9. Connect mains cable to 3-pole terminals block, next lock the cable by tightening the cable
gland with at least 4 Nm of torque.
10. Release cover catch, close the cover. Slightly press the cover against the lock, turn the lock
clockwise.
11. "ATTENTION!
Check tightening and tighten if needed of the mains cable gland’s nut during installation.
LUMINAIRE LIFTING AND CARRYING BY MAINS CABLE IS NOT ALLOWED, it may cause
moist protection failure, cable and luminaire’s internal circuits damage."
These instructions assume expert knowledge corresponding to a completed professional
education as an electrician.
Overall and installation dimensions, mm
1.
CONNECTION SCHEMES
1. Mains connection scheme.
28