Basic Lytespan
®
1 Circuit Track
6000
Page 3 of 4
Job Information
Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2012 Philips Group • F0512
Track Mounting and Power Feed Systems
Stem Mounting Kits
Mounts to a 4" or 3" octagon outlet box. Use
two per 2' and 4' track, three per 8' and 12'
track. When making a run of track do not
exceed 4' between stems. Use additional stems
for additional support. Power is fed to the track
with the stem closest to the track feed-in point.
For power feed to Feed Track and Live End, "L",
"T", "X", In-line, and Variable Angle Connectors.
Stem can be field cut.
Not recommended for wall mounting.
18" Stem 48" Stem
Actual length from
ceiling to top of track: 1 7 3/8" 47 3/8"
Stem Extension Kit
Mounts to any stem kit to extend its length
by 48". Cannot be field cut.
Swivel Stem Mounting Kits
Adjusts from 0 to 90. Mounts to a 4" or 3"
octagon outlet box. Use two per 2' and 4' track,
three per 8' and 12' track. When making a run of
track do not exceed 4' between stems. Use
additional stems for additional support. Power is
fed to the track with the stem closest to the track
feed-in point. For power feed to Feed Track and
Live End, "L", "T", "X", In-line, and Variable Angle
Connectors. Can be field cut. 48" stem.
Direct Feed into Connectors
The Live End, "L", "T", "X", In-line, and
Variable Angle Connectors contain a nut with
a 1/2-14 thread to accept a 3/8" or 1/2" (trade
size) electrical connector, 3/8" connector
recommended. Does not require a separate
power feed kit.
Stem Extension
1/2" O.D. Steel
Tube
1/4-18 NPSM
Thread.
Clamp Set
Power Extension Connector
Replaces Dead End Cover at end of track to
permit power continuity around structural
obstacles to another track section.
Accepts same power feed-in kits as Live End.
Through Wall or Column
Track
Power Extention
Connector
Track
Power Extention
Connector
3/8" Connector
Jump
Wall
(Conduit)
Over Beam or Through Beam
3/8"
Connector
Track
Power Extention
Connector
Beam
Jump
Track
Power Extention
Connector
Wall
In-Line Connector
Permits power feed between track units in a
straight run of track. The In-Line Connector is
polarized and pre-wired. KO permits direct
feed with electrical connector.
4-1/8"
Live End
Track Unit
3/8" Connector
(by Others)
Conduit Adaptor
For feeding power to Live End from secure
cable terminating in a 3/8" (trade size)
electrical connector. Conduit must be self
supporting. For use with 6048 and 6046.
7596
Zinc Plate
3/8" Connector (by Others)
Live End
Track Unit
Conduit
Adaptor
3" or 4" Octagon
Outlet Box
(by others)
This end may be
field cut.
Stem 1/4"-18
NPSM Thread
Clamp Set
Track
3" or 4" Octagon
Outlet Box
(by others)
0-90 Ceiling
Slope
This end may be
field cut.
Stem 1/4"-18
NPSM Thread
Clamp Set
Track
Stem mounts to track
not feed connector.
Not recommended for wall mounting.
Stem mounts to track not feed connector.
Matte White
7584
7586
Matte Black
7683
7681
7480
Matte White
7481
Matte Black
7582
Matte White
7680
Matte Black
6054NWH
Matte White
6054NBK
Matte Black
6054NAL
Aluminum
6046NWH
Matte White
6046NBK
Matte Black
6046NAL
Aluminum