background image

LIFESAVER  

WAYFARER

  

USER  

MANUAL

Summary of Contents for WAYFARER

Page 1: ...LIFESAVER WAYFARER USER MANUAL...

Page 2: ...the Ultrafiltration Cartridge 8 Changing the Activated Carbon Filter 9 Basic Filter Cleaning 10 Storage and Deep Cleaning 11 How to Check your Filter is Working Correctly 12 Membrane Integrity Check 1...

Page 3: ...ndle Replaceable Activated Carbon Disc Replaceable Ultrafiltration UF Cartridge Scavenger In Hose spigot Scavenger In Hose Out Hose spigot Out Hose Pre filter A B C D E G H F YOUR LIFESAVER WAYFARER 7...

Page 4: ...cone dust cap this must be removed before first use 2 When not in place on the outlet spigot this should be stored on the underside of the handle We recommend refitting the dust cap for long term stor...

Page 5: ...4 times Wait 2 minutes 5 Ensuring the pre filter is still fully submerged pump slowly Water should begin flowing through the Out Hose Use the PRV as per page 7 to aid initial flow Continue until appr...

Page 6: ...down for an instant flow of purified water 5 Ensure your scavenger hose is always submerged If you pump air into the unit the flow rate will slow and the pump will become difficult to use Operate the...

Page 7: ...alve PRV PRESSURE RELIEF VALVE PRV 1 After pumping your Wayfarer turn it upside down and press the Relief Valve down 2 If air was trapped you will hear it hiss As soon as water releases let go of the...

Page 8: ...ayfarer firmly with one hand and using your other hand rotate the tool and filter anti clockwise around 30 degrees until you feel it stop 5 Finally pull the removal tool straight up separating the UF...

Page 9: ...re seal around the carbon and re use for your new Activated Carbon Filter 4 Turn the Wayfarer back over so the open end of the filter chamber is facing up and drop in a new Activated Carbon Filter wit...

Page 10: ...e filter the white straws beneath the blue grill with clean water to remove dirt and debris Keep doing so until the water runs clear Be careful not to damage the filter by using excessive water pressu...

Page 11: ...c Filter Cleaning instructions on page 10 3 Clean the pre filter basket by simply removing from the hose and washing under a tap until clean Reassemble once cleaned 4 Re fit the UF Cartridge 5 Fill a...

Page 12: ...Wayfarer has been subjected to shock or when you suspect damage may have occurred MEMBRANE INTEGRITY CHECK 1 Remove the Out Hose and use your Wayfarer as normal During the pumping cycle remove the Sca...

Page 13: ...n the condition it was purchased the shelf life of the product will be up to 10 years from the date of manufacture Activated Carbon Filters An Activated Carbon Filter if sealed in its original foil wr...

Page 14: ...cleaning the UF Cartridge if this doesn t improve the flow rate it s time to replace the UF Cartridge PERFORMANCE AND TECHNICAL DATA Minimum operating storage temperature 0 C 32 F Maximum operating st...

Page 15: ...tended to provide a guideline for the selection and use of our products Since the conditions under which our product may be used are beyond our control this information does not imply any guarantee of...

Page 16: ...www iconlifesaver com E info iconlifesaver com T 44 0 1206 580 999 ESSENTIAL CONTACT DETAILS 2022 Icon LifeSaver Ltd All rights reserved...