Page 1: ...Professional Series www lightwaverf com Boiler Switch Model No JSJSLW920 Instruction Manual...

Page 2: ...99 5 EC R TTE Directive 93 68 EEC CE Marking Directive Standards Applied in order to verify compliance Safety BS EN 60730 1 2011 Health R TTE EN 301 489 1 V1 9 2 2011 09 EN 301 489 3 V1 4 1 2002 08 EN...

Page 3: ...se instructions will then explain how to link the Boiler Switch to the LightwaveRF Home To install the Boiler Switch you must understand how to safely turn off the electricity supply and be comfortabl...

Page 4: ...important to install this product in accordance with the following instructions Failure to do so may void your warranty Off LED When illuminated boiler is off Boost button Temporarily turns on boiler...

Page 5: ...le cover not removed Wiring terminals Tightening Screws Installation Rear view with backplate removed IMPORTANT If conducting an insulation resistance test all LightwaveRF products must be disconnecte...

Page 6: ...PORTANT If you are unsure about how to use any of these tools and materials or any stage of the installation process always consult a qualified electrician or heating engineer Cross head screwdriver F...

Page 7: ...parate wiring centre needs to be accessed make sure that no power is being received If in doubt always consult a qualified electrician Ensure that the Boiler is earthed Never take unnecessary risks if...

Page 8: ...rew holes gently lift the backplate away from the main unit and slide it down Once the hooks are free from their mountings the backplate should slide free Screws Installation Hook Once the backplate h...

Page 9: ...boiler which supplies both a hot water tank and the central heating There is a single motorised valve which distributes heated water to either the hot water tank the heating or both It will usually i...

Page 10: ...oiler will always include a room thermostat RT terminal into which a thermostat can be wired This is where the LightwaveRF Boiler Switch should be connected see next page Optional room thermostat usua...

Page 11: ...mains power from terminals located next to the room thermostat terminal Standard combi setup with LightwaveRF Boiler Switch Existing external thermostat disconnected The Boiler Switch is connected to...

Page 12: ...r Download your boiler manual from the support menu Please continue to follow the general instructions provided here whilst referring to your boiler manual to find the exact location of the appropriat...

Page 13: ...to locate this you must gain access to the boiler wiring centre inside the boiler You should refer to your specific boiler manual to find out how to do this Make sure that you turn off the mains powe...

Page 14: ...RT or in some cases temperature sensor or TS Be aware however that the terminology in some boiler manuals may vary There may be a jumper small loop of cable connecting the two terminals as in the diag...

Page 15: ...Boiler Switch when wall mounted Install 1 combi boiler Prepare the cables The Boiler Switch also needs to take mains power from the boiler This can be routed from live neutral and earth terminals loc...

Page 16: ...le 5 core cable Remember that the terminal arrangement on your boiler may differ so please refer to your specific boiler manual for guidance Room thermostat terminals Normally open common and normally...

Page 17: ...water which is stored in the tank and or circulated in the central heating system A motorised valve allows flow to the tank the radiators or both together A room thermostat controls the flow to the he...

Page 18: ...thermostat s connecting wires and terminals that they are connected to There should be two main switching wires usually white and black In some cases there will also be a neutral connection usually bl...

Page 19: ...2 Y plan Typical wiring for a Y plan setup Room thermostat with neutral wire connection to be replaced by Boiler Switch which requires additional live and earth connections Connecting wires Neutral co...

Page 20: ...oom thermostat terminals and add live neutral and earth as shown in the diagram Remember that the terminal arrangement in your wiring centre may not be identical this is an approximate guide only Room...

Page 21: ...on in larger houses The system boiler produces hot water which is stored in the tank and or circulated in the central heating system Two motorised valves allow flow to the tank the radiators or both t...

Page 22: ...cate the room thermostat s wire connections and terminals that they are connected to There should be two main switching wires usually white and black In some cases there will also be a neutral connect...

Page 23: ...an Typical wiring for an S plan setup Room thermostat with neutral wire connection to be replaced by Boiler Switch which requires additional live and earth connections room thermostat connections Neut...

Page 24: ...oom thermostat terminals and add live neutral and earth as shown in the diagram Remember that the terminal arrangement in your wiring centre may not be identical this is an approximate guide only Room...

Page 25: ...ic diagram below shows the main constituent elements of a multi zone S plan plus system This system resembles the S plan system see previous section but includes multiple motorised valves each control...

Page 26: ...each room thermostat s connecting wires and terminals that they are connected to There will be a connected thermostat for each zone valve present each with two main switching connections usually whit...

Page 27: ...lti zone S plan plus setup Room thermostat 1 with neutral wire connection to be replaced by Boiler Switch which requires additional live and earth connections Connecting wires Neutral connection Room...

Page 28: ...the room thermostat terminals and add live neutral and earth as shown in the diagram Remember that the terminal arrangement in your wiring centre may not be identical this is an approximate guide only...

Page 29: ...te includes two screw holes which allow the plate to be mounted to a wall using suitable screws Once mounted the main unit can be slotted back into place and the screws tightened Once the cable s have...

Page 30: ...ol or separate mode of operation Quick Start Guide Installation If your boiler has an internal timer or clock ensure that it is switched to Always ON or alternatively disabled If there is an internal...

Page 31: ...ur Boiler from your smartphone using the LightwaveRF App This section will show you how to setup the basic functions of the Boiler Switch The following section will show you how to link the Boiler Swi...

Page 32: ...eration Standby button If not connected to a Home Thermostat pressing the Standby button on the Boiler Switch toggles the Boiler on and off Once the Boiler Switch is linked to a Home Thermostat pressi...

Page 33: ...mperature The Boost button A LightwaveRF Heating Handset can be linked to a Boiler Switch via a Home Thermostat Once linked the Standby button on the Handset will toggle between Running and Standby mo...

Page 34: ...on the Home Thermostat Link Ok should appear on the display to indicate a successful link To unlink a Home Thermostat press and release the Linking button on the Boiler Switch and then press the Stand...

Page 35: ...s several TRVs Heating Remote sets house temp Window Trigger open window turns off TRV TRV controls radiator Room by room radiator control Lightwave App control any room from anywhere Boiler Switch tu...

Page 36: ...thout having to get up and alter the thermostat or boiler This can be achieved using the LightwaveRF Home Thermostat Boiler Switch and Heating Remote You can turn the temperature up and down boost the...

Page 37: ...care of your entire home Temperatures can be set for each room or heating zone and heating can be planned week by week and room by room If you have electric radiators you can still achieve this by co...

Page 38: ...iler Switch myself A Yes LightwaveRF products are fully legal to install in your own home Q Is it possible to overload the Switch A 7A max loading applies and should not be exceeded Q Can i link more...

Page 39: ...Specification RF frequency 868 MHz Input 230V Output 7 Amps Warranty 2 year standard warranty Technical Specification...