background image

Lightolier is a Philips group brand

Job Information 

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2011 Philips Group • B0711

Calculite

®

 CFL Open Downlight 

8051

Page 2 of 2 

6" Aperture (2) Quad Tube Horizontal Lamp

Spacing  Ratio:  Along= 1.3  Across=1.6

CERTIFIED TEST REPORT NO. 0053FR COMPUTED BY LSI PROGRAM **TEST-LITE**
CALCULITE 6" DIA. APERTURE RECESSED COMPACT FLOURESCENT OPEN DOWNLIGHT WITH

CLEAR IRIDESCENCE FREE FINISH 2-18W PL-C PHILIPS LAMPS. LUMEN RATING = 1250 LMS.

ROOM  CAVITY RATIO

Coefficients  Of  Utilization

% EFFECTIVE CEILING CAVITY REFLECTANCE

80

70

50

30

10

0

% WALL REFLECTANCE

50 30 10

50 30 10

50 30 10

50 30 10

50 30 10

0

1

.55 .54 .53 .54 .53 .52 .52 .51 .50 .50 .49 .49 .48 .48 .47 .46

2

.51 .49 .47 .50 .48 .47 .48 .47 .46 .47 .46 .45 .46 .45 .44 .43

3

.47 .44 .42 .46 .44 .42 .45 .43 .41 .44 .42 .40 .43 .41 .40 .39

4

.43 .40 .38 .43 .40 .38 .42 .39 .37 .41 .39 .37 .40 .38 .37 .36

5

.40 .37 .34 .39 .36 .34 .39 .36 .34 .38 .35 .34 .37 .35 .33 .32

6

.37 .33 .31 .36 .33 .31 .35 .33 .31 .35 .32 .30 .34 .32 .30 .29

7

.34 .30 .28 .33 .30 .28 .32 .29 .27 .32 .29 .27 .31 .29 .27 .26

8

.31 .27 .25 .30 .27 .25 .30 .27 .25 .29 .26 .24 .29 .26 .24 .23

9

.28 .24 .22 .28 .24 .22 .27 .24 .22 .27 .24 .22 .26 .23 .22 .21

10

.25 .22 .20 .25 .22 .19 .25 .22 .19 .24 .21 .19 .24 .21 .19 .18

20% FLOOR CAVITY REFLECTANCE

CANDLEPOWER SUMMARY

O U T P U T

LUMENS

ANGLE ALONG 22.5

45

67.5 ACROSS

0

588

588

588

588

588

5

585

592

599

605

602

57

10

588

606

622

639

650

15

606

619

640

671

693 181

20

600

602

658

669

701

25

561

586

644

661

678 290

30

541

574

606

634

663

35

497

523

591

614

624 353

40

420

452

510

549

562

45

355

372

402

432

449 296

50

212

219

221

233

241

55

30

32

33

40

45

68

60

6

6

6

6

6

65

4

4

4

4

4

4

70

3

3

3

3

2

75

2

2

2

3

2

2

80

2

1

2

3

2

85

1

1

1

3

2

2

90

1

1

1

4

1

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

528

21.13

42.14

0-40

881

35.26

70.31

0-60

1245

49.82

99.35

0-90

1253

50.15

100.00

40-90

372

14.89

29.69

60-90

8

.33

.65

90-180

0

.00

.00

0-180

1253

50.15

100.00

TESTED ACCORDING TO IES PROCEDURES.  TEST DISTANCE EXCEEDS FIVE TIMES THE

GREATEST LUMINOUS OPENING OF LUMINAIRE.

150

120

60

30

60

30

180

0

800

1200

400

Across

45

Along

90

90

 **  EFFICIENCY = 50.1%  **

**  EFFICIENCY = 50.1%  **

**  EFFICIENCY = 50.1%  **

**  EFFICIENCY = 50.1%  **

**  EFFICIENCY = 50.1%  **

DATE: OCT 10, 1996

Reviews: