background image

6700MS38U

Decorative, Discus, 2D CFL, 1 Lt. 38W

Page 3 of 3

Philips Lightolier

e: [email protected]

t:  (508) 679-8131

w: www.lightolier.com
6700MS38U  May 31, 2011
Specifications are subject to change without notice. 

© Koninklijke Philips Electronics N.V., 2011. All rights reserved.

Job Information 

Type:

3       4        5        6                  7                8                  9                   10

15           30            45           60            75           90          120

  60

  50

  40

  30

  20

  10

AREA PER FIXTURE IN SQUARE FEET

Av

er

age

 Initial F

ootcandles

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET

Use quick calculator chart to determine the spacing of 38 Watt units 

for a desired level of illumination.

ROOM SURFACE REFLECTANCES

80% Ceiling, 50% Walls, 20% Floor

2850 Lumens Per Lamp
Large Room
 (RCR = 1)

Small Room (RCR = 5)

180

150

120

80

90

30

0

300

200

100

ACROSS

45

ALONG

Candlepower summary

Angle Mean CP  LMS

Angle Mean CP LMS

0

346

90

33

5

345

33

95

27

30

10

340

100

24

15

333

94

105

25

27

20

323

110

28

25

311

144

115

32

32

30

296

120

36

35

278

174

125

40

35

40

258

130

43

45

237

183

135

47

36

50

213

140

50

55

187

168

145

51

32

60

160

150

51

65

133

132

155

51

24

70

107

160

52

75

82

88

165

51

14

80

61

170

46

85

45

50

175

40

4

90

33

180

43

Zonal Lumens and Percentages

Zone Lumens %Lamp %Luminaire

0-30

270

9.50

20.83

0-40

445

15.62

34.25

0-60

795

27.93

61.24

0-90

1066

37.41

82.02

40-90

620

21.79

47.77

60-90

270

9.48

20.78

90-180

233

8.20

17.98

0-180

1299

45.60

100.00

**Efficiency = 45.6%**

Coefficients Of Utilization  

% Effective Ceiling Cavity Reflectance - Effective Floor Cavity Reflectance = .20

RC

80

70

50

30

10

0

RW 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

1

.45 .43 .42 .44 .42 .40 .40 .39 .38 .37 .36 .35 .34 .33 .32 .31

2

.40 .37 .34 .38 .35 .33 .35 .33 .31 .33 .31 .29 .30 .29 .27 .26

3

.35 .31 .29 .34 .30 .28 .31 .29 .26 .29 .27 .25 .27 .25 .23 .22

4

.31 .27 .24 .30 .27 .24 .28 .25 .23 .26 .23 .22 .24 .22 .20 .19

5

.28 .24 .21 .27 .23 .20 .25 .22 .20 .23 .21 .19 .22 .19 .18 .17

6

.25 .21 .18 .24 .20 .18 .22 .19 .17 .21 .18 .16 .19 .17 .15 .14

7

.22 .18 .16 .21 .18 .15 .20 .17 .15 .19 .16 .14 .17 .15 .13 .12

8

.20 .16 .14 .19 .16 .13 .18 .15 .13 .17 .14 .12 .16 .14 .12 .11

9

.18 .15 .12 .18 .14 .12 .17 .14 .11 .16 .13 .11 .14 .12 .10 .09

10 .17 .13 .11 .16 .13 .10 .15 .12 .10 .14 .11 .10 .13 .11 .09 .08

Room Ca

vity Ratio

Certified Test Report 

No: 0339FR

Computed by LSI Program

**TEST-LITE**

Date: July 10, 1997

Prepared for:

Lightolier

Fall River, MA

Lightolier Decorative Fixture, Discus, 13 

15

16

" diameter acrylic diffuser, G.E. 38W 2D CFL Lamp, 

Lumen Rating = 2850 LMS, E.S. Ballast #E512D38120D (with heat sink), 120VAC

Tested according to IES procedures. 

Test distance exceeds five times the 

greatest luminous opening of luminaire.

8' 8"

9'

9'

8'

8 fc

9 fc

Spacing Ratio = 1.3

Corridor

6700MS38U

8 fc, average

0.5W/sf

Reviews: