lifeSMART LS-330 User Manual Download Page 2

In the anus (rectal)

This is the most reliable measuring method, and is especially suitable 

for infants and small children. Carefully insert the measuring probe
(

 

 

) of the thermometer 2 to 3cm into the anal aperture.

Note: To take the rectal temperature of a new born, baby, lay the baby 

on its back on a hard surface and lift its legs to an angle of approximately 90°. Hold them 

by the ankles in order to prevent their body from turning while taking the temperature.

Remember that the internal body temperature is always slightly higher than the external 

temperature (about 0.5°C).

When the measuring is completed, read the measurement value by LCD. 

It a

ctivate

s

the

 

backlight according to the temperature range. 

-  If the value is between 37.6°C-43.9°C, it has “BI BI……”sound three times,and the red 

LED light on 5 second. 

-  If the value is between 32°C-37.5°C, it has “BI BI……”sound three times,at  36.2°C-37.5°C 

(97.2°F-99.5°F) range, the green LED light on 5 second. 

After taking the temperature, 

press

 the “Standby/ Scan button” (

 

 

) (if you forget to 

thermometer off, it is switched off automatically after about 3±0.5 minutes).

After the measurement, put the thermometer into the protective cover. 

Cleaning and disinfecting

Use an medical alcohol (

 

 

75%) swab or cotton tissue moistened with alcohol (70% 

Isopropyl) to clean the measuring probe of thermometer.

In order to guarantee your health, please disinfect the measuring probe according 

to above procedures before and after the measur

ement

.

If the unit body is smudged, use a soft, dry cloth to clean the thermometer display and 

exterior.

NOTES:

Don not use abrasive cleaners.

Don’t use other non-recommended methods to perform disinfect

ion

Storage

Don’t leave the thermometer exposed to

 

high risk

direct sunshine, high temperature, 

dampness, fi

r

e, flame, vibration or impact.

Remove the battery for long time of no use. 

Calibration

 The thermometer is initially calibrated at the time of manufacture. We recommend

 

this thermometer is tested for accuracy every two years or after device impact (e.g. be-

ing dropped).

Accessories

Only use original accessories. Check that the contents of the delivery are complete.

Quantity

Parts

1pc

LS-330

 device

1pc

Transparent protective cover

1pc

User Manual

Trouble-shooting

Troubles or error message

Checklists or situation

Countermeasures or 

solution

No response/ Automatically 

reset

Battery used up?

Replace new battery

Battery in wrong polarity or 

type?

Take out battery, reinsert 

it correcty

Poor battery contact

Temperature taken is not 

w i t h i n   t y p i c a l   h u m a n 

temperature range (32.0-

43.9°C or 89.6-111.0°F)

Hi= too high

--- = too low

Follow User’s Manual to re-

measurement;

Make sure a new, clean 

probe cover is attached and 

thermometer is properly 

inserted. Then, take a new 

temperature.

Technical Specifi ations

Model

LS-330

Measurement mode

Highest temperature hold

Measurement type  

Predictive thermometer

Measurement range

32.0-43.9°C(89.6-111.0°F)

Measurement accuracy

±0.1°C(or±0.2°F): from 35.5-42.0°C(95.9-107.6°F) 

±0.2°C(or±0.4°F): form other ranges

Digital increment of displayed tem-

perature

0.1°C/ 0.1°F

Operation environment:

10-35°C (50-95°F); 20-85% RH

Storage environment:

-25-55°C (-13-131°F); 20-85% RH

Power supply

d.c. 3V, one CR1632 battery

Measurement time

8-12s (for human body)

Measurement memory

Last time memory display

High body temperature hint

≥37.6°C

(99.7°F)

Grade of waterproof

IP22

Electric shock

Internally powered ME equipment

Applied part

Type BF applied part

Mode of operation

Continuous operation

Note: Not intended to be sterilized.

Not for use in an OXYGEN RICH ENVIRONMENT

Standard list

Famidoc Technology Co., Ltd declares that the FDTH-V0-4 complies with following appli-
cable standards:

EN ISO 15223-1 Medical device – Symbols to be used with medical device labels, label-

ing and information to be supplied – Part 1: General requirements

EN 1041

Information supplied by the manufacturer with medical devices

EN 60601-1

Medical electrical equipment Part 1: General requirements for basic 

safety and essential performance

EN 60601-1-2

Medical electrical equipment -- Part 1-2: General requirements 

for basic safety and essential performance - Collateral standard: 

Electromagnetic compatibility - Requirements and tests

EN 12470-3

Clinical thermometers- Part 3: Performance of compact electrical 

thermometers (non-predictive and predictive) with maximum device

EN 62304

Medical device software - Software life-cycle processes

EN ISO 10993-1 Biological evaluation of medical devices - Part 1: Evaluation and testing 

within a risk management process

IEC 60601-1-11

Medical electrical equipment – Part 1-11: General requirements 

for basic safety and essential performance – Collateral Standard: 

Requirements for medical electrical equipment and medical electrical 

systems used in the home healthcare environment

Disposal

Dispose of the device in accordance with the regulations applicable at the 

place of operation.

Dispose of at public collection point in the EU countries – 2002/96/EC WEEE 

Directive.

If you have any queries, please refer to the local authorities responsible for 

waste disposal.

NOTES:

• Hand

l

ing of battery and wastes method, please act according to the native law

to

 

proceed to handle.

• Take out the battery if you are not going to use the unit for a long time. 

To protect the environment, dispose of empty battery at your retail store or at 

appropriate collection sites according to national or local regulations.

NORMALIZED SYMBOLS

Follow operating instructions

BF type applied part

Disposal in accordance with Directive 2002/96/EC (WEEE)

Complies with the European Medical Device Directive (93/42/EEC 

and amended Directive 2007/47/EC.Notified Body is SGS United 

Kingdom Ltd.
Manufacturer information: The manufacturer is: Famidoc Technology 

Co., Ltd. 
Batch code

Date of manufacture

WARRANTY

One

 year warranty

 + One year extended warranty

Your digital thermometer is durable and manufactured for normal household 

use. Following directions carefully will ensure years of dependable operation. If for any 

reason (other than misuse and normal battery replacement) you are 

dissatisfied with your thermometer, 

w

e will repair or replace it, at our option, free 

during the warranty period. Modification to the product by the consumer is not 

authori

s

ed and voids the warranty.

Shanghai International Holding Corp. GmbH(Europe)

Add: Eiffestrasse 80, 20537  Hamburg Germany

Tel: +49-40-2513175          Fax:    +49-40-255726

Copyright 201

5  

Edition: V1.0

Manufactured For: GENESIS BIOTECH PTY LTD 

Address: Level 1, 16 McDougall Street, MILTON QLD 4064 Australia

www.mylifesmart.net.au

For Australia & New Zealand customers [email protected] 

Australian customers 1300 110 155

Famidoc Technology Co., Ltd.

Add. : No. 212 Yilong Road, Hexi Industrial Zone, Jinxia, 

Changan Town, Dongguan, Guangdong Province, P.R. China. PC: 523853

Tel: +86-769-89272488

Fax: +86-769-89272498

Website: www.famidoc.com

Reviews: