background image

 LifeSize Bridge 2200 Administrator Guide

28

Upgrading your System Software

Before you upgrade your system software, ensure that the system meets the following prerequisites:

A current license key for upgrading exists on the system. The expiration date for the upgrade license 
appears in 

Maintenance : License Keys

. Read more at 

Updating License Keys

.

NOTE

An upgrade fails if a current license key does not exist on the system. If a 
current license key does not exist, contact your authorized LifeSize Partner to 
renew your maintenance agreement. The renewal process may require 24 to 
48 hours to complete.

Terminate all calls prior to upgrading. Create a maintenance window by scheduling a conference that 
uses all ports and has a password that is not shared. 

To upgrade the software for your system, follow these steps:

1.

Click the 

Download Software 

button on 

lifesize.com/support

.

2.

Enter your serial number (located on the bottom or back of your system and in 

Diagnostics : System 

Information

).

3.

Click the link for the software version you wish to download.

4.

Download it to a local directory on your system.

5.

Access the LifeSize Bridge Utility.

6.

Click 

Maintenance : System Upgrade

.

7.

Browse for the upgrade file you downloaded in step 4.

The system automatically validates the file. If you want to re-validate the same file, or if you manually 
enter a path to a file, you must click 

Validate

 for the verification to occur.

If calls are connected to the system, a message prompts you to terminate all calls and create a 
maintenance window prior to upgrading. To create a maintenance window, create a conference 
(approximately 30 minutes) that uses all ports and has a password that is not shared.

8.

If the validation succeeds and your upgrade requires you to reset the system to the original default 
settings, select 

Reset to Default State

.

9.

Click 

Upgrade Now.

The upgrade may take several minutes; do not disrupt the upgrade process. During an upgrade, a 
status screen appears. Keep the utility window open to monitor the upgrade process. If you close the 
window before the file upload completes, the upload is cancelled. If you close the window after the file 
upload completes, the upgrade process continues, but you are no longer able to monitor the upgrade 
process.

A system upgrade status message appears when the upgrade is complete and the system 
automatically reboots. 

If the software you are attempting to install is an older version than what is currently installed, the 
button appears as 

Downgrade Now

.

Summary of Contents for Bridge 2200

Page 1: ...LifeSize Bridge 2200 Administrator Guide June 2011...

Page 2: ......

Page 3: ...individual participant joining a conference conference a conference with multiple participants hosted by the bridge expanded conference a conference hosting up to 48 participants a license key is requ...

Page 4: ...of connected video calls Number of connected voice calls Available The number of remaining ports not active or not scheduled A shortcut to Diagnostics System Health providing a quick view of your sys...

Page 5: ...ommodate up to 48 participants NOTE Expand is available for scheduled conferences only if all ports are available and if a license for this feature is available Read more about Expanding Your Conferen...

Page 6: ...s must enter to join the conference Select Display Password to include the password in the meeting invitation Passwords must contain digits only 6 Select All Day or adjust the time frame for the start...

Page 7: ...ence Auto Security Encryption level used for the conference Auto allows both encrypted and unencrypted calls Off provides no encryption Strict connects encrypted calls only Auto Resolution The video r...

Page 8: ...erence license key Sharing Presentations Users can share data during a call through a secondary H 239 media channel typically from a laptop or personal computer that is connected to the appropriate in...

Page 9: ...an increase or decrease the value in the Refresh Interval box and click Refresh to update the number of seconds to refresh the values Identifies the participant as a voice call Identifies the particip...

Page 10: ...tatus with the communication protocol The following values may appear Modifying Conferences You can configure most conference attributes including conference name and description password ports start...

Page 11: ...conference name you wish to modify or delete and double click right click or click NOTE A limited set of edit options are available for active conferences to ensure uninterrupted connectivity Add part...

Page 12: ...cipants join the conference after all available spaces in the current layout are filled the layout changes to the next best fit layout The layout also changes to the best fit as participants exit the...

Page 13: ...Administrator Guide 13 If four maximum participants are allocated for the conference the following layouts are available If 5 to 7 maximum participants are allocated for the conference the following l...

Page 14: ...nected the setting for Self View is ignored until a second caller joins the conference Self View is disabled by default Changing Layouts for an Individual Call 1 From the Call Manager select the call...

Page 15: ...desired layout 4 Click Disable Speaker Order which disables speaker order for everyone in the conference 5 Select Promote Participant 6 Choose the participant you wish to move into the prominent windo...

Page 16: ...Network is set to Enabled and the DHCP server can pass an NTP server address to your system You specify the hostname or IP address of an NTP server in NTP Server Hostname NOTE The value you specify fo...

Page 17: ...Network Port Redundancy Select the checkbox to enable redundancy specify the ports you are using and specify the type of port redundancy The port status current IP address and subnet mask for all ena...

Page 18: ...ng ports TCP port 1720 for H 323 call setup UDP port 5060 for SIP call setup TCP port 5060 for SIP call setup if TCP signaling is enabled for SIP calls TCP port 5061 for TLS signaling in SIP calls if...

Page 19: ...xtension for the system enter that number for H 323 Extension Set the Gatekeeper ID only if the gatekeeper requires it for example configurations with multiple gatekeepers The Gatekeeper ID must match...

Page 20: ...oots if you change the UDP signaling port enable or disable TCP or TLS signaling or change the TCP or TLS signaling ports If you enable TLS signaling the system attempts to use Secure Real time Transp...

Page 21: ...mand Refer to the LifeSize Bridge Installation Guide for more information about running commands from the console Enabling FIPS 140 2 Security LifeSize Bridge 2200 supports the Federal Information Pro...

Page 22: ...eachable Unreachable destination The call could not connect to the other party Destination rejection The call was rejected and could not connect Call deflection The call request was redirected In conf...

Page 23: ...s System Information displays details about your system including serial numbers and versions You can export this data to a text HTML or XML file by clicking the corresponding button for the format yo...

Page 24: ...TLS signaling ports Upgrade the system software Maintenance System Upgrade Change IP address Change protocol and network preferences these are disabled if calls are in progress Schedule a maintenance...

Page 25: ...a current saved configuration file exists before performing a restore NOTE Configuration preferences and options vary across software releases Restoring a system configuration using a file saved from...

Page 26: ...system A current license key for upgrades is available when a maintenance agreement for the system is in effect The license key table in Maintenance License Keys lists the expiration date of the licen...

Page 27: ...or this system No licenses found for this system License key server busy Try again Ensure a current maintenance agreement for the system is in effect and ensure you have entered the key correctly Inst...

Page 28: ...k Maintenance System Upgrade 7 Browse for the upgrade file you downloaded in step 4 The system automatically validates the file If you want to re validate the same file or if you manually enter a path...

Page 29: ...own error The upgrade failed for undetermined reasons Upgrade in progress An upgrade is already in progress The system only supports one upgrade at a time Bad upgrade file format The upgrade image is...

Page 30: ...part of the document may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission from LifeSize Communications Trademar...

Reviews: