READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE

This fixture is intended for installation in accordance with the National Electrical Code and local regulations.  To 

assure full compliance with local codes and regulations, check with your local electrical inspector before 

installation.  To prevent electric shock, turn off electricity at fuse box before proceeding. 

Retain these instructions for maintenance reference.

INSTALLATION PROCEDURE FOR: C4CEX (EXPO) SERIES H.I.D. SURFACE CYLINDER 

INSTRUCTION SHEET NO.

IS:C4CEX

A0604 

Page 1 of 2

 

COMPANY

631 Airport Road, Fall River, MA 02720 

STEP 1:

  Screw OUTLET BOX SCREWS (not provided) to 4” 

octagon outlet box, leaving about ¼” space for engaging the 
MOUNTING PLATE. 
 

STEP 2:  

Pass supply wires into large wire-way hole of MOUNTING 

PLATE.

 

 

STEP 3:  

Position key slots in MOUNTING PLATE onto the heads 

of OUTLET BOX SCREWS; shift housing into place and secure by 
tightening the screws firmly. 
 

STEP 4:  

Make Connections.  Bare Copper and/or green insulation 

wire(s) must be connected to SUPPLY GROUND.  Connect WHITE 
BALLAST LEAD to NUETRAL (WHITE) SUPPLY LEAD.  Connect 
BLACK BALLAST LEAD to HOT SUPPLY LEAD.  Use wire nuts 
(local hardware items).  Place wire nuts into outlet box. 
 

STEP 5:  

Install BALLAST SUPPORT onto MOUNTING PLATE, 

secure with threaded CAP NUTS (DO NOT OVER TORQUE),  
 

STEP 6:  

Install lamp. (Use only T4.5 metal halide lamp with G8.5 

base). 
 

STEP 7:  

Install LAMP BARRIER into the INNER GLASS assembly 

and secure with RETAINING SPRING. 
 

STEP 8:  

Attach the INNER GLASS assembly to the REFLECTOR 

by lining up the pins on the REFLECTOR and the slots on the INNER 
GLASS assembly and turn clockwise until tight. 
 

STEP 9:  

Install OUTER GLASS by positioning over the INNER 

BALLAST ASSEMBLY and secure with three set screws

 

 

STEP 10:  

Position REFLECTOR HOUSING onto center stud, 

secure it with LOCK.  
 

STEP 11:  

Slide the UPPER HOUSING over the OUTER GLASS 

and attach to the INNER BALLAST ASSEMBLY. Secure by twisting 
the housing clockwise until tight. 

  

 

CAUTION:  DO NOT ENERGIZE  
THE LAMP UNTIL  THE FIXTURE  
IS COMPLETELY ASSEMBLED  
AND INSTALLED. 
 
 

MOUNTING PLATE

UPPER HOUSING

BALLAST 
SUPPORT

INNER BALLAST 

ASSEMBLY

CAP NUTS

LAMP BARRIER

REFLECTOR

RETAINING SPRING

OUTER GLASS

INNER GLASS

OUTLET BOX 
SCREWS