O-ring Care & Maintenance

O-rings are the critical component that keeps water out of the housing.
Routinely inspect o-rings and replace at least once a year. If your o-rings
are damaged, contact the Light & Motion service department for an o-
ring replacement kit.

Follow these steps for proper o-ring function.
1)

The sealing system used on the rear plate incorporates two o-rings. This is
the most critical area of the housing for maintenance and should be inspected
before every dive.

2)

Make sure the rear plate o-rings and the mating surface on the inside of the
main housing are clean from grit, hair, lint and anything that could
potentially breach the o-ring seal.

3)

After frequent diving or if o-rings appear dirty, remove o-rings and clean the
grooves. To remove o-rings, use finger pressure or the rounded edge of a
plastic card to lift the o-ring out of the groove.

Never use a metal object to remove an o-ring. It will cause
damage to the o-ring and mating surface.

4)

To check o-rings for damage, place the o-ring between the index finger and
thumb. Then pull the o-ring through your fingers, feeling for any debris or
wear.

5)

If o-rings are dirty, it is best to replace them. Washing dirty o-rings with soap
and water is not recommended. Soap breaks down the lubricants and will
compromise the integrity of the seal.

6)

Properly greased o-rings will help maintain sealing integrity and minimize
o-ring degradation. Use enough grease to lubricate the o-ring thoroughly, but
not so much that it will attract additional debris. 

7)

Clean the groove with a lint free swab or the folded edge of a paper towel.

8)

All of the front optic ports for the housing also utilize two o-ring seals. Also
check these seals every time the optic is removed.

Stingray o-ring Replacement Kit part # 802-0134 includes:

Two o-rings for the Rear Plate or Monitor Back and two o-rings for front

optic.

#

Rear Plate o-rings

Monitor Back o-rings.

Optic o-rings

Returning Products for Care

We highly recommend a factory annual service to
maintain proper operation of your Stingray II Housing 

1)

Before returning your Light & Motion product for care, please call or email
our service department for a RMA number.

2)

Ship your product pre-paid freight with the return number printed on the
outside of the box. It is recommended that you keep your shipper’s tracking
number until the product is returned to you.

Warning: Do not ship your camera inside the housing.
Shipping companies may drop your system from up to
three feet which could damage your camera.

Contact Light and Motion

Sales Department:

831-645-1525 • Fax 831-375-2517
[email protected]

Service Department

831-645-1572 • Fax 831-375-2517
[email protected]

Mail:

Light & Motion
300 Cannery Row
Monterey, CA 93940

World Wide Web:

www.uwimaging.com

European Service Center:
Attn: Steve Mawle
The New House Jubilee Lane
Milton under Wynchwood
Chipping Norton  0X7 6EP England
441993832396 (ph.)
441993832707 (fax)
[email protected]

#

"

Summary of Contents for TRV120

Page 1: ......

Page 2: ...hold Periodically refer to the website for instruction revisions http www uwimaging com Hot Tip Important Caution Look for these symbols to help identify special information Caution Caution Caution We hope you have a wonderful underwater experience with Light Motion equipment To increase your enjoyment and the life span of your new gear please take an extra minute to review common errors which wil...

Page 3: ...power cable to the rear of the camcorder 4 Secure the camcorder to the Camera Tray by tightening the Camera Tray Mounting Screw into the tripod mount of the camcorder 5 Remove the camcorder s DC in cover LANC cover and Video Jacks cover 6 Insert the larger front cable into the camcorder s red MIC jack 7 Insert the rear black cable into the camcorder s yellow AUDIO VIDEO jack 8 Insert the rear mult...

Page 4: ...camcorder has been turned off by the MODE OFF switch or if camcorder has automatically shut down 12 Slide Camera Tray forward until Release Button engages 13 Rotate camcorder power switch to Memory Although camcorder Power switch is set to Memory when camcorder initially interfaces with Stingray it will be in Camera mode 14 Replace rear plate A Perform an o ring inspection B Align guide pins into ...

Page 5: ...charged battery in the camcorder 3 Verify operation of all housing controls 4 Check that the front bayonet port is securely engaged and that the latch pin is in the locked position Clean lens if necessary 5 Check that the rear plate o rings are seated correctly and that the rear latches are in the closed and locked position First Time Use All Light and Motion housings are pressure tested prior to ...

Page 6: ...ntegrity and minimize o ring degradation Use enough grease to lubricate the o ring thoroughly but not so much that it will attract additional debris 7 Clean the groove with a lint free swab or the folded edge of a paper towel 8 All of the front optic ports for the housing also utilize two o ring seals Also check these seals every time the optic is removed Stingray o ring Replacement Kit part 802 0...

Page 7: ......

Reviews: