© 2013 LifeSource Water Systems, Inc.
5
PowerTAC Physical Properties
Template Assisted Crystalization Composition - Specially treated polymer
Operating Conditions
Can be used in continuous or intermittent operation. Install on cold water
supply only. No backwash required.
Water Chemistry Specifications
pH
6.5 to 8.5
Max. Hardness
75 grains (1300 ppm CaCO3)
Temperature
40 to 110
˚ F
Max. Chlorine
<3 ppm
Max. Iron, ferrous
0.3 mg/I
Max. Manganese
0.05 mg/I
Max. Copper
1.3 mg/I
Oil & H2S
Remove pre ScaleSolver™
Polyphosphates
Remove pre ScaleSolver™
Specifications
Max Dimensions
79” x 17”
Max. Flow Rate
75 gpm
Max. Temperature
100
˚F (37.8˚ C)
Max. Pressure
90 psi
Inlet Connection
2” PVC Union with Socket
Outlet Connection
2” PVC Socket
Service Weight (Wet)
420lbs.
TM
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
EQUIPMENT SPECIFICATIONS
The ScaleSolver™ SS-7722LE is complete, self-contained, loaded with media and ready to use. A simple inlet and
outlet connection is all that is required for installation. Please review operating pressures, temperatures and water
chemistry limitations to ensure compatibility.
Using ScaleSolver with other water treatment equipment
Due to the unique properties of ScaleSovler™, there are some unique
requirements for using ScaleSolver™ in conjunction with filtration or other
forms of water treatment.
1. ScaleSolver™ must be the last stage in the treatment chain. Do not install
any filters after ScaleSolver™ or before any devices for which scale preven-
tion is required. POU filters, e.g. carbon or R.O. are exempt from this require-
ment.
2. Do not apply phosphate or any other antiscalant either before or after
ScaleSolver™.
TM
Template Assisted Crystallization is a registered
trademark of Next Filtration Technologies, Inc.
Installation, Operation and Maintenance Manual
ScaleSolver SS-7722
TM