STEP 10: (Electrical Connection to POWER UNIT)
1. Have a certified electrician make the electrical connection to the power unit. Use a separate circuit for
each power unit, as shown below in (Figs. 19).
Fig. 18
IMPORTANT! The wiring must comply with local code. Protect each circuit with time delay fuse
or circuit breaker. For
115
V single phase, use
3
0 amp fuse.
WARNING!! Never operate the motor in line voltage less than 208VAC as motor damage may occur.
Fig. 19