Model 200 ERVD
®
C L E A N • F R E S H • A I R
ENGINEERING DATA
LATENT RECOVERY/MOISTURE TRANSFER CORE
The cross-flow energy recovery core transfers heat and water vapour
between the two airstreams. It is easily removed for cleaning or service.
MOTORS AND BLOWERS
- Each air streams has one centrifugal blower
driven by a common PCS motor. 5 speed fan operation.
High speed - 120 VAC, 1.4 Amps, 164 Watts.
FILTERS
- Washable air filters in exhaust and supply air streams.
MOUNTING THE ERV
- Four 10/24" (10.5 mm) threaded inserts at
corners of case designed to accept four PVC reinforced polyester straps
that are supplied with the unit.
DEFROST
- Damper defrost system.
CASE
- Twenty gauge prepainted galvanized steel (G60) for superior
corrosion resistance. Insulated to prevent exterior condensation.
DRAIN CONNECTIONS
- Two - 1/2” (12mm) O.D.
CONTROLS
- ControlAir 15
WEIGHT 63 lbs. (28.7 kg) SHIPPING WEIGHT 65 lbs. (29.6 kg )
PERFORMANCE
HVI CERTIFIED
Net supply airflow in cfm (L/s) against external static pressure
E.S.P
cfm
L/s
@ 0.1” (25 Pa)
195
(92)
@ 0.2” (50 Pa)
185
(87)
@ 0.3” (75 Pa)
175
(83)
@ 0.4” (100 Pa)
160
(76)
@ 0.5” (125 Pa)
145
(68)
Sensible Effectiveness
@ 110 L/s (55 cfm)
(CSA C439M)
80%
Sensible Efficiency
@ 110L/s (55 cfm) @0
O
C (32°F)
70%
Sensible Efficiency
@ 110 L/s (55 cfm) @ -25
O
C (-13°F)
55%
VAC @ 60HZ
120
WATTS / Low speed
80
Amp rating
1.4
STALE AIR
TO OUTSIDE
STALE AIR
FROM HOUSE
FRESH AIR
TO INSIDE
14
3
/
4
"
(375)
19"
(483)
DIMENSIONS 200 ERVD
inches (mm)
*
All Duct Connections 6"(150mm)
FILTERS
BLOWERS
*NOTE: Front clearance
of 25 inches (635 mm)
is recommended
for servicing unit.
MOTOR
31"
(787)
FRESH AIR
FROM OUTSIDE
DAMPER
DEFROST
PORT
CONDENSATE DRAINS
OPTIONS
99-104 Digital Electronic Timer - 20/40/60 min. (3 wire)
99-105 Deluxe Programmable Control includes
Programmable Time Clock, Dehumidistat
and Air Sentry™
99-109 Air Sentry™ Air Quality Monitor
99-186 Weatherhoods, Two - 6” (150mm)
c/w 1/4” (6mm) mesh screen
WARRANTY
Units carry a 5 year warranty on the energy recovery core and
replacement parts.
All units are CSA and UL standards.
It is not recommended for regions where the temperature
does not drop below 25°F (-4°C)