LifeSafety Power PROWIRE RGA150B-D8Z/T8-A Manual Download Page 2

July 2022

2/2

www.lifesafetypower.com

 LSP 

PROWIRE  |  

AMAG 8DR RACKMOUNT

System Specifications

Power Supplies

FPO150

Power supply board, 4A/24V

B100

Secondard voltage module, 4A/12V class 2 power limited
Input 120/230VAC 50/60Hz | 83 Watts (0.69A)

Overload and short circuit protection

Over temperature protection

Polarized AC power supply disconnect

Battery Charging

Independent built-in charger for sealed lead-acid or gel type batteries

Microprocessor dual rate charging of 12 or 24V battery sets

Automatic switchover to standby battery when AC fails

Zero voltage drop when switched over to battery backup

Supervision

AC Fault (form "C" contacts)

System Fault (form "C" contacts) 

System Fault conditions: Low or no battery | short to earth ground | power supply failure

Distribution Modules

D8

8 auxiliary outputs, fused at 3A per output

F8

8 egress outputs, fused at 3A per output

Network Management

NL2

Two port module. Monitors and reports power supply status. Tests and reports battery health status.

Enclosures

RGA

2U rack mount (19.00"W x 3.50"H x 20.50"D) | Weight 24 lbs. | Z bracket wire management articulating arm

Wiring Suffix

T8-A 

T

 = 

Tie Wrap

  

 

8

 = 

Door count   

A

 = 

M2150

T8-C

T

 = 

Tie Wrap

  

 

8

 = 

Door count   

C

 = 

M4000

Regulatory Compliance

UL / ULC

UL294, ULC S319

CSA / FCC

CSA C22.2 #107.1  |  FCC Part 15, CSFM

System Examples

4DC (X2)

8DBC

B

8DBC

A

M4000

C

LifeSafety Power

10027 S. 51st Street, Suite 102

Phoenix, AZ 85044 USA

PH 888-577-2898

[email protected] 

P01-1024A     07/22

LifeSafety Power warrants to the original purchaser only that all products will be free from defects in material or workmanship at time of shipment. This warranty is 

non-transferable.  Our obligation under this warranty is limited to repair or replacement, at the sole discretion of LifeSafety Power, of products that are defective in 

material or workmanship at the time of shipment provided they were used within the specified ratings and installed in accordance with accepted engineering practices. 

Products in the Unified Wired Systems Classification will be wired to the LifeSafety Power description of operation unless otherwise stated. At the time of installation it 

is the obligation of the purchaser or final installer to verify that all wired terminations provide the desired operation. In no event shall LifeSafety Power be responsible for 

any special, incidental or consequential damages even if LifeSafety Power has been advised of the possibility of such damages. Customer hereby agrees to indemnify 

LifeSafety Power for and hold LifeSafety Power harmless from and against any and all loss, cost or expense (including reasonable attorneys’ fees) directly or indirectly 

related to any claim with respect to Unified Wired™ systems classification products except to the extent any such claim shall result from the gross negligence or willful 

misconduct of LifeSafety Power.