Key Features
• The Dehumidistat measures the indoor humidity level and will
initiate high speed ventilation when the moisture level in the
building exceeds the set point on the control.
• Once the humidity in the building is reduced, the unit will revert to
its previous setting.
• The Dehumidistat should be set to OFF for all season except the
heating season.
• Connect to 3 wire 20 gauge low voltage wire.
Humidity Control
Your HRV will produce a dehumidifying effect when outdoor humidity
levels are lower than indoor humidity levels. Never use the
dehumidistat feature when outdoor temperatures are above 59 F (15 C).
Note: The indoor humidity level is measured at the control.
Setting the Dehumidistat
Press and release the DEHUMIDISTAT button until the
DEHUMIDISTAT LIGHT is at the desired setting. After 5 seconds the
dehumidistat light will either flash or be on continuous.
A flashing light indicates the humidity level is higher than the setting
and the unit is operating on high speed ventilation. A continuous light
indicates the humidity level is lower than the setting. Connect to 3 wire
20 gauge low voltage wire. Mounts in a standard 2” x 4” electrical box.
Note - Only 1 dehumidistat should be active on a system.
Optional Dehumidistat - Part #99-DH-01
%
80
20
Instruction card
Dehumidistat Indicator
LEDs
Set to the desired humidity
level. High speed ventilation
will initiate when the indoor
moisture level exceeds the set
point on the control.
Dehumidistat
Adjust button
Lifestyle 20/40/60 Minute Timer
Part # 99-DET01
Initiates high speed ventilation for 20, 40 or 60 minutes. The 20/40/60
Minute Status Lights indicate high speed operation.
Lockout Mode is useful if you wish to disable the timer. Set lockout by
holding the Select Button for 5 seconds. Unlock by holding for
5 seconds.
Connect to 3 wire 20 gauge low voltage wire. Mounts in a standard
2" x 4" electrical box.
Lifestyle 20 Minute Timer
Part # 99-20M01
Initiates high speed ventilation for 20 minutes. The 20 Minute Status
Light indicates high speed operation.
Lockout Mode is useful if you wish to disable the timer. Set lockout by
holding the select button for 5 seconds. Unlock by holding for
5 seconds.
Connect to 3 wire 20 gauge low voltage wire. Mounts in a standard
2" x 4" electrical box.
Optional Timers
Select Button
Select Button
20/40/60 Minute
Status Lights
20 Minute
Status Lights
The timer will override the Operational Mode (regardless of the
settings) and initiate high speed ventilation. Upon completion of the
timer cycle, the HRV will return to your selected Operational Mode
and speed setting.