background image

320W ED28

PHILIPS MH COATED LAMP, LUMEN RATING = 30100 LMS, ADVANCE BALLAST PULSE START MAGNETIC, CL FINISH TRIM

2,750

5,500

8,250

11,000

30°

60°

ANGLE

MEAN CP

LUMENS

0

10325

5

10384

994

10

10573

15

10304

2894

20

9659

25

8898

4099

30

7970

35

7756

4746

40

6738

45

4730

3513

50

1945

55

198

526

60

4

65

0

1

70

0

75

0

0

80

0

85

0

0

90

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

7987

26.54

47.62

0-40

12733

42.3

75.92

0-60

16771

55.72

99.99

0-90

16772

55.72

100

40-90

4039

13.42

24.08

60-90

1

0

0.01

90-180

0

0

0

0-180

16772

55.72

100

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

MEAN CD/SQ M        

45

92020

55

4756

65

0

75

0

85

0

***  EFFICIENCY = 55.7%  ** 

CERTIFIED TEST REPORT NO.  2413FR, DATE: FEB 10, 2004

SC = 1.2

COMPUTED BY LSI PROGRAM **TEST-LITE**

CEILING

80%

70%

50%

30%

WALL

70

50

30

10

50

10

50

10

50

10

RCR

0

.66

.66

.66

.66

.65

.65

.62

.62

.59

.59

.56

1

.63

.62

.60

.59

.60

.58

.58

.56

.56

.54

.52

2

.60

.57

.55

.53

.56

.52

.54

.51

.53

.50

.48

3

.57

.53

.50

.48

.52

.48

.51

.47

.50

.46

.45

4

.54

.49

.46

.44

.49

.43

.48

.43

.46

.43

.41

5

.51

.46

.42

.40

.45

.40

.44

.39

.43

.39

.38

6

.48

.42

.39

.36

.42

.36

.41

.36

.40

.36

.35

7

.45

.39

.35

.33

.39

.33

.38

.33

.37

.32

.31

8

.42

.36

.32

.30

.35

.30

.35

.30

.34

.29

.28

9

.39

.33

.29

.27

.33

.27

.32

.27

.32

.26

.26

10

.36

.30

.27

.24

.30

.24

.29

.24

.29

.24

.23

LUMINAIRE INPUT WATTS =  

370.0

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

400W ED28

G.E. MH COATED LAMP. LUMEN RATING = 35000 LMS, ADVANCE MAGNETIC BALLAST, CL FINISH TRIM

5,000

10,000

15,000

20,000

30°

60°

ANGLE

MEAN CP

LUMENS

0

14097

5

14418

1399

10

15675

15

15612

4282

20

13529

25

11653

5440

30

10175

35

10432

6250

40

8760

45

6008

4499

50

2461

55

137

614

60

0

65

0

0

70

0

75

0

0

80

0

85

0

0

90

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

11120

31.77

49.46

0-40

17370

49.63

77.26

0-60

22483

64.24

100

0-90

22483

64.24

100

40-90

5112

14.61

22.74

60-90

0

0

0

90-180

0

0

0

0-180

22483

64.24

100

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

MEAN CD/SQ M        

45

207807

5

5858

65

0

75

0

85

0

**  EFFICIENCY = 64.2%  **

CERTIFIED TEST REPORT NO. 2521FR, DATE: MAR 14, 2004

SC = 1.1

COMPUTED BY LSI PROGRAM **TEST-LITE**

CEILING

80%

70%

50%

30%

WALL

70

50

30

10

50

10

50

10

50

10

RCR

0

.76

.76

.76

.76

.75

.75

.71

.71

.68

.68

.64

1

.73

.71

.69

.68

.70

.67

.67

.65

.65

.63

.60

2

.69

.66

.64

.61

.65

.61

.63

.59

.61

.58

.56

3

.66

.61

.58

.56

.61

.55

.59

.54

.57

.54

.52

4

.62

.57

.54

.51

.57

.51

.55

.50

.54

.50

.48

5

.59

.53

.49

.46

.53

.46

.51

.46

.50

.45

.44

6

.55

.49

.45

.43

.49

.42

.48

.42

.47

.42

.41

7

.52

.46

.42

.39

.45

.38

.44

.38

.43

.38

.37

8

.49

.42

.38

.35

.42

.35

.41

.35

.40

.35

.34

9

.46

.39

.35

.32

.38

.32

.38

.32

.37

.31

.30

10

.43

.36

.32

.29

.35

.29

.35

.29

.34

.28

.27

LUMINAIRE INPUT WATTS =  

460

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

Calculite

®

HID Downlight

C12E28VW

Page 1 of 2

12" Aperture, ED28 (Enclosed) Metal Halide, Wide Beam

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4

Job Information

Type:

175W ED28 

G.E. MH COATED LAMP, LUMEN RATING = 12900 LMS, ADVANCE MAGNETIC BALLAST, CL FINISH TRIM

1,375

2,750

4,125

5,500

30°

60°

ANGLE

MEAN CP

LUMENS

0

5034

5

5057

489

10

5362

15

5266

1459

20

4701

25

4237

1967

30

3820

35

3715

2249

40

3070

45

2096

1574

50

866

55

85

233

60

2

65

0

1

70

0

75

0

0

80

0

8

5

0

90

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

3915

30.35

49.12

0-40

6164

47.79

77.33

0-60

7970

61.79

99.99

0-90

7971

61.79

100

40-90

1807

14.01

22.67

60-90

0

0

0.01

90-180

0

0

0

0-180

7971

61.79

100

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

MEAN CD/SQ M        

45

72490

55

3628

65

0

75

0

5

0

* **  EFFICIENCY = 61.8%  **

CERTIFIED TEST REPORT NO. 2505FR, DATE: MAR 14, 2004

SC = 1.1

COMPUTED BY LSI PROGRAM **TEST-LITE**

CEILING

80%

70%

50%

30%

WALL

70

50

30

10

50

10

50

10

50

10

RCR

0

.74

.74

.74

.74

.72

.72

.69

.69

.66

.66

.62

1

.70

.68

.67

.65

.67

.64

.64

.62

.62

.60

.58

2

.67

.64

.61

.59

.63

.58

.60

.57

.59

.56

.54

3

.63

.59

.56

.53

.58

.53

.57

.52

.55

.51

.50

4

.60

.55

.52

.49

.54

.49

.53

.48

.52

.48

.46

5

.56

.51

.47

.45

.50

.44

.49

.44

.48

.44

.42

6

.53

.47

.44

.41

.47

.41

.46

.40

.45

.40

.39

7

.50

.44

.40

.37

.43

.37

.42

.37

.42

.36

.35

8

.47

.40

.36

.34

.40

.33

.39

.33

.39

.33

.32

9

.44

.37

.33

.30

.37

.30

.36

.30

.36

.30

.29

10

.41

.34

.30

.27

.34

.27

.33

.27

.33

.27

.26

LUMINAIRE INPUT WATTS =  

205.0

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

250W ED28

PHILIPS MH COATED LAMP, LUMEN RATING = 19475 LMS, UNIVERSAL MAGNETIC BALLAST,  CL FINISH TRIM

2,125

4,250

6,375

8,500

30°

60°

ANGLE

MEAN CP

LUMENS

0

8217

5

8229

788

10

8325

15

8132

2277

20

7546

25

6737

3109

30

5850

35

5457

3333

40

4459

45

3040

2289

50

1286

55

130

348

60

4

65

0

1

70

0

75

0

0

80

0

85

0

0

90

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

6174

31.7

50.84

0-40

9507

48.82

78.28

0-60

12143

62.36

99.99

0-90

12144

62.36

100

40-90

2637

13.54

21.72

60-90

0

0

0.01

90-180

0

0

0

0-180

12144

62.36

100

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

MEAN CD/SQ M        

45

105132

55

5546

65

0

75

0

85

0

**  EFFICIENCY = 62.4%  **

CERTIFIED TEST REPORT NO. 2508FR, DATE: MAR 14, 2004

SC = 1.1

COMPUTED BY LSI PROGRAM  **TEST-LITE*

CEILING

80%

70%

50%

30%

WALL

70

50

30

10

50

10

50

10

50

10

RCR

0

.74

.74

.74

.74

.73

.73

.69

.69

.66

.66

.62

1

.71

.69

.67

.66

.68

.65

.65

.63

.63

.61

.58

2

.67

.64

.62

.60

.63

.59

.61

.58

.59

.57

.54

3

.64

.60

.57

.54

.59

.54

.57

.53

.56

.52

.50

4

.61

.56

.52

.50

.55

.49

.54

.49

.53

.48

.47

5

.57

.52

.48

.45

.51

.45

.50

.45

.49

.44

.43

6

.54

.48

.44

.42

.48

.42

.47

.41

.46

.41

.40

7

.51

.45

.41

.38

.44

.38

.43

.38

.43

.37

.36

8

.48

.41

.37

.35

.41

.34

.40

.34

.40

.34

.33

9

.45

.38

.34

.31

.38

.31

.37

.31

.37

.31

.30

10

.42

.35

.31

.28

.35

.28

.34

.28

.34

.28

.27

LUMINAIRE INPUT WATTS =  

290.0

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%