Light Sky TX0760 User Manual Download Page 12

 

 

Main menu

 menu

 menu

 menu

MENU SETTING

11

DMX

Address

:001-512

Information

Totel time

Power

:****(h)

Lamp on

:****(h)

Lamp

 

hours

Total

:****(h)

Lamp

 

open

:****(h)

Temperature

Board

:000.0

RDM

 

UID

Undistributed

Fan

 

speed/Voltag

Fan1

1:0000

 

RPM

Fan2

2:0000

 

RPM

DMX

 

live

1.Pan

 

(***)

2.Pan

 

 

(***)

3.TILT

 

(***)

4.TILT

 

Fine

 

(***)

5.Fuction

 

(***)

6.Dimmer

(***)

7.Shutter

 

(***)

8.Red

 

(***)

9.Green

 

(***)

10.Blue

 

(***)

11.White

 

(***)

12.Macro

 

(***)

13.ZOOM

 

(***)

System

 

version

XY:V*.**

LED-KZ:V*.**

DIS

 

Board

:V*.**

Return(ESC)

Fan

 

mode

Normal

 

mode

Silent

 

mode

 

 

Personal

Channel mode

HSIC

 

Mode

(

12CH

)

Extended

(

15CH

)

Standard(13CH)

SimpleMode

(

9CH

)

Summary of Contents for TX0760

Page 1: ...E mail n Add No 51 Yunfeng Rd Xinhua Industrial Zone Xinhua Street Huadu District Guangzhou China TX0760ZOOM Please read these user manual carefully before use...

Page 2: ...viced correctly and safely My company disclaims all liability for damage to the fitting or to other property or persons deriving from installation use and maintenance that have not been carried out in...

Page 3: ...ng a potential fire hazard Mounting surface and fire protection Keep all combustible materials at least 20 cm away from the fixture This lighting fixture is for professional use only it is not for hou...

Page 4: ...osion The protection screen lens or ultraviolet screen on the lamp can be damaged to the degree of failure if visible damage such as a crack or deep mark should be replaced The light source in this xt...

Page 5: ...set Automatic chang battery IP could be set without electricity Software upgrade Insert USB upgrade software IP20 protection IP20 Protected against the entry of solid bodies larger than 12mm No protec...

Page 6: ...ft in 6 5 Diameter m ft in 50 Diameter m ft in 3 9 10 0 6 3 7 4 23 3 7 23 1 4 4 7 9 1 29 10 5012 466 10120 941 12376 221 28535 2652 221 21 398 37 102 9 1205 112 1065 99 2235 208 538 50 6558 609 49 5 9...

Page 7: ...power cord 6 425 188 506 300 436 ATTACHMENT AND BODY SIZE...

Page 8: ...support structure of the projector and then connected to the fixing point at the centre of the base 7 Make sure all parts for fixing the projector are in a good state of repair Make sure the point of...

Page 9: ...sure all the devices had been installed with natural operate press the power switch to check whether every thing is working normally L N Ground connection to the eiectricty mains must be carried out...

Page 10: ...put 1 Shield 2 Signal Signal Not connected Not connected 3 1 2 3 DMX input Shield Signal Signal Not connected Not connected 4 5 4 5 The projector all the projectors are together dn t touch each other...

Page 11: ...se LED chip s brightness and wave length can not be produced exactly same by LED factory which would cause the color difference in the LED color fixture To solve the issue LIGHT SKY adopts a calibrati...

Page 12: ...0 RDM UID Undistributed Fan speed Voltag Fan1 1 0000 RPM Fan2 2 0000 RPM DMX live 1 Pan 2 Pan 3 TILT 4 TILT Fine 5 Fuction 6 Dimmer 7 Shutter 8 Red 9 Green 10 Blue 11 White 12 Macro 13 ZOOM System ver...

Page 13: ...FF ON Tilt invert OFF ON Return ESC Language English Chinese Display Back Light Open Auto close 15s Reversal Normal Rota 180 Backlight blink ON OFF Return ESC Main menu menu menu menu Return ESC Dimme...

Page 14: ...an Developer Firmware update Return ESC return ESC DMX ARTNET First DMX ARTNET First ARTNET IP Address Service ARTNET Channel control 5 Fuction 6 Dimmer 7 Shutter 8 Red 9 Green 10 Blue 11 White 12 Mac...

Page 15: ...ARTNET Mask Address Net Address Sub Net Address Net Universe Address return ESC Language English Chinese Reversal Normal Rota 180 Main menu menu menu menu 14...

Page 16: ...mmerSpeed4 96 255 37 6 100 No Fuction 6 0 255 0 100 Dimmer 7 Shutter 0 9 0 3 5 NO Function 10 49 3 9 19 2 Slow closing Fast opening slow fast 50 89 19 6 34 9 Fast closing Slow opening Slow Fast 90 119...

Page 17: ...0 255 0 100 Dimmer 7 Shutter 0 9 0 3 5 NO Function 10 49 3 9 19 2 Slow closing Fast opening slow fast 50 89 19 6 34 9 Fast closing Slow opening Slow Fast 90 119 35 3 46 7 Slow closing Slow open Slow F...

Page 18: ...Speed3 86 95 33 7 37 3 DimmerSpeed4 96 255 37 6 100 No Fuction 6 0 255 0 100 Dimmer 7 Shutter 0 9 0 3 5 NO Function 10 49 3 9 19 2 Slow closing Fast opening slow fast 50 89 19 6 34 9 Fast closing Slow...

Page 19: ...00 No Fuction 6 0 255 0 100 7 Shutter 0 9 0 3 5 NO Function 10 49 3 9 19 2 Slow closing Fast opening slow fast 50 89 19 6 34 9 Fast closing Slow opening Slow Fast 90 119 35 3 46 7 Slow closing Slow op...

Page 20: ...TEM 20170831 B W R P1 P4 P8 P5 U U U U D1 7A 250V 1 J1 7A 250V 1 J2 1 J3 0160 FG2 V1 0 TEM 20170831 B W R P1 P4 P8 P5 U U U U D1 7A 250V 1 J1 7A 250V 1 J2 1 J3 0160 FG2 V1 0 TEM 20170831 B W R P1 P4...

Page 21: ...e down the light Please let the parts cool down 10 minute at least then begin to install 4 Please inspect the lens or other moving parts timing and keep them clear and static If find anything damaged...

Page 22: ...o long or interrupt 3 Please check the control system is not valid check the signal amplifier of chain connected is valid 4 Please check whether the communicate cable is too long or the other equipmen...

Page 23: ...above step by step Please check the belt of the X Y is broken Please check the X Y direction data to the receiver is damage Re projector reset On working the pan tilt couldn t work normally the data w...

Page 24: ...E mail n Add No 51 Yunfeng Rd Xinhua Industrial Zone Xinhua Street Huadu District Guangzhou China...

Reviews: