background image

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.

www.lightolier.com © 2009 Philips Group • B0609

Job Information 

Type:

Calculite

®

 HID Downlight

  C4T4VN

Page 2 of 4 

4½" Aperture, 2pc Vertical, T4 Narrow Beam

 ANGLE   MEAN CP   LUMENS

 

2340 

 

2039 

189

  10 

1505 

  15 

1047 

306

  20 

 720 

  25 

 490 

237

  30 

 351 

  35 

 270 

173

  40 

 209 

  45  

 96 

 79

  50 

 6 

  55 

 0 

 1

  60 

 0 

  65 

 0 

 0

  70 

 0 

  75 

 0 

 0

  80 

 0 

  85 

 0 

 0

  90 

 0 

ZONAL LUMENS AND PERCENTAGES

  ZONE  LUMENS  % LAMP  %LUMINAIRE

  0-30 

732 

43.09 

74.35

  0-40 

905 

53.24 

91.87

  0-60 

985 

57.95 

100.0

  0-90 

985 

57.95 

100.0

  40-90 

80 

4.71 

8.13

  60-90 

0.0 

0.0

 90-180 

0.0 

0.0

  0-180 

985 

57.95 

100.00

20W T4 

GE CMH Lamp, Lumen Rating = 1700 LMS, Aromat Electronic Ballast, CL Finish Trim

 1250 

 2500 

LUMINANCE SUMMARY CD. / SQ. M.

    ANGLE   MEAN CD/SQ M

 

45  

13228 

 

 55  

 32 

 

65  

 

75  

 

85  

0

**EFFICIENCY = 58.0%** 

CERTIFIED TEST REPORT NO. 2401FR, DATE: DEC 22, 

2003SC = .4 

COMPUTED BY LSI PROGRAM **TEST-LITE** 

CANDLEPOWER DISTRIBUTION

 ANGLE   MEAN CP   LUMENS

 

3301 

 

2998 

281

  10 

2493 

  15 

1946 

556

  20 

1462 

  25 

1061 

506

  30 

788 

  35 

609 

383

  40 

435 

  45 

185 

158

  50 

10 

  55 

2

  60 

  65 

0

  70 

  75 

0

  80 

  85 

0

  90 

39W T4 

Philips CMH Lamp, Lumen Rating = 3300 LMS, Aromat Ballast, CL Finish Trim

 1750 

 3500 

LUMINANCE SUMMARY CD. / SQ. M.

    ANGLE   MEAN CD/SQ M

 

45  

25548 

 

 55  

 

65  

 

75  

 

85  

0

**EFFICIENCY = 57.2%** 

CERTIFIED TEST REPORT NO. 2400FR, DATE: DEC 22, 2003

SC = .6 

COMPUTED BY LSI PROGRAM **TEST-LITE** 

CANDLEPOWER DISTRIBUTION

ZONAL LUMENS AND PERCENTAGES

  ZONE  LUMENS  % LAMP  %LUMINAIRE

  0-30 

1343 

40.71 

71.2

  0-40 

1726 

52.33 

91.52

  0-60 

1886 

57.17 

100

  0-90 

1886 

57.17 

100

  40-90 

159 

4.85 

8.48

  60-90 

0

 90-180 

0

  0-180 

1886 

57.17 

100

 ANGLE   MEAN CP   LUMENS

 

5645 

 

5314 

498

  10 

4588 

  15 

3673 

1044

  20 

2797 

  25 

2083 

989

  30 

1582 

  35 

1220 

770

  40 

878 

  45 

386 

322

  50 

14 

  55 

3

  60 

  65 

0

  70 

  75 

0

  80 

 

  85 

0

  90 

70W T4 

Philips CMH Lamp, Lumen Rating = 6400 LMS, Aromat Electronic Ballast, CL Finish Trim

 2750 

 5500 

LUMINANCE SUMMARY CD. / SQ. M.

    ANGLE   MEAN CD/SQ M

 

45  

53412 

 

 55  

 

65  

 

75  

 

85  

0

**EFFICIENCY = 57.0%** 

CERTIFIED TEST REPORT NO. 2397FR, DATE: DEC 18, 2003

SC = .6 

COMPUTED BY LSI PROGRAM **TEST-LITE** 

CANDLEPOWER DISTRIBUTION

ZONAL LUMENS AND PERCENTAGES

  ZONE  LUMENS  % LAMP  %LUMINAIRE

   0-30 

2530 

39.54 

69.8

  0-40 

3299 

51.56 

91.02

  0-60 

3625 

56.65 

100

  0-90 

3625 

56.65 

100

  40-90 

325 

5.09 

8.98

  60-90 

0

 90-180 

0

  0-180 

3625 

56.65 

100

625

1250

 

1875

2500

875

1750

2625

3500

1375

2750

4125

 

5500

30°

60°

30°

60°

30°

60°

Coefficients of Utilization

Ceiling

80%

70%

50%

30%

Wall

70

50

30

10

50

10

50

10

50

10

0

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

0

.69 .69 .69 .69

.67

.67

.64 .64

.62 .62

.58

1

.67

.65 .64

.63

.64

.62 .62 .60 .60

.58 .56

2

.64

.62 .60

.59

.61

.58 .59

.57 .58 .55 .54

3 .62

.59

.57 .55 .58 .55

.57 .54 .55 .53

.51

4

.60

.56 .54

.52 .56

.52 .54

.51 .53 .50

.49

5

.57 .54

.51

.49 .53

.49

.52

.48

.51

.48

.47

6

.55

.51

.49

.47

.51

.47 .50

.46

.49

.46

.45

7

.53

.49

.46 .44

.49 .44

.48 .44

.47 .44 .43

8

.51

.47 .44

.42

.46

.42

.46

.42

.45

.42

.41

9

.49

.45

.42

.40 .44

.40 .44

.40

.43

.40 .39

10

.47 .43

.40 .38

.42 .38

.42 .38

.42 .38

.37

LUMINAIRE INPUT WATTS = 23

Coefficients of Utilization

Ceiling

80%

70%

50%

30%

Wall

70

50

30

10

50

10

50

10

50

10

0

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

0

.68 .68 .68 .68

.67

.67

.64 .64

.61

.61

.57

1 .66

.64

.63 .62 .63

.61

.61

.59 .59 .58 .55

2 .63

.61

.59

.57

.60

.57 .58 .56

.57 .55 .53

3

.61

.58 .56 .54

.57 .53 .56

.52 .54

.52 .50

4 .58 .55

.52

.51 .54 .50 .53 .50

.52

.49

.48

5 .56

.52

.49

.47

.52

.47

.51

.47 .50

.46

.45

6

.54 .50

.47

.45

.49

.45

.49 .44

.48 .44 .43

7

.52

.47 .44

.42

.47

.42

.46

.42

.45

.42

.41

8 .50

.45

.42

.40 .44

.40 .44

.40 .43

.40 .39

9

.47 .43

.40 .38

.42 .38

.42

.37

.41

.37 .37

10

.45

.40 .38

.36

.40

.36

.40

.36

.39 .35 .35

LUMINAIRE INPUT WATTS = 44

Coefficients of Utilization

Ceiling

80%

70%

50%

30%

Wall

70

50

30

10

50

10

50

10

50

10

0

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

0

.68 .68 .68 .68

.66 .66 .63 .63

.61

.61

.57

1

.65 .64

.63 .62 .63

.61 .60

.59 .58

.57 .54

2 .63 .60

.59

.57 .59 .56 .58 .55 .56 .54

.52

3 .60

.57 .55 .53 .56 .53 .55

.52 .54

.51

.49

4 .58 .54

.52 .50 .54

.49 .53

.49

.51

.48

.47

5 .55

.51

.49

.47

.51

.46 .50

.46

.49

.46 .44

6

.53

.49

.46 .44

.49 .44

.48 .44

.47 .43

.42

7

.51

.46 .43

.42

.46

.41

.45

.41

.45

.41

.40

8

.49 .44

.41 .39

.43 .39

.43 .39

.43 .39 .38

9

.46

.42 .39

.37

.41

.37

.41

.36

.40

.36 .36

10

.44 .39

.37

.35 .39 .35 .39 .34 .38 .34 .34

LUMINAIRE INPUT WATTS = 78

Reviews: