background image

Job Information 

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • E0609

Architectural Decorative

  4K35

Page 2 of 2 

Pendalux Contemporary 35" Diameter Body 6-26/32/42 Triple Tube

Angle  Mean CP  Lumens

495

497 

47

10 

490

15 

480 

136

20 

468

25 

450 

208

30 

430

35 

404 

253

40 

373

45 

340 

263

50 

304

55 

268 

240

60 

231

65 

190 

190

70 

154

75 

118 

126

80 

85

85 

56 

 68

90 

44

Angle  Mean CP  Lumens

90 

44

95 

235 

347

100 

757

105 

1311 

1339

110 

1681

115 

1932 

1913

120 

2163

125 

2341 

2083

130 

2442

135 

2546 

1973

140 

2654

145 

2727 

1707

150 

2764

155 

2785 

1290

160 

2818

165 

2679 

750

170 

2401

175 

2363 

231

180 

2540

CERTIFIED TEST REPORT NO. 4R35642A    

COMPUTED BY LSI PROGRAM **TEST-LITE**

LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE                 

CAT. #4R35642SNU, 35” DIFFUSER              

6-42W T/E SYLVANIA LAMPS. LUMEN RATING = 3200 LMS.                

3-ADVANCE BALLAST #ICF-2S42-M2-LD, 120 VAC

TESTED ACCORDING TO IES PROCEDURES.  TEST DISTANCE EXCEEDS FIVE 

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

CANDLEPOWER SUMMARY

DATE: MAR. 1, 2001
PREPARED FOR:
LIGHTOLIER, FALL RIVER, MA

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD

%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

ROOM

 CA

VITY

 RA

TIO

ZONAL LUMENS AND PERCENTAGES

ZONE 

LUMENS % LAMP %LUMINAIRE

0-30 

424   

2.22 

3.23

0-40 

699   

3.64 

 

5.31

0-60 

1246   

6.48 

 

9.47

0-90 

1659   

8.64 

 

12.62

40-90 

1069   

5.01 

 

7.31

60-90 

414   

2.16 

 

3.15

90-180 

12631 

65.79 

 

95.98

0-180 

14269   

74.43 

 

100.00

**  EFFICIENCY = 74.4%  **

 

80 

70 

50 

30 

10

 

50  30  10     50  30  10   50  30  10   50  30  10   50  30  10    0 

  1 

.58 .55 .53  .51 .49 .46  .37 .36 .35  .24 .24 .23  .13 .12 .12  .08

 

  2 

.51 .47 .43  .44 .41 .38  .32 .30 .28  .21 .20 .19  .11 .10 .10  .07

 

  3 

.45 .40 .36  .35 .35 .32  .29 .26 .24  .19 .17 .16  .10 .09 .09  .06

 

  4 

.39 .34 .31  .34 .30 .27  .25 .22 .20  .17 .15 .14  .09 .08 .07  .05

 

  5 

.34 .30 .26  .31 .26 .23  .22 .20 .17  .15 .13 .12  .08 .07 .06  .04

 

  6 

.31 .26 .22  .27 .23 .20  .20 .17 .15  .13 .12 .10  .07 .06 .06  .04

 

  7 

.28 .23 .19  .24 .20 .17  .18 .15 .13  .12 .10 .09  .06 .05 .05  .03

 

  8 

.25 .20 .17  .22 .18 .15  .16 .13 .11  .11 .09 .08  .06 .05 .04  .03

 

  9 

.22 .18 .14  .20 .16 .13  .15 .12 .10  .10 .08 .07  .05 .04 .04  .02

 

 10 

.20 .16 .13  .18 .14 .11  .13 .11 .09  .09 .07 .06  .05 .04 .03  .02

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

Features

1.  Diffusing Reflector:

 White translucent acrylic, 3/16” thick.

2.  Inner Dirt Shield:

 White translucent acrylic, 1/8” thick.

3.  Chassis:

 Steel 20 gauge, semi-gloss white powder-coat finish.

4.  Suspension:

 Swivel (central) stem, 5/8” steel tube. Canopy, steel, 7” Dia. 

fastened internally, no exposed hardware. Permits installation on ceilings 
with slope of up to 45°. Complies with California Code.

5.  Cables:

 Reflector Bowl is suspended from a central point on three 1/16” 

stainless steel cables.

6.  Lampholder:

 Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4 

lamp base.

7.  Flange Trim:

 Steel 20 gauge, Plated or Painted finish.

Lamping (by others)

Compact Fluorescent:

  Triple Tube, 26, 32, or 42 Watts.

 

General Electric 

Osram/Sylvania 

Philips

 

26W Triple Tube 4-Pin 

(Amalgam) Compact 

Fluorescent Lamp

 

F26TBX/*/A/4P 

CF26DT/E/IN/* 

PL-T26W/*/4P

 

32W Triple Tube 4-Pin  

(Amalgam) Compact 

Fluorescent Lamp

 

F32TBX/*/A/4P 

CF32DT/E/IN/* 

PL-T32W/*/4P

  

42W Triple Tube 4-Pin 

(Amalgam) Compact 

Fluorescent Lamp

 

F42QBK/*/A/4P 

CF42DT/E/IN/* 

PL-T42W/*/4P

*Manufacturers’ color temperature designation.

Electrical

Ballast:

 Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage 

120/277V, Multi-Wattage 26/32/42W.

6 Lamp 

     26 Watt 

  32Watt 

    42Watt

Voltage

 

120V  277V  120V  277V  120V  277V

Total Input Watts

 

168 

168 

210 

210 

279 

279

Max. Line Current

(amps)

 

2.22 

0.96 

2.80 

1.20 

1.20 

1.60

Power Factor

 

>0.98  >0.98  >0.98  >0.98  >0.99  >0.99

Ballast Factor

 

1.02 

1.02 

0.96 

0.96 

0.95 

0.95

THD <10% Minimum Starting Temperature:  -5˚F/-20˚C

Mounting 

Mounts directly to 4” outlet box, using crossbar hanger, supplied.

Labels

cULus   Suitable for Damp Locations.

Application Data

             35 Inch Diameter

36’ x 36’ x 11’ Space

Luminaire 

Spacing: 12’ x 12’

 

 

Susp. Dist. 35”

2 Lamps 

26W 

32W 

42W

 

TTT 

TTT 

TTT

Illum. (FC) Maint. 

28 

37 

49

Lum.Ratio 

8/1 

8/1 

8/1

Watts/Sq. Ft. 

1.15 

1.42 

1.94

Reflectancies: 80% Ceiling, 50% Walls, 20% Floor.
Light Loss Factor = .75 (.88 BF x .85)