Page 1: ...C and relevant local codes Warning Do not attempt to install or use CCLPS602P until you read and under stand the installation instructions and safety labels Warning Do not use CCLPS602P if power cables are damaged Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules This equipment generates uses and can radiate...

Page 2: ...ring requirements Connecting DMX Data CCLPS602P receives DMX data from and can be controlled by Lightolier s full line of DMX512 controllers or any third party DMX512 controller Plug the data RJ 45 connector from the controller into the DMX IN port To daisy chain DMX data to another CCLPS602P connect a CAT5 cable with RJ 45 connectors between the DMX OUT port of the first unit and the DMX IN port ...

Page 3: ...tiple luminaires to the same address The number of lumi naires per group is limited to the maximum number of luminaires connected to Output 1 For example if you have 10 luminaires connected to Output 1 and 12 luminaires connected to Output 2 the maximum group number is 10 To set grouping of luminaire addresses 1 Press and hold the UP and DOWN buttons simultaneously to enter configura tion mode CFG...

Page 4: ...ta Input Interface Lightolier Lytemode DMX color rotary dial or DMX 512 compatible controllers Data Output Interface 24V Classification Class 2 Listings UL cUL CE PSE Max of Luminaires 12 20 6 36 OUT 1 OUT 2 ENET IN DMX IN DMX OUT CCLPS602P Center Feed Installation Base Address 1 9 2 10 1 2 9 1 20 2 9 1 0 2 9 1 20 Group Address Set to 1 Group Address Set to 1 Example 1 When using a Rainbow Wash wi...

Reviews: