PLACE THE LIFETONE HL™ NEXT TO YOUR BED WITH THE SPEAKER FACING THE PILLOW.

Plug in Bed Shaker

Install 4 D Cell

Alkaline Batteries

STEP 1

 - POWERING THE HLAC100™

STEP 2

 - SMOKE ALARM COMPATIBILITY

5. You may plug the bed shaker in on the back of the clock now 

 or at any time after it has been set up. 

1.  Remove the battery door located on the back of your clock.
2.  Insert four D cell alkaline batteries, as shown in the illustration at right, 

 matching the polarity (+ and –) signs in the open compartment.

3.  Replace the battery door securely. 

4.  Plug the Lifetone HLAC100™ into an electrical outlet near your bedside.

NOTE:  

The batteries are for backup in the event of a power outage only.  The HLAC100 is not meant to operate on batteries alone. 

The word “TEST” will now be flashing on the screen.  Go to STEP 2.

Smoke alarm has been detected.

Successful test.  You may

now set the clock.

Press TEST/SILENCE

button to silence alarm.

This important test will determine if your smoke alarms are compatible with the Lifetone HL

.

 

BEEP!

T3 ALARM
  SIGNAL

Press TEST/SILENCE

button to start the test.

BED SHAKER

TEST/SILENCE

TEST/SILENCE

BED SHAKER

Doc# LTQSG100 110831

TEST/SILENCE

BED SHAKER

WARNING! DO NOT COVER

AC POWER

QUICK START GUIDE  

– LIFETONE HL™  BEDSIDE FIRE ALARM AND CLOCK       MODEL HLAC100

HLAC100

4 D Cell Alkaline 

Batteries

Bed Shaker

HLAC100 User’s Manual

Thank you for purchasing the Lifetone HL   Bedside Fire Alarm and Clock.  These items are included: 

  ™ 

 

KEEP THIS QUICK-START GUIDE IN A SAFE PLACE

2.  When “TEST” starts flashing again, locate the most distant smoke alarm you want detected. 

 

3. Press and hold the test button on the smoke alarm until the Lifetone HL™

    alarm sounds.    Between 7 and 9 smoke alarm T3 cycles (groups of 3 beeps)

    will be required. This takes about 30 to 40 seconds.

4.  When the Lifetone HL™ alarm sounds and  “ F I R E ” appears on the screen,

    the test has been successful. 

5.  To stop the alarm, press the red TEST/SILENCE button on the back of the clock. 

6. If all tests are passed, the “12 hr” time display option will flash on the

    screen, and you may now set the clock.  Go to STEP 3. 

NOTE:   If the clock is flashing all segments as shown below and beeping at 

short intervals, your smoke alarm was not detected or is not compatible with

the LIFETONE  HL™.  

Unplug the clock and remove one battery.  Repeat the set up beginning with 

STEP 1- POWERING THE PRODUCT.   You may need to choose a closer smoke alarm.

If the compatibility test fails again, the smoke alarm may not be compatible. Unplug 

the clock and remove the batteries. See the section titled “UNSUCCESSFUL SMOKE 

ALARM COMPATIBILITY TEST” in the user’s manual.     

1. The word “TEST” is flashing on the screen. Press the red TEST/SILENCE button on 

     the back of the clock.  The word “TEST” will stop flashing for 30 to 50 seconds.