Options
99-186
Weatherhoods, Two - 6" c/w
1/4" mesh screen
99-130W
Remote Wall Mount Dehumidistat
Control 24 VAC only
99-RSK6
6” back draft damper
Top
Side
Front
29.5"
29.5"
19"
47.5"
6"
6"
®
C L E A N A I R F U R N A C E
14"
12"
4"
19"
22.25"
Duct (coil)
Opening
17.25"
Ventilation
Supply Air
Inlet
Ventilation
Exhaust Air
Outlet
22"
Return
Plenum
Latches
Blower Section
(SERVICE CLEARANCE 1')
(SERVICE CLEARANCE 3')
Specifications
Model 60VENTAC
(No Heating Coil)
Core
Ventilation system has patented aluminum heat recovery core (standard) or an enthalpic energy
recovery core (optional) for energy-efficient ventilation. Enthalpic cores are recommended for
regions where the temperature does not drop below 25˚F (-4˚C).
Filters
Washable air filters in exhaust and supply air streams of ventilation section, 1" pleated in
return plenum side.
Case
Prepainted galvanized steel for superior corrosion resistance.
Dimensions & Clearances
Note: Ventilation ports and
return plenum opening
available off either side of
cabinet. All units conform
to CSA and UL Standards.
20
Model
60VENTAC
Voltage
120 VAC 60 Hz
Hp
1/2
Amps (total)
7.7
*
Airflow (High)
.25 in wg
1350 CFM
.5 in. wg
1180 CFM
Ventilation
100 - 140 CFM
Airflow
Effectiveness
70%
(Aluminum Core)
Total Efficiency
50%
(Enthalpic Core)
Net Weight
115 lbs.
Shipping Weight
130 lbs.
* Airflow performance assumes an evaporator
coil static pressure loss of .25” WC
Warranty
Units carry a lifetime warranty on the heat
recovery (aluminum) core, a five year warranty
on the energy recovery (enthalpic) core and a
five year replacement parts warranty on all
other components.