Light Sky FLY DRAGON IP2021Profile User Manual Download Page 4

The products referred to in this manual conform to the European Community Directives to which
they are subject:
Low Voltage 2014/35/EU
Electromagnetic Compatibility 2014/30/EU

该产品符合欧洲共同体要求,遵守:
低压

2014

/

35

/

EU

电磁兼容性

2014

/

30

/

EU

Protection against explosion

预防炸裂

The protection screen, lens or uv screen on the lamp can be damaged to the degree of failure 
if visible damage, such as a crack or deep mark, should be replaced

灯具上的保护屏、透镜或紫外线屏如果产生可见的损坏,即损坏到失效程度,如产生裂缝或
深痕时,应更换。

The light source in this fixture shall be replaced by the manufacturer or its service agent or 
similar qualification.
Always disconnect from mains before replacing the light.

此灯具内的光源应由制造商或其服务代理商或有类似资格的人来更换
更换光源前,请始终切断电源

Light

 光 源

The maximun temperature that can be reached on the external surface of the fitting,
in a thermally steady state,is 80

℃。

Avoid contact bypersons and materials. 
Allow the fixture to cool for at least 15 minutes before handling. 

在热稳定的状态下,灯具外表面的温度最高点可达

80℃

避免直接接触灯体热表面。
让灯具冷却至少

15

分钟后再处理灯具(问题)

t

c

 

80℃

在开始任何维修工作或清洁灯具之前,必须切断灯具供电电源。

Never look directly into the light source. You risk injury to your retina, which may induce blindness.

请不要眼睛对看光源,它对眼睛网膜的损害可能会导致视盲。

Do not look at LEDs with magnifiers, telescopes, binoculars or similar optical instruments that may 

concentrate the light output.

不要用放大镜、望远镜、双筒望远镜或类似的光学仪器来观察

LED

光源,这些仪器可以集中输出光。

Protection optical radiation

光辐射保护

-3-

Y type connection

 

Y

型连接

  If the external cable or cord of the lamp is damaged, the cable shall be replaced by the manufacturer or its
 service agent or similarly qualified person to avoid danger.

如果此灯具的外部软缆或软线损坏了,该线要由制造商或其服务代理商或有类似资格的人更换,以避免发生危险

Summary of Contents for FLY DRAGON IP2021Profile

Page 1: ...Please read these user manual carefully before use E mail n 43 Address No 43 Yunfeng Road Xiuquan Street Huadu District Guangzhou China IP2021Profile...

Page 2: ...iced correctly and safely My company disclaims all liability for damage to the fitting or to other property or persons deriving from installation use and maintenance that have not been carried out in...

Page 3: ...ial fire hazard Mounting surface and fire protection Keep all combustible materials at least 20 cm away from the fixture 20 This lighting fixture is for professional use only it is not for household u...

Page 4: ...mains before replacing the light Light The maximun temperature that can be reached on the external surface of the fitting in a thermally steady state is 80 Avoid contact bypersons and materials Allow...

Page 5: ...ffect is quite excellent 6 Glass gobos 12 rotating gobos 12 Outside diameter 31 9 mm Image diameter rotating gobo wheelA 25 mm rotating gobo wheel B 26 mm Thickness 1 1 mm Channe Standard channel 44CH...

Page 6: ...is stable before positioning the projector 10 When suspending the fixture ensure that the supporting structure and all hardware used can hold at least 10 times the weight of all the devices they suppo...

Page 7: ...3 CMY color mixing system CMY K Y M C 2 Color wheel 7 olour C Cyan A Cyan B Magenta A Magenta B CTO A CTO B Yellow A Yellow B 1 2 3 4 5 Red Green Blue Orange Turquoise 6...

Page 8: ...50 57 6 57 diameter m 6 diameter m Distance m 1 08 1 61 2 16 4 33 3 26 5 4 10 8 16 2 21 7 43 2 32 5 54 1 6 highlights 57 highlights LUX 483 215 122 29 53 17 13068 6127 3481 890 1552 564 distance spot...

Page 9: ...20 5 10 15 20 25 30 30 25 10 15 20 40 0 30 50 57 6 57 diameter m 6 diameter m Distance m 1 08 1 61 2 16 4 33 3 26 5 4 10 8 16 2 21 7 43 2 32 5 54 1 6 highlights 57 highlights LUX 780 330 185 47 87 28...

Page 10: ...9...

Page 11: ...upport structure of the fixture and then connected to the fixing point at the centre of the base Make sure all parts for fixing the fixture are in a good state of repair Make sure the point of anchora...

Page 12: ...y thing is working normally connection to the eiectricty mains must be carried out by a qualified electrical installer or L N black blue brown yellow green white green Conductor Symbol live neutral gr...

Page 13: ...DMX output 1 Shield 2 Signal Signal Not connected Not connected 3 1 2 3 DMX input Shield Signal Signal Not connected Not connected 4 5 4 5 DMX512 in out signal end out in in 12...

Page 14: ...witch The projector starts resetting the effects At the same time the following information scrolls on the display please refer to the actual material 7 DMX 001 DMX Address DMX Information Personal Ma...

Page 15: ...14...

Page 16: ...15...

Page 17: ...16...

Page 18: ...CHANNEL FUNCTION V1 0 44CH 17 function Open...

Page 19: ...18...

Page 20: ...19...

Page 21: ...20...

Page 22: ...21 CHANNEL FUNCTION V1 0 56CH function Open...

Page 23: ...22...

Page 24: ...23...

Page 25: ...24...

Page 26: ...CIRCUIT CONNECTING DIAGRAM 25...

Page 27: ...ng fire CAUTION Disconnect from mains before starting maintenance operation CLEANING AND MAINTENANCES 1 In order to ensure the fixture could work normally It should be kept clean always The lens shoul...

Page 28: ...le is too long or interrupt Please check the control system is not valid check the signal amplifier of chain connected is valid Please check whether the communicate cable is too long or the other equi...

Page 29: ...ed The fixture shadow is fogging Please check the data on the DMX 512 controller is suitable for the electric focus DMX512 Please check the machenical parts is jamging After cleaning please add some t...

Page 30: ...roken that didn t according to the instruction is not guarantee to keep it in good repair The commentary for all the instruction belongs to the supplier in final No authorize can t copy The informatio...

Reviews: