background image

100

90

80
70

60

50

40

30
20

10

25

50

75

100

125

150

175

200

225

Area Per Fixture In Square Feet

4 5 6

7

8

9

10

11

12

13

14

15

Center To Center Distance Of Fixtures In Feet

This quick calculator chart determines the number and spacing of 2 It. - 42 Watt PL-T
units with clear reflector: for any level of illumination.

Room Surface Reflectances:

80% Ceiling; 50% Wall; 20% Floor

3200 Lumens Per Lamp

RCR=  1

 (Rm. Width= 10xMtg. Ht. above work plane)

RCR=  5

 (Rm. Width= 2xMtg. Ht. above work plane)

RCR=10

 (Rm. Width= Mtg. Ht. above work plane)

Initial Footcandles

Quick Calculator

Coefficients Of Utilization

% Effective Ceiling Cavity Reflectance

80

70

50

30

10

0

% Wall Reflectance

50 30 10

50 30 10

50 30 10

50 30 10

50 30 10

0

1 .74 .72 .70

.72 .70 .69

.69 .68 .67

.67 .66 .65

.65 .64 .63

.62

2 .67 .64 .61

.66 .63 .61

.64 .61 .59

.62 .60 .58

.60 .58 .57

.56

3 .61 .57 .54

.60 .57 .54

.58 .55 .53

.57 .54 .52

.55 .53 .51

.50

4 .56 .51 .48

.55 .51 .48

.54 .50 .47

.52 .49 .46

.51 .48 .46

.45

5 .51    .46 .43

.50 .46 .43

.49 .45 .42

.48 .44 .42

.47 .44 .41

.40

6 .47 .42 .38

.46 .42 .38

.45 .41 .38

.44 .40 .38

.43 .40 .37

.36

7 .43    .41 .37

.46 .41 .37

.45 .40 .37

.44 .40 .37

.43 .39 .36

.35

8 .39 .35 .31

.39 .34 .31

.38 .34 .31

.37 .34 .31

.37 .33 .31

.30

 9 .36 .32 .28

.36 .31 .28

.35 .31 .28

.35 .31 .28

.34 .31 .28

.27

10 .34 .29 .26

.33 .29 .26

.33 .29 .26

.32 .28 .26

.32 .28 .26

.25

20% Floor Cavity Reflectance

Room  Cavity Ratio

Spacing Ratio: Along=1.4 Across=1.7

Certified Test Report N0. ITL44463
Independent Testing Laboratories, Inc.
Recessed Calculite Downlight 8038CLIF/8242HE120
8" Aperture Specular Clear Reflector
Two Philips 42-Watt Pl-t 42W/4P Triple U-Tube. Compact Fluorescents.
Horizontal Position. Lumen Rating =3200 Lms

Date: Jan 3, 1996
Prepared For: Lightolier, Fall River, MA

Tested According To IES Procedures.
Test Distance Exceeds Five Times the
Greatest Luminous Opening Of Luminaire.

CA NDLE POWER SUMMARY

ANGLE

0.0

45.0

90.0 135.0

180.0

FLUX

0 1800 1800 1800 1800

1800

5 1748 1821 1960 1951

1817

184

15 1695 2065 2423 2380

1892

616

25 1828 2305 2516 2461

2082

1048

35 1505 2016 2330 2138

1821

1264

45 1135 1419 1505 1454

1366

1063

55

49

83

63

53

46

142

65

4

3

3

3

2

3

75

1

1

1

1

1

1

85

0

0

0

0

0

0

90

0

0

0

0

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS

% LAMP %LUMINAIRE

0-30

1847

28.9

42.8

0-40

3112

48.6

72.0

0-60

4316

67.4

99.9

0-90

4320

67.5

100.0

90-180

0

0.0

0.0

0-180

4320

67.5

100.0

** Efficiency = 67.5% **

45

15

90

60

30

0

800

1600

2400

75

45

15

90

60

30

0

700

1400

2100

75

0-deg:

90-deg:

180-deg:

0-deg:

90-deg:

180-deg:

100

90

80

70

60

50

40

30

20

10

25

50

75

100

125

150

175

200

225

Area Per Fixture In Square Feet

4 5 6

7

8

9

10

11

12

13

14

15

Center To Center Distance Of Fixtures In Feet

This quick calculator chart determines the number and spacing of 2 It. - 32 W  PL-T units
with clear reflector: for any level of illumination.
For 26W lamps, multiply F.C. by 0.8.

Quick Calculator

32W

Initial Footcandles

Room Surface Reflectances:

80% Ceiling; 50% Wall; 20% Floor

2400 Lumens Per Lamp

RCR=  1

 (Rm. Width= 10xMtg. Ht. above work plane)

RCR=  5

 (Rm. Width= 2xMtg. Ht. above work plane)

RCR=10

 (Rm. Width= Mtg. Ht. above work plane)

Spacing Ratio: Along=1.4 Across=1.6

Certified Test Report N0. ITL44462
(Based on recessed fixture 8038CLW/8232HE120)
Independent Testing Laboratories, Inc.
Recessed Calculite Downlight 8038CLIF/8232HE120
8" Aperture Specular Clear Reflector
Two Philips 32-Watt 32W/35/4P Triple U-Tube. Compact Fluorescents.
Horizontal Position. Lumen Rating =2400 Lms

CA

NDLE POWER SUMMARY

ANGLE

0.0

45.0

90.0 135.0

180.0 FLUX

0

1499 1499 1499 1499

1499

5

1502 1555 1643 1573

1426

152

15

1546 1829 2017 1862

1330

505

25

1628 2073 2090 1747

1440

844

35

1312 1820 1842 1573

1242 1007

45

823 1034 1242 1222

1181

849

55

31

55

61

58

61

118

65

2

2

3

2

2

3

75

1

1

1

1

1

1

85

0

0

0

0

0

0

90

0

0

0

0

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS %  LAMP

%LUMINAIRE

0-30

1500

31.3

43.1

0-40

2508

52.2

72.1

0-60

3475

72.4

99.9

0-90

3479

72.5

100.0

90-180

0

0.0

0.0

0-180

3479

72.5

100.0

** Efficiency = 72.5% **

Coefficients Of Utilization

% Effective Ceiling Cavity Reflectance

80

70

50

30

10

0

% Wall Reflectance

50 30 10

50 30 10

50 30 10

50 30 10

50 30 10

0

1

79 .77 .75

.78 .76 .74

.75 .73 .72

.72 .71 .70

.69 .68 .68

.66

2

.72 .69 .66

.71 .68 .65

.69 .66 .64

.66 .64 .62

.64 .62 .61

.60

3

.66 .62 .58

.65 .61 .58

.63 .59 .57

.61 .58 .56

.59 .57 .55

.54

4

.60 .55 .52

.59 .55 .51

.58 .54 .51

.56 .53 .50

.55 .52 .49

.48

5

.55 .50 .46

.54 .49 .46

.53 .49 .45

.51 .48 .45

.50 .47 .44

.43

6

.50 .45 .41

.50 .45 .41

.48 .44 .41

.47 .43 .40

.46 .43 .40

.39

7

.46    .41 .37

.46 .41 .37

.45 .40 .37

.44 .40 .37

.43 .39 .36

.35

8

.42 .37 .34

.42 .37 .34

.41 .37 .33

.40 .36 .33

.40 .36 .33

.32

 9

.39 .34 .31

.39 .34 .31

.38 .34 .30

.37 .33 .30

.37 .33 .30

.29

10

.36 .31 .28

.36 .31 .28

.35 .31 .28

.35 .31 .28

.34 .30 .28

.26

20% Floor Cavity Reflectance. For 26W lamps, multiply C.U. by 1.1.

Room  Cavity Ratio

Date: Dec 4, 1995

Tested According To IES Procedures.
Test Distance Exceeds Five Times the
Greatest Luminous Opening Of Luminaire.

42W

800

1600

2400

Calculite

®

Compact Fluorescent Surface Cylinder

CS8232/42

Page 2 of 2

8" Aperture Triple Tube (4-Pin) Ceiling & Wall Mount

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2003 Genlyte Thomas Group LLC (Lightolier Division) • B0303