background image

 
LIGHT PROGRESS

 

STICK-ST [Eng.] 

 

Rev. 2 Oct 2020  

 

Page 

8

 of 

15

 

 

 
 

ELECTRICAL CONNECTIONS 

 
 

We suggest you to let a qualified electrician install this device, following these instructions and the electrical scheme, as 

well as CEI norms. 

 

Before connecting the device to the electrical line, make sure that the labelled data on the device is the same as the 

ones of the electrical line; we remind you that the electrical supply power of this device is 220-240V, 50/60Hz. 

 

Make sure that the electrical system is capable of providing the supply current required by the device (please read the 

label). 

 

The connection to the electrical line needs a multipolar switch. 

 

The connection to the electrical line must be made by the supplied cable. 

 

The use of junction devices in which connection is made via screws, nuts, or other means, is necessary to connect the 

device to the electrical line. 

 

Protect the power supply cable from high temperature, sharp corners, water, oils. 

 

  

 

 

MAINTENANCE 

  

 

 

     

 

  

 

USE 

   

WEAR 

 

 

UV LAMP 

 

PROTECTIVE 

   

PROTECTIVE 

 

   

 

GLOVES 

 

 

GLASSES 

 

  

   

 

 

 

 

 

 

 

 

 

 

Lamp  maintenance  is  very  important  because  the  UV-C  light 

emitted  by  the  source  is  not  visible  to  the  eye,  so,  although 

you  see  the  lamp  ON,  its  germicidal  effect  may  not  be 

sufficient to perform disinfection treatment. 

 

 

Before reaching the lamp, 

ALWAYS

 switch off at the power supply. 

 

If the UV-C lamp gets dirty (or dusty) clean it with a clean cloth and 

alcohol.  Avoid  touching  the  glass  part  with  hands.  To  check  UVC 

lamp life  (number of  hours), of the spare UV lamp please refer to 

table  1(correct  product  code  required).  The  lamp,  once  it  has 

reached  the  timing  for  replacement, 

must  be  replaced

,  this 

operation is carried out as follows: 

• Loosen the nuts on the lamp housing and let them slide 

along the lamp; grab the lamp at the 2 ends and pull it in a 

direction parallel to the lamp. 

 

• Repeat the steps in reverse to insert the new lamp. 

 
 
 

 

TROUBLESHOOTING 

 
 

UV LAMP 

 

See MAINTENANCE. 

 
 

BALLAST 

 

All UV-DIRECT models are supplied with electronic ballasts which guarantees an emission of 15% more if compared 

with  traditional  ballasts.  Furthermore,  lamps  are  not  influenced  by  environment  temperature(<-20°C).  Finally,  the 

switching on is immediate with no starter. For this reason, lamps last longer. 

 

To preserve the original features of original IP protection and isolation class, and to maintain all the characteristics that 

guarantee a long-lasting life of this product, the ballast replacement must be done by qualified technicians verified by 

Light Progress. In case of necessity, please, send the device back to our facility for any kind of repairs. 

 

If this is not possible, you can order the entire power supply conduit for replacement (see Table 1 for code). 

 

Summary of Contents for UV-STICK E2/75H-ST-NX-NT

Page 1: ...GRESS STICK ST Eng Rev 2 Oct 2020 Page 1 of 15 UV STICK E2 75H ST NX NT Germicidal UV C Device for Disinfection by Direct Irradiation Portable on wheels MODELS UV STICK E2 75H ST NX NT UV STICK E2 75H P ST NX NT ...

Page 2: ...that the appliance is switched off and unplugged from the main supply Should the appliance become faulty please contact our authorized Service Centre direct and in case of repairs ask for genuine parts Improper repairs may damage the appliance and place the user at serious risk WARNING Avoid exposure to UV C rays emitted by germicidal lamps even for few seconds as it may cause severe conjunctiviti...

Page 3: ...s be kept available for consultation it must follow the device in case of transfer of ownership and accompany the device until its disposal DISPOSAL Do not dispose of these products as unsorted municipal waste Collect them separately as a special waste and entrust them to specialized waste disposal companies Disposal should be in accordance with Legislative Decree No 151 2005 WEEE Italy or the law...

Page 4: ...gher percentage of UV C rays APPLICATIONS AND RESULTS Each UV STICK series can be installed in any type of environment to achieve a deep disinfection of air and surfaces even those difficult to be reached by traditional systems When turned on there is a strong reduction of microbes in the air and on surfaces For example in 8 minutes at a distance of 3 meters it achieves a 99 reduction of bacteria ...

Page 5: ...anger of overdosing In contrast many chemical treatment methods involve the use of products that are risky and difficult to biodegrade with consequent hazards to human health besides the use of chemical products in contrast to UV C rays could develop resistant microbial forms c PRACTICALITY AND ECONOMY Treatment is immediate and ready to use Maintenance is minimal with low costs of both energy con...

Page 6: ...mble the UV unit to the base with the supplied screw kit Picture 2 We recommend the following assembly procedure Place the base plate vertically like shown on Picture 3 with semicircular side upwards Align the top hole with the corresponding hole on the unit insert the hex head screw then tighten by hand or with the aid of a key Repeat with the bottom hole Picture 4 Pic 2 Pic 3 Pic 4 On the other ...

Page 7: ...ing Ensure Safety Glasses are worn before continuing Insert the plug into the wall socket and turn the device on using the switch on the back of the control unit The green control light of the switch will confirm the activation of main power source It is possible to set treatment duration and ignition delay enabling time to comfortably step back from the device and avoid accidental expositions to ...

Page 8: ...atment Before reaching the lamp ALWAYS switch off at the power supply If the UV C lamp gets dirty or dusty clean it with a clean cloth and alcohol Avoid touching the glass part with hands To check UVC lamp life number of hours of the spare UV lamp please refer to table 1 correct product code required The lamp once it has reached the timing for replacement must be replaced this operation is carried...

Page 9: ...t 253 7 nm with high efficiency lighting Stainless steel body AISI 304 All materials used are tested for resistance to intense UV C rays Waterproof and dust proof IP 55 Control Console IP 20 grounded Powered with electronic ballasts specific for UV C ray lamps Reflector coated in extremely pure mirror bright aluminium Direct protection of the lamp with a stainless steel grid CE mark LVD EMC MD RoH...

Page 10: ... the module it has to be filled up in every part and sent via email to info lightprogress it or via fax to 39 0575 789929 to obtain the RMA number that will authorize the shipments of the goods to Light Progress ware house Only authorized goods will be accepted otherwise it will be refused and sent back to the sender on ex works conditions The packages must be sent on DDP Delivery Duty Paid with p...

Page 11: ...ety of Machinery Guards General Requirements for the Design and construction of fixed and movable guards UNI EN ISO 13849 1 2016 Safety of Machinery Parts of the Control System related to the Safety Part 1 General Design Principles UNI EN ISO 14119 2013 Safety of Machinery Interlocking devices associated with guards Principles for design and selection CEI EN 60204 1 2016 Safety of Machinery Electr...

Page 12: ...LIGHT PROGRESS STICK ST Eng Rev 2 Oct 2020 Page 12 of 15 Circuit scheme UV STICK E2 75H ST NX NT ...

Page 13: ...__________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ __...

Page 14: ..._______________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ _____...

Page 15: ...LIGHT PROGRESS STICK ST Eng Rev 2 Oct 2020 Page 15 of 15 ...