Made in Taiwan
Designed and Engineered in the USA
R HS
o
compliant
5.
Warning!
• Before connecting any AC input electrical wiring to the electric grid make sure to turn OFF power to
all appropriate circuit at the breaker box.
• Insert the AC line input wires and the conduit through the side entrance hole of the junction box.
Install proper electrical fittings at the entrance hole for wire protection. Nominal strip length with (5/8")
15 mm long.
• Connect the AC input line (L) wire to the corresponding marked AC line
(L-BLACK)
wire with a
wire nut. Connect the AC input neutral (N) wire to the corresponding marked AC neutral
(N-WHITE)
wire with a wire nut. Make sure to cap the input ground wire ( ) with a wire nut.
• When all wire connections are completed make sure the fixture has slid in all the way and that all
wires are enclosed underneath the junction box. Close and lock the fixture by rotating it upwards
and pressing the two locking mechanisms inwards then release them to lock the fixture onto the
junction box cover.
INSTALLATION GUIDE
SML500/1000/1500
12-38Watt LED Linear Utility Lighting
05