Installation Procedure for High Wattage Insulated Ceiling  

 

Frame-In Kits 100IFIC, 1101FIC, 2001FIC

Lightolier 

a Genlyte company 

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • B0607

Read and understand these instructions before installing fixture.

This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and 
regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.

Retain these instructions for maintenance reference.

Fig. A
Frame-In

Fig. B
Wire-In

Fig. C
Swing-Up

Fig. D
Close-In

Fig. E
Snap-On

Fig. F
Push-Up

New Construction

NOTE: I.C. Frame-In Kit may be used in direct contact with insulation.

Warning: Use Only With Lightolier Reflector Trims Marked With I.C. Lamping Information.  

Use of Other Manufacturers’ Trims Voids the Underwriters Laboratories Listing and Could Constitute A Fire Hazard

For Joist Spacing Less Than 16" On Center (To 12" On Center):

•  MOUNTING BAR CHANNELS can be shortened and used as nailing 

legs in tight spaces. Simply remove INNER BAR from holed CHANNEL, 
bend CHANNEL at appropriate point and use extra screw to secure it 
to the joist. (Fig. G)

5 3/4"  2001FR
5 1/4"  1004ICX
5 5/8"  1101FIC

5 7/8"  2001FIC
6 3/8"  1001FIC
6" 

1101FIC

CENTER LINE OF

APERTURE OPENING

HINGED MOUNTING BAR

Note: Integral nail version available

Fig. G

TAB

T-BAR

HINGED BAR ENDS

CHANNEL

TAB

BEND AT TAB

BEND AT HOLE

1.  FRAME-IN (Fig. A)

Locate fixture along joist and line up bottom edge of HINGED MOUNTING BAR 
with the bottom of joist and fasten in place.

For suspended ceilings:

•  Rotate HINGED BAR ENDS to position shown and fully extend bars.
•  Crimp bottom of edge of CHANNEL to prevent rotation of 

HINGED BAR ENDS.

•  Bend NON-HINGED end of mounting bar at featured hole location and 

extend out.

•  Position notched area of MOUNTING BARS onto T-BAR and lock by 

bending TAB underneath T-BAR BEAD as shown.

•  For suspended ceiling, make certain that bottom of Mounting Frame is no 

higher than 1" above ceiling line.