Unpacking
Please check the contents to ensure that the product has been received in good condition.
Laser x 1 unit
I.R. remote control x1 pc
IEC Power Lead x 1pc
Safety Keys x2pcs
If you find any accessory is missing or the product has arrived with any problems, please contact your retailer at once.
This product contains no user-serviceable parts so make no attempt to try to fix or modify this item yourself as this will invalidate
the warranty. We recommend you keep the original package and proof of purchase for any possible replacement or returned
demand.
Setting up
1.
Unpack the laser ensuring all packaging and tape is removed.
2.
Always test the laser before fixing in a permanent location.
3.
Connect the IEC mains plug and switch the rear power switch on.
4.
Insert the safety key and turn to a quarter turn clockwise. At this point ensure that no one is exposed to laser radiation.
5.
Select which mode you want to operate the laser in.
6.
Leave the laser to run for 10 minutes before installing in its location.
Installation
When mounting at height, attach a safety wire to the eyebolt with an independent fixing.
Use the integral mounting bracket with a suitable clamp for stand or truss being fixed to. When mounting directly to ceiling
surfaces, be sure to use adequate fixings for the supporting material.
Connecting to mains, earth wire (ground) must be connected.
Use the supplied IEC lead to connect to the main power supply as follows:
Wire
Connection
International symbol
Brown
Live
L
Blue
Neutral
N
Yellow/Cyan
Earth
For your safety, please kindly pay attention to all of the warnings below:
Always plug in the power plug last and disconnect from the mains when the device is not in use or before cleaning.
Do not install and operate the device in rain or extreme heat, moisture or dusty environments.
This device is for indoor use only and in a dry environment.
Do not switch on immediately. Wait until the unit reaches room temperature.
Do not shake the device and avoid brute force when installing or operating.
Do not use the device during thunderstorms and please disconnect the power.
Do not use solvents or aggressive detergent to clean the device. Use a soft and clean cloth.
Do not modify the device or the connected power cord without authorisation.
Do not stare into the aperture. This product emits hazardous levels of optical radiation and will cause serious injury to the eyes
if viewed at close range.
This product should be securely mounted so that its output emission is always directed away from people and at objects that
are able to reflect emission towards people. In this regard, the separation distances cited in HS(G)95 should be observed.
The symbol
determines the minimum distance from lighted objects. The minimum distance between light-output and
the illuminated surface must be more than 0.5m.