background image

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 a Philips Group

Section 3A/Folio H10-10 Rev. A

Job Information  

Type:

Lightolier is a Philips group brand

Belmont Spill Frame  

BESF1X4

Page 2 of 2

Architectural Surface Fluorescent

10-1/2" Wide, 50" Length, 2 Lamp T8

Chassis
Model No. BE1W232UNVH

I

with shielding BESF1X4

LER = FP - 48.0      IW - 58.87      BF - 0.88
Comparative yearly lighting energy cost per

1000 lumens = $5.00

Report Number: G2008131
Lamp: (2) F32T8
Luminaire: 1X4 Belmont Spill Frame
Ballast: ICN-2P32-SC
Report is based on 2850 Lumens per lamp.

Efficiency: 56.3%

CIE Type - Direct
Plane:

0-Deg

90-Deg

Spacing Criteria:

1.3

1.3

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

48.000

9.000

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

3535.

3591.

3657.

55

3445.

3552.

3639.

65

3284.

3497.

3666.

75

2938.

3561.

4171.

85

2346.

6091.

8148.

LUMINANCE DATA IN CANDELA/SQ. METER

Length

Shielding

Chassis

Finish

Lamp

Ballast

10THD

4'

BESF1X4

BE1B232UNVHI

Black

2-T8

1 - 2 Lamp Elec.

HI

4'

BESF1X4

BE1W232UNVHI

White

2-T8

1 - 2 Lamp Elec.

HI

Specifications

Finish: Chassis exterior

–white baked polyester enamel. Cavity- white baked

polyester enamel minimum 86% reflectance. Rust preventative undercoating

Frame: 

Extruded aluminum with soft white polyester powder coat finish.

Lens: 

One-piece vacuum formed white acrylic containing 25% DR with 

decorative trim.

Electrical:

Thermally protected class “P” ballast C.B.M. approved, no PCB.  If

KO is within 3” of ballast, use wire suitable for at least 90°.

Labels: 

I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with
Disposal Laws. 
See: www.lamprecycle.org 

Ordering Information

NOTE:

Chassis and shielding shown are stock items.

BE

Options:

Add appropriate suffix to catalog no.,

ie: (GLR)

Consult factory for additional options

Belmont

Architectural

Fluorescent

1

Fixture Width:

= 10 1/2¨ wide

Body Finish:

= White

= Black

32

Lamp:

(By Others)

32 

= T8 32W

(Nominal 24")

2

Lamp

Quantity

= 2 Lamp T8

UNV

Ballast Type:

<

10THD

1 & 2 Lamp Elec. T8

HI †

(32 Watt)

†Instant Start (

UNV

)

Voltage:

UNV

=120-277

Chase Code:

NOTE:

Chassis and shielding are packed in separate cartons. 

When ordering, enter as separate line items.

0.0

45.0

90.0

FLUX

0

1024

1024

1024

5

1017

1018

1023

97

15

982

986

993

279

25

915

921

929

425

35

818

827

836

519

45

697

708

721

548

55

551

568

582

508

65

387

412

432

407

75

212

257

301

273

85

57

148

198

152

90

20

102

150

CANDELA DISTRIBUTION

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

801

14.1

25.0

0

0-

0

40

1320

23.2

41.1

0

0-

0

60

2375

41.7

74.0

0

0-

0

90

3208

56.3

100.0

90-180

000

0

0.0

00

0.0

0

0-180

3208

56.3

100.0

ZONAL LUMEN SUMMARY

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

0

1 60 57 55 54 52 50 51 50 48

0

2 55 50 45 46 43 40 45 42 39

0

3 50 43 38 41 37 34 39 36 33

0

4 45 38 33 36 32 28 35 31 28

0

5 42 34 29 32 28 24 31 27 24

0

6 38 31 25 29 25 21 28 24 21

0

7 36 28 23 26 22 19 26 22 19

0

8 33 25 20 24 20 17 23 19 17

0

9 31 23 18 22 18 15 22 18 15

10 29 21 17 20 16 14 20 16 14

Reviews: