![lifeSMART LS-330 User Manual Download Page 2](http://html1.mh-extra.com/html/lifesmart/ls-330/ls-330_user-manual_1910072002.webp)
◆
In the anus (rectal)
This is the most reliable measuring method, and is especially suitable
for infants and small children. Carefully insert the measuring probe
(
③
) of the thermometer 2 to 3cm into the anal aperture.
Note: To take the rectal temperature of a new born, baby, lay the baby
on its back on a hard surface and lift its legs to an angle of approximately 90°. Hold them
by the ankles in order to prevent their body from turning while taking the temperature.
Remember that the internal body temperature is always slightly higher than the external
temperature (about 0.5°C).
When the measuring is completed, read the measurement value by LCD.
It a
ctivate
s
the
backlight according to the temperature range.
- If the value is between 37.6°C-43.9°C, it has “BI BI……”sound three times,and the red
LED light on 5 second.
- If the value is between 32°C-37.5°C, it has “BI BI……”sound three times,at 36.2°C-37.5°C
(97.2°F-99.5°F) range, the green LED light on 5 second.
After taking the temperature,
press
the “Standby/ Scan button” (
②
) (if you forget to
thermometer off, it is switched off automatically after about 3±0.5 minutes).
After the measurement, put the thermometer into the protective cover.
Cleaning and disinfecting
Use an medical alcohol (
≧
75%) swab or cotton tissue moistened with alcohol (70%
Isopropyl) to clean the measuring probe of thermometer.
In order to guarantee your health, please disinfect the measuring probe according
to above procedures before and after the measur
ement
.
If the unit body is smudged, use a soft, dry cloth to clean the thermometer display and
exterior.
NOTES:
●
Don not use abrasive cleaners.
●
Don’t use other non-recommended methods to perform disinfect
ion
.
Storage
●
Don’t leave the thermometer exposed to
high risk
,
direct sunshine, high temperature,
dampness, fi
r
e, flame, vibration or impact.
●
Remove the battery for long time of no use.
Calibration
●
The thermometer is initially calibrated at the time of manufacture. We recommend
this thermometer is tested for accuracy every two years or after device impact (e.g. be-
ing dropped).
Accessories
Only use original accessories. Check that the contents of the delivery are complete.
Quantity
Parts
1pc
LS-330
device
1pc
Transparent protective cover
1pc
User Manual
Trouble-shooting
Troubles or error message
Checklists or situation
Countermeasures or
solution
No response/ Automatically
reset
Battery used up?
Replace new battery
Battery in wrong polarity or
type?
Take out battery, reinsert
it correcty
Poor battery contact
Temperature taken is not
w i t h i n t y p i c a l h u m a n
temperature range (32.0-
43.9°C or 89.6-111.0°F)
Hi= too high
--- = too low
Follow User’s Manual to re-
measurement;
Make sure a new, clean
probe cover is attached and
thermometer is properly
inserted. Then, take a new
temperature.
Technical Specifi ations
Model
LS-330
Measurement mode
Highest temperature hold
Measurement type
Predictive thermometer
Measurement range
32.0-43.9°C(89.6-111.0°F)
Measurement accuracy
±0.1°C(or±0.2°F): from 35.5-42.0°C(95.9-107.6°F)
±0.2°C(or±0.4°F): form other ranges
Digital increment of displayed tem-
perature
0.1°C/ 0.1°F
Operation environment:
10-35°C (50-95°F); 20-85% RH
Storage environment:
-25-55°C (-13-131°F); 20-85% RH
Power supply
d.c. 3V, one CR1632 battery
Measurement time
8-12s (for human body)
Measurement memory
Last time memory display
High body temperature hint
≥37.6°C
(99.7°F)
Grade of waterproof
IP22
Electric shock
Internally powered ME equipment
Applied part
Type BF applied part
Mode of operation
Continuous operation
Note: Not intended to be sterilized.
Not for use in an OXYGEN RICH ENVIRONMENT
Standard list
Famidoc Technology Co., Ltd declares that the FDTH-V0-4 complies with following appli-
cable standards:
EN ISO 15223-1 Medical device – Symbols to be used with medical device labels, label-
ing and information to be supplied – Part 1: General requirements
EN 1041
Information supplied by the manufacturer with medical devices
EN 60601-1
Medical electrical equipment Part 1: General requirements for basic
safety and essential performance
EN 60601-1-2
Medical electrical equipment -- Part 1-2: General requirements
for basic safety and essential performance - Collateral standard:
Electromagnetic compatibility - Requirements and tests
EN 12470-3
Clinical thermometers- Part 3: Performance of compact electrical
thermometers (non-predictive and predictive) with maximum device
EN 62304
Medical device software - Software life-cycle processes
EN ISO 10993-1 Biological evaluation of medical devices - Part 1: Evaluation and testing
within a risk management process
IEC 60601-1-11
Medical electrical equipment – Part 1-11: General requirements
for basic safety and essential performance – Collateral Standard:
Requirements for medical electrical equipment and medical electrical
systems used in the home healthcare environment
Disposal
Dispose of the device in accordance with the regulations applicable at the
place of operation.
Dispose of at public collection point in the EU countries – 2002/96/EC WEEE
Directive.
If you have any queries, please refer to the local authorities responsible for
waste disposal.
NOTES:
• Hand
l
ing of battery and wastes method, please act according to the native law
to
proceed to handle.
• Take out the battery if you are not going to use the unit for a long time.
To protect the environment, dispose of empty battery at your retail store or at
appropriate collection sites according to national or local regulations.
NORMALIZED SYMBOLS
Follow operating instructions
BF type applied part
Disposal in accordance with Directive 2002/96/EC (WEEE)
Complies with the European Medical Device Directive (93/42/EEC
and amended Directive 2007/47/EC.Notified Body is SGS United
Kingdom Ltd.
Manufacturer information: The manufacturer is: Famidoc Technology
Co., Ltd.
Batch code
Date of manufacture
WARRANTY
One
year warranty
+ One year extended warranty
Your digital thermometer is durable and manufactured for normal household
use. Following directions carefully will ensure years of dependable operation. If for any
reason (other than misuse and normal battery replacement) you are
dissatisfied with your thermometer,
w
e will repair or replace it, at our option, free
during the warranty period. Modification to the product by the consumer is not
authori
s
ed and voids the warranty.
Shanghai International Holding Corp. GmbH(Europe)
Add: Eiffestrasse 80, 20537 Hamburg Germany
Tel: +49-40-2513175 Fax: +49-40-255726
Copyright 201
5
Edition: V1.0
Manufactured For: GENESIS BIOTECH PTY LTD
Address: Level 1, 16 McDougall Street, MILTON QLD 4064 Australia
www.mylifesmart.net.au
For Australia & New Zealand customers [email protected]
Australian customers 1300 110 155
Famidoc Technology Co., Ltd.
Add. : No. 212 Yilong Road, Hexi Industrial Zone, Jinxia,
Changan Town, Dongguan, Guangdong Province, P.R. China. PC: 523853
Tel: +86-769-89272488
Fax: +86-769-89272498
Website: www.famidoc.com