III. Cautions:
* Suitable for indoor use, please place the fog machine on dry ground to avoid moisture environments.
* The fog machine must be horizontally placed on ground, can be also be hang on truss, but the fog lean declining degree should
be less than 15degree.
* Fog machine should be placed in environments of good ventilation, and keep the fog machine away from subject around of
20cm.
* Keep the fog machine from flame and flammable, explosive subject to avoid accident.
* When fog machine is puff smoke, please do not puff at people. People should keep away from fog nozzle at least 60cm to
avoid hot damage to people.
* When the fog oil is running out, please fill more fog oil. If the fog oil runs out without stop working, this will damage the pump
and warmer parts of machine.
* When fill the fog oil to tank, please do not fill more than the tank can accept or, the oil will overflow and cause short circuit.
* Flammable liquid, gas or flavor etc. is not allowed to add to the fog oil.
IV. Problem and maintenance
Maintenance:
Note:
All fog machines are prone to clogging due to the thick consistency of fog liquid and the high temperature
at which it vaporizes. However, a properly maintained fog machine should provide years of reliable use.
Cleaning your fog machine regularly will help reduce costly replacement and repair charges.
Do not allow the fog liquid to become contaminated. After every 40 hours of continuous operation, it is
recommended to run a cleaning solution composed of 80% distilled water and 20% distilled vinegar through the
system to prevent the accumulation of particulate matter in the heating element.
The recommended cleaning regimen is as follows: 1. Empty all fog liquid from the machine. Add cleaning
solution to tank. Plug unit in and begin warm up. 2. Run the unit in a well-ventilated area until the tank is almost
empty. Do not allow the pump to run dry. 3. Replace nozzle. 4. Cleaning is now complete. Refill with fog liquid.
Run the machine briefly to clear any cleaning solution from the pump and heater. 5. Do not operate the fog
machine without liquid at any time.
Storage
1. When storing run distilled water (not tap water) through the system as described in the cleaning regimen
above. This will help avoid any particles condensing inside the pump or heater.
2. It is strongly recommended to test-run the machine on a monthly basis in order to achieve its best fogging
condition. A test-run consists of warming up the machine followed by a few minutes of emission. After that,
follow Step 1 under Storage