background image

Calculite

®

HID Downlight

C7E17HW

Page 2 of 2

7" Aperture, ED17 (Enclosed) Ceramic Metal Halide, Wide Beam

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504

Job Information

Type:

2,625

1,750

875

2,750

1,375

4,125

5,500

30°

60°

30°

60°

70W ED17 (ENCLOSED

) PHILIPS COATED MH LAMP. LUMEN RATING = 6000 LMS., ELECTRONIC AROMAT BALLAST, CL FINISH REFLECTOR

ANGLE 0°

45°

90°

0

3661

3661

3661

5

3538

3625

3689

10

3352

3507

3664

15

3017

3262

3524

20

2666

2901

3192

25

2310

2392

2677

30

1684

1780

2031

35

1099

1210

1512

40

704

784

937

45

263

295

316

50

29

34

31

55

5

4

6

60

0

0

0

65

0

0

0

70

0

0

0

75

0

0

0

80

0

0

0

85

0

0

0

90

0

0

0

ZONAL LUMENS AND PERCENTAGES

ZONE LUMENS % LAMP %LUMINAIRE

0-30

2370

39.51

68.49

0-40

3175

52.93

91.77

0-60

3460

57.68

100

0-90

3460

57.68

100

40-90

284

4.75

8.23

60-90

0

0

0

90-180

0

0

0

0-180

3460

57.68

100

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

45°

90°

45

13056

14682

15733

55

276

215

339

65

0

0

0

75

0

0

0

85

0

0

0

**  EFFICIENCY = 57.7%  **

CERTIFIED TEST REPORT NO. 2621FR, DATE: MAY 20, 2004

SC(ALONG) =.9

COMPUTED BY LSI PROGRAM **TEST-LITE**

SC(ACROSS) =1.0

CEILING

80%

70%

50%

30%

WALL

70

50

30

10

50

10

50

10

50

10

RCR

0

.69 .69 .69 .69

.67 .67

.64 .64

.61 .61

.58

1

.66 .65 .63 .62

.63 .61

.61 .59

.59 .58

.55

2

.63 .61 .59 .57

.60 .57

.58 .55

.56 .54

.52

3

.61 .58 .55 .53

.57 .53

.55 .52

.54 .51

.50

4

.58 .55 .52 .50

.54 .49

.53 .49

.52 .48

.47

5

.56 .52 .49 .47

.51 .46

.50 .46

.49 .46

.44

6

.53 .49 .46 .44

.49 .44

.48 .43

.47 .43

.42

7

.51 .46 .43 .41

.46 .41

.45 .41

.44 .40

.40

8

.49 .44 .41 .39

.43 .38

.43 .38

.42 .38

.37

9

.46 .41 .38 .36

.41 .36

.40 .36

.40 .36

.35

10

.44 .39 .36 .34

.39 .34

.38 .34

.38 .34

.33

LUMINAIRE INPUT WATTS = 78.0

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

100W ED17 (ENCLOSED)

PHILIPS COATED MH LAMP. LUMEN RATING = 9000 LMS., ELECTRONIC AROMAT BALLAST, CL REFLECTOR TRIM 

ANGLE0°

45°

90°

0

5488

5488

5488

5

5304

5434

5530

10

5025

5258

5493

15

4523

4890

5284

20

3996

4349

4786

25

3461

3586

4013

30

2524

2667

3044

35

1646

1812

2265

40

1052

1173

1403

45

392

439

471

50

41

47

44

55

4

4

5

60

0

0

0

65

0

0

0

70

0

0

0

75

0

0

0

80

0

0

0

85

0

0

0

90

0

0

0

ZONAL LUMENS AND PERCENTAGES

ZONE LUMENS % LAMP %LUMINAIRE

0-30

3553

39.48

68.56

0-40

4759

52.88

91.84

0-60

5182

57.59

100

0-90

5182

57.59

100

40-90

423

4.7

8.16

60-90

0

0

0

90-180

0

0

0

0-180

5182

57.59

100

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

45°

90°

45

19435

21873

23449

55

230

231

323

65

0

0

0

75

0

0

0

85

0

0

0

**  EFFICIENCY = 57.6%  **

CERTIFIED TEST REPORT NO. 2630FR, DATE: MAY 23, 2004

SC(ALONG) =  .9

COMPUTED BY LSI PROGRAM **TEST-LITE**

SC(ACROSS) = 1.0

CEILING

80%

70%

50%

30%

WALL

70

50

30

10

50

10

50

10

50

10

RCR

0

.69 .69 .69 .69

.67 .67

.64 .64

.61 .61

.58

1

.66 .64 .63 .62

.63 .61

.61 .59

.59 .57

.55

2

.63 .61 .59 .57

.60 .57

.58 .55

.56 .54

.52

3

.61 .57 .55 .53

.57 .53

.55 .52

.54 .51

.50

4

.58 .55 .52 .50

.54 .49

.53 .49

.52 .48

.47

5

.56 .52 .49 .46

.51 .46

.50 .46

.49 .45

.44

6

.53 .49 .46 .44

.48 .44

.48 .43

.47 .43

.42

7

.51 .46 .43 .41

.46 .41

.45 .41

.44 .40

.40

8

.49 .44 .41 .39

.43 .38

.43 .38

.42 .38

.37

9

.46 .41 .38 .36

.41 .36

.40 .36

.40 .36

.35

10

.44 .39 .36 .34

.39 .34

.38 .34

.38 .34

.33

LUMINAIRE INPUT WATTS = 110 

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

3,500

Reviews: