Job Information
Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • E0609
Architectural Decorative
4K35
Page 2 of 2
Pendalux Contemporary 35" Diameter Body 6-26/32/42 Triple Tube
Angle Mean CP Lumens
0
495
5
497
47
10
490
15
480
136
20
468
25
450
208
30
430
35
404
253
40
373
45
340
263
50
304
55
268
240
60
231
65
190
190
70
154
75
118
126
80
85
85
56
68
90
44
Angle Mean CP Lumens
90
44
95
235
347
100
757
105
1311
1339
110
1681
115
1932
1913
120
2163
125
2341
2083
130
2442
135
2546
1973
140
2654
145
2727
1707
150
2764
155
2785
1290
160
2818
165
2679
750
170
2401
175
2363
231
180
2540
CERTIFIED TEST REPORT NO. 4R35642A
COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE
CAT. #4R35642SNU, 35” DIFFUSER
6-42W T/E SYLVANIA LAMPS. LUMEN RATING = 3200 LMS.
3-ADVANCE BALLAST #ICF-2S42-M2-LD, 120 VAC
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
CANDLEPOWER SUMMARY
DATE: MAR. 1, 2001
PREPARED FOR:
LIGHTOLIER, FALL RIVER, MA
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
ROOM
CA
VITY
RA
TIO
ZONAL LUMENS AND PERCENTAGES
ZONE
LUMENS % LAMP %LUMINAIRE
0-30
424
2.22
3.23
0-40
699
3.64
5.31
0-60
1246
6.48
9.47
0-90
1659
8.64
12.62
40-90
1069
5.01
7.31
60-90
414
2.16
3.15
90-180
12631
65.79
95.98
0-180
14269
74.43
100.00
** EFFICIENCY = 74.4% **
80
70
50
30
10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1
.58 .55 .53 .51 .49 .46 .37 .36 .35 .24 .24 .23 .13 .12 .12 .08
2
.51 .47 .43 .44 .41 .38 .32 .30 .28 .21 .20 .19 .11 .10 .10 .07
3
.45 .40 .36 .35 .35 .32 .29 .26 .24 .19 .17 .16 .10 .09 .09 .06
4
.39 .34 .31 .34 .30 .27 .25 .22 .20 .17 .15 .14 .09 .08 .07 .05
5
.34 .30 .26 .31 .26 .23 .22 .20 .17 .15 .13 .12 .08 .07 .06 .04
6
.31 .26 .22 .27 .23 .20 .20 .17 .15 .13 .12 .10 .07 .06 .06 .04
7
.28 .23 .19 .24 .20 .17 .18 .15 .13 .12 .10 .09 .06 .05 .05 .03
8
.25 .20 .17 .22 .18 .15 .16 .13 .11 .11 .09 .08 .06 .05 .04 .03
9
.22 .18 .14 .20 .16 .13 .15 .12 .10 .10 .08 .07 .05 .04 .04 .02
10
.20 .16 .13 .18 .14 .11 .13 .11 .09 .09 .07 .06 .05 .04 .03 .02
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
Features
1. Diffusing Reflector:
White translucent acrylic, 3/16” thick.
2. Inner Dirt Shield:
White translucent acrylic, 1/8” thick.
3. Chassis:
Steel 20 gauge, semi-gloss white powder-coat finish.
4. Suspension:
Swivel (central) stem, 5/8” steel tube. Canopy, steel, 7” Dia.
fastened internally, no exposed hardware. Permits installation on ceilings
with slope of up to 45°. Complies with California Code.
5. Cables:
Reflector Bowl is suspended from a central point on three 1/16”
stainless steel cables.
6. Lampholder:
Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4
lamp base.
7. Flange Trim:
Steel 20 gauge, Plated or Painted finish.
Lamping (by others)
Compact Fluorescent:
Triple Tube, 26, 32, or 42 Watts.
General Electric
Osram/Sylvania
Philips
26W Triple Tube 4-Pin
(Amalgam) Compact
Fluorescent Lamp
F26TBX/*/A/4P
CF26DT/E/IN/*
PL-T26W/*/4P
32W Triple Tube 4-Pin
(Amalgam) Compact
Fluorescent Lamp
F32TBX/*/A/4P
CF32DT/E/IN/*
PL-T32W/*/4P
42W Triple Tube 4-Pin
(Amalgam) Compact
Fluorescent Lamp
F42QBK/*/A/4P
CF42DT/E/IN/*
PL-T42W/*/4P
*Manufacturers’ color temperature designation.
Electrical
Ballast:
Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage
120/277V, Multi-Wattage 26/32/42W.
6 Lamp
26 Watt
32Watt
42Watt
Voltage
120V 277V 120V 277V 120V 277V
Total Input Watts
168
168
210
210
279
279
Max. Line Current
(amps)
2.22
0.96
2.80
1.20
1.20
1.60
Power Factor
>0.98 >0.98 >0.98 >0.98 >0.99 >0.99
Ballast Factor
1.02
1.02
0.96
0.96
0.95
0.95
THD <10% Minimum Starting Temperature: -5˚F/-20˚C
Mounting
Mounts directly to 4” outlet box, using crossbar hanger, supplied.
Labels
cULus Suitable for Damp Locations.
Application Data
35 Inch Diameter
36’ x 36’ x 11’ Space
Luminaire
Spacing: 12’ x 12’
Susp. Dist. 35”
2 Lamps
26W
32W
42W
TTT
TTT
TTT
Illum. (FC) Maint.
28
37
49
Lum.Ratio
8/1
8/1
8/1
Watts/Sq. Ft.
1.15
1.42
1.94
Reflectancies: 80% Ceiling, 50% Walls, 20% Floor.
Light Loss Factor = .75 (.88 BF x .85)