Edition: October 1997
- 4 -
1.2 Installation Instructions
Inverters are defined as build-in units (Safety Precaution IP 20).
The installation dimensions together with the required ventilation clearances are
given in the dimensions tables in the Appendix hereto.
The specified vertical mounting position must be adhered to and free passage of air
to the heat sink unit must be ensured.
If installed in a control cabinet, there must bi suitable ventilation louvres.
In the case of impurities in the cooling air which could affect the functioning of the
Inverter, suitable precautions must be taken, (e.g. provision of a regularly serviced air
filter).
When a control cabinet is used, the individually housed braking resistor, Safety
Precaution IP 20, is to be installed outside the cabinet ((preferably on the top
thereof).
The installation dimensions and ventilation clearances are given in the relevant
dimensions tables in the Appendix.
Summary of Contents for MFC 16 12
Page 12: ...Edition October 1997 12 2 5 3 Switching Sequence Diagramm...
Page 16: ...Edition October 1997 16 4 3 Front View MFC 16 40...
Page 17: ...Edition October 1997 17 4 4 Front View MFC 16 60...
Page 18: ...Edition October 1997 18...
Page 19: ...Edition October 1997 19 4 5 Circuit Wiring Diagram...