LED Neon must always be used in conjunction with a 

certified Bright Light 24V DC power supply.

 

Check the polarity of the connector before inserting the 

front connector and switching on the mains power.

 

To minimise voltage drop and ensure consistent light 

output, position the power supply near to the power 

feed end of the LED Neon, and keep the line as short as 

possible.

 

Ensure to add 20% buffer when selecting a power supply.

 

Ensure your maximum run per power feed adheres to the 

guidelines; 10m when using a single connector, or 20m 

when using both connectors (see specification sheet).

 

Before making any cuts, installation, maintenance, or 

connection, be sure the mains power is disconnected.

 

If essential; cut and connect LED Neon correctly. Any 

incorrect operation can cause damage.

 

All connector joints must be connected correctly to 

achieve connector IP rating.

NEON MICRO ARC | HORIZONTAL BENDING | ELECTRICAL AND PHYSICAL INSTALLATION GUIDE

WIRING DIAGRAM

POWER SUPPLY

DIMMER

optional

black wire: -

red wire: +

24V DC

 

Ensure the supply cord is not subject to mechanical stress

 

Keep 10–20mm distance between the end of the profile and the end mounting piece

 

The bend angle should be less than 15 degrees when installing LED Neon into the profile by hand

PROFILE INSTALLATION REQUIREMENTS

Summary of Contents for NEON MICRO ARC

Page 1: ...to improve modify or update the product designs without prior notice info lightculture com au www lightculture com au NEON MICRO ARC HORIZONTAL BENDING ELECTRICAL AND PHYSICAL INSTALLATION GUIDE DO NOT TWIST THE LIGHT OR BEND AGAINST THE LIGHT SURFACE NEON MICRO ARC HORIZONTAL BEDING CAN BE CURVED AS SHOWN BELOW Avoid bending LED Neon within the first unit units are clearly marked with dashed line...

Page 2: ... your maximum run per power feed adheres to the guidelines 10m when using a single connector or 20m when using both connectors see specification sheet Before making any cuts installation maintenance or connection be sure the mains power is disconnected If essential cut and connect LED Neon correctly Any incorrect operation can cause damage All connector joints must be connected correctly to achiev...

Page 3: ...m au Avoid placing mechanical stress on the front connector cable Do not curl or bend the front connector cable with excessive force Avoid installing the profile less than 10mm from the end mounting piece Install the LED Neon into the profile in one direction don t let it bow in the middle PULL PROFILE INSTALLATION REQUIREMENTS NEON MICRO ARC HORIZONTAL BENDING ELECTRICAL AND PHYSICAL INSTALLATION...

Page 4: ...NNECTOR SUPPLIED AS 1M CABLE DOUBLE POWER FEED FEED 01 FEED 02 NEON MICRO ARC CONNECTIONS SWIVEL CONNECTIONS IP20 SIDE FEED BOTTOM FEED TOP END FEED END CAP WHITE VERTICAL HORIZONTAL BENDING REQUIRES FITTING AT FACTORY LEAD TIMES APPLY FEED CONNECTORS SUPPLIED AS 1M CABLE STANDARD CHECK FOR ALTERNATE LENGTHS SLIMLINE INJECTION MOULDING CONNECTIONS IP67 SIDE END TOP END BOTTOM END 16mm 2m m m m 8 1...

Page 5: ...without prior notice info lightculture com au www lightculture com au CODE ACCESSORY L1 L2 HOLE DIMENSIONS HOLE NUMBER BL LS 4858 PLASTIC AND ALUMINIUM PROFILE 2M 100mm 200mm Ø3 5mm 10 BL LS 4855 PLASTIC AND ALUMINIUM MOUNTING CLIP 35MM 17 5mm Ø3 5mm 1 L1 L2 14 14 7 PLASTIC AND ALUMINIUM PROFILE 2M CLIP NEON MICRO ARC MOUNTING ACCESSORIES ...

Reviews: