background image

ANGLE

MEAN CP

LUMENS

0

5184

5

4618

439

10

3993

15

3481

982

20

2899

25

2453

1117

30

1843

35

1256

808

40

787

45

407

329

50

98

55

42

48

60

32

65

23

19

70

0

75

0

0

80

0

85

0

0

90

0

**  EFFICIENCY = 62.4%  **

CERTIFIED TEST REPORT NO. 2518FR, DATE: MAR  6, 2004

SC = .7

COMPUTED BY LSI PROGRAM **TEST-LITE**

Calculite

®

HID Surface Cylinder

C7CS-E17VM-OVM

Page 2 of 2

7" Aperture, ED17 (Open or Enclosed) Ceramic Metal Halide Downlight

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504

Job Information

Type:

2,250

3,375

1,125

4,500

30°

30°

60°

3,000

4,500

6,000

60°

30°

60°

30°

60°

2,000

4,000

6,000

8,000

70W ED17 

(OPEN RATED) PHILIPS CMH LAMP-3K, LUMEN RATING = 5700 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH REFLECTOR TRIM

ANGLE

MEAN CP

LUMENS

0

4470

5

4140

392

10

3669

15

3195

902

20

2664

25

2189

999

30

1590

35

1037

677

40

648

45

334

262

50

38

55

7

12

60

1

65

0

0

70

0

75

0

0

80

0

85

0

0

90

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

2292

40.22

70.66

0-40

2969

52.1

91.53

0-60

3243

56.91

99.99

0-90

3244

56.92

100

40-90

274

4.82

8.47

60-90

0

0.01

0.01

90-180

0

0

0

0-180

3244

56.92

100

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

MEAN CD/SQ M        

45

16615

55

435

65

28

75

0

85

0

**  EFFICIENCY = 56.9%  **

CERTIFIED TEST REPORT NO. 2394FR, DATE: FEB 10, 2004

SC = .7

COMPUTED BY LSI PROGRAM **TEST-LITE**

CEILING

80%

70%

50%

30%

WALL

70

50

30

10

50

10

50

10

50

10

RCR

0

.68

.68

.68

.68

.66

.66

.63

.63

.61

.61

.57

1

.65

.64

.63

.61

.63

.60

.60

.59

.58

.57

.54

2

.63

.60

.58

.57

.59

.56

.57

.55

.56

.54

.52

3

.60

.57

.55

.53

.56

.53

.55

.52

.54

.51

.49

4

.58

.54

.52

.50

.54

.49

.52

.49

.51

.48

.47

5

.55

.51

.49

.47

.51

.46

.50

.46

.49

.46

.44

6

.53

.49

.46

.44

.48

.44

.48

.44

.47

.43

.42

7

.51

.46

.43

.41

.46

.41

.45

.41

.45

.41

.40

8

.49

.44

.41

.39

.43

.39

.43

.39

.42

.39

.38

9

.46

.42

.39

.37

.41

.37

.41

.36

.40

.36

.35

10

.44

.39

.37

.34

.39

.34

.39

.34

.38

.34

.34

LUMINAIRE INPUT WATTS = 78

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

100W ED17 

(OPEN RATED) PHILIPS CMH LAMP-3K, LUMEN RATING = 8500 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM 

ANGLE

MEAN CP

LUMENS

0

6144

5

5968

562

10

5465

15

4868

1372

20

4164

25

3520

1602

30

2639

35

1739

1130

40

1080

45

615

485

50

197

55

22

55

60

5

65

0

1

70

0

75

0

0

80

0

85

0

0

90

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

3536

41.6

67.9

0-40

4666

54.9

89.6

0-60

5206

61.25

99.98

0-90

5207

61.27

100

40-90

541

6.37

10.4

60-90

1

0.01

0.02

90-180

0

0

0

0-180

5207

61.27

100

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

MEAN CD/SQ M        

45

30624

55

1340

65

0

75

0

85

0

**  EFFICIENCY = 61.3%  ** 

CERTIFIED TEST REPORT NO. 2396FR, DATE: FEB 10, 2004

SC = .8

COMPUTED BY LSI PROGRAM **TEST-LITE**

CEILING

80%

70%

50%

30%

WALL 70

50

30

10

50

10

50

10

50

10

RCR

0

.73

.73

.73

.73

.71

.71

.68

.68

.65

.65

.61

1

.70

.68

.67

.66

.67

.65

.65

.63

.62

.61

.58

2

.67

.65

.63

.61

.64

.60

.62

.59

.60

.58

.55

3

.64

.61

.58

.56

.60

.56

.59

.55

.57

.54

.53

4

.62

.58

.55

.53

.57

.52

.56

.52

.55

.51

.50

5

.59

.55

.51

.49

.54

.49

.53

.49

.52

.48

.47

6

.57

.52

.49

.46

.51

.46

.50

.46

.50

.46

.45

7

.54

.49

.46

.43

.49

.43

.48

.43

.47

.43

.42

8

.52

.46

.43

.41

.46

.41

.45

.40

.45

.40

.39

9

.49

.44

.40

.38

.43

.38

.43

.38

.42

.38

.37

10

.47

.41

.38

.36

.41

.36

.40

.36

.40

.35

.35

LUMINAIRE INPUT WATTS = 110

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

70W ED17

(ENCLOSED), PHILIPS COATED MH UNSHIELDED. LUMEN RATING = 6000 LMS., AROMAT CAT, CL FINISH REFLECTOR TRIM.

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

2537

42.3

67.82

0-40

3345

55.76

89.41

0-60

3722

62.04

99.48

0-90

3741

62.36

100

40-90

396

6.6

10.59

60-90

19

0.33

0.52

90-180

0

0

0

0-180

3741

62.36

100

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

MEAN CD/SQ M        

45

23288

55

2932

65

2213

75

0

85

0

CEILING

80%   

70%

50%

30%

WALL

70

50

30

10

50

10

50

10

50

10

0

RCR

0

.74

.74

.74

.74

.73

.73

.69

.69

.66

.66

.62

1

.71

.70

.68

.67

.69

.66

.66

.64

.64

.62

.59

2

.68

.66

.64

.62

.65

.61

.63

.60

.61

.59

.56

3

.65

.62

.59

.57

.61

.57

.60

.56

.58

.55

.53

4

.63

.59

.56

.54

.58

.53

.57

.53

.56

.52

.51

5

.60

.56

.52

.50

.55

.50

.54

.49

.53

.49

.48

6

.58

.53

.49

.47

.52

.47

.51

.47

.51

.46

.45

7

.55

.50

.46

.44

.49

.44

.49

.44

.48

.43

.43

8

.52

.47

.44

.42

.47

.41

.46

.41

.45

.41

.40

9

.50

.44

.41

.39

.44

.39

.44

.39

.43

.38

.38

10

.48

.42

.39

.36

.42

.36

.41

.36

.41

.36

.35

LUMINAIRE INPUT WATTS = 78.0

Coefficients of Utilization

100W ED17

(ENCLOSED), PHILIPS COATED MH UNSHIELDED. LUMEN RATING = 9000 LMS., AROMAT, CL FINISH REFLECTOR TRIM.

ANGLE

MEAN CP

LUMENS

0

7771

5

6922

659

10

5985

15

5217

1471

20

4344

25

3675

1672

30

2760

35

1879

1208

40

1176

45

606

490

50

141

55

57

67

60

43

65

30

25

70

0

75

0

0

80

0

85

0

0

90

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

3802

42.25

67.99

0-40

5010

55.68

89.6

0-60

5567

61.86

99.55

0-90

5592

62.14

100

40-90

581

6.46

10.4

60-90

25

0.28

0.45

90-180

0

0

0

0-180

5592

62.14

100

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

MEAN CD/SQ M        

45

34641

55

4040

65

2833

75

0

85

0

**  EFFICIENCY = 62.1%  **

CERTIFIED TEST REPORT NO. 2519FR, DATE: MAR  6, 2004  

SC = .7

COMPUTED BY LSI PROGRAM **TEST-LITE**

CEILING

80%

70%

50%

30%

WALL

70

50

30

10

50

10

50

10

50

10

RCR

0

.74

.74

.74

.74

.72

.72

.69

.69

.66

.66

.62

1

.71

.69

.68

.67

.68

.66

.66

.64

.63

.62

.59

2

.68

.66

.63

.62

.64

.61

.62

.60

.61

.58

.56

3

.65

.62

.59

.57

.61

.57

.60

.56

.58

.55

.53

4

.63

.59

.56

.53

.58

.53

.57

.53

.55

.52

.51

5

.60

.55

.52

.50

.55

.50

.54

.49

.53

.49

.48

6

.57

.53

.49

.47

.52

.47

.51

.47

.50

.46

.45

7

.55

.50

.46

.44

.49

.44

.48

.44

.48

.43

.42

8

.52

.47

.44

.41

.46

.41

.46

.41

.45

.41

.40

9

.50

.44

.41

.39

.44

.39

.43

.39

.43

.38

.37

10

.47

.42

.39

.36

.42

.36

.41

.36

.41

.36

.35

LUMINAIRE INPUT WATTS = 110