background image

About the Simulator 

The 

Life

/

form

®

 Child Defibrillation 

Chest Skin has been designed to be 

placed on the Resusci

®

 Junior* brand 

of CPR manikin to enable you, the 

customer, to safely practice defibrilla-

tion. 

(See figure 1.)

Figure 1

The Child Defibrillation Chest Skin has 

been designed to absorb a maximum 

of 360 joules of energy**. Although 

capable of absorbing 360 joules, 

we do recommend that the smallest 

energy level possible be used while 

training with the skin.

The Child Defibrillation Chest Skin 

will enable you to practice defibrilla-

tion using manual, semiautomatic, 

and automatic external defibrillators 

(AEDs). When using any one of these 

types of defibrillators in training, always 

follow the recommended operating 

procedures for that particular defibril-

lator. Our chest skin has been spe-

cially designed to accommodate the 

Resusci

®

 Junior* CPR manikin.

List of Components

(See figure 2.)

  •  Defibrillation Chest Skin with 

    Load Box and Four Lead Snap  

    Cable Connector
  •  Bottle of Nasco Cleaner
  •  Load Box Mounting Plate
  •  2 Machine Screws

Figure 2

Things You Will Need 

Phillips Screwdriver

**Note:

 

360 joules is the maximum 

energy level that Nasco recommends 

administering to the defibrillation 

chest skin. Energy levels in excess 

of 360 joules may cause irreparable 

damage to the chest skin, circuitry, 

and patient simulator being used – 

thus voiding Nasco’s warranty and 

endangering your equipment. Nasco 

assumes no liability for damage or 

injury that may be caused by the use 

and/or misuse of this equipment. All 

normal safety precautions for defibril-

lation training should be followed and 

energy levels should be minimized. 

Nasco did not design nor intend this 

defibrillation chest skin to be used as 

anything other than a training appara-

tus for defibrillation.

Set Up

The Child Defibrillation Chest Skin has 

been designed to replace the stan-

dard outer chest skin on the Resusci

®

 

Junior* CPR manikin, thus enabling 

you to safely defibrillate.
Please follow the set-up procedures 

for placing the Child Defibrillation Chest 

Skin on the manikin.

*RESUSCI

®

 JUNIOR IS A TRADEMARK OF LAERDAL MEDICAL CORPORATION.

1

NP016_96_LF03611   2

NP016_96_LF03611   2

10/5/12   10:24:12 AM

10/5/12   10:24:12 AM

Summary of Contents for LF03611U

Page 1: ...truction Manual Products by Nasco Q ment ment ement kin a Tutor ement fusion on a Stand ement anikin kin CPR Manikin Cricoid omplete nikin Manikin ltation ltation mulator kin Series eous hild Manikin n and 10 5 12 10 24 12 AM 10 5 12 10 24 12 AM ...

Page 2: ...ttle of Nasco Cleaner Load Box Mounting Plate 2 Machine Screws Figure 2 Things You Will Need Phillips Screwdriver Note 360 joules is the maximum energy level that Nasco recommends administering to the defibrillation chest skin Energy levels in excess of 360 joules may cause irreparable damage to the chest skin circuitry and patient simulator being used thus voiding Nasco s warranty and endangering...

Page 3: ...remove the four screws that hold the two halves of the upper body together These are located across the back of the shoulders See figure 4 Figure 5 7 Lift the top half of the body slightly away from the bottom releasing the tab that holds the neck in place See figure 5 8 Remove the head and neck from the body and remove the chest skin Figure 6 Installing the Load Box See figure 6 The next step is ...

Page 4: ... cable It can also be attached to an Arrhythmia Tutor which is available from Nasco through the Health Care Educational Materials Catalog For now simply uncoil the cable and allow it to hang freely from the manikin To reinstall the head simply reverse the procedure used to remove it Make sure to tighten the four body screws Figure 10 Next replace the chest compression plate that was removed earlie...

Page 5: ... tor doesn t have the standard snap connectors Please see accessories at the end of this manual Once your manikin is connected to your patient simulator you will be able to pick up the ECG waves either through the monitor hook ups on the skin or through the two disks attached to the skin on the defibrillation sites These disks will enable you to pick up the ECG wave using either the Quick Look pad...

Page 6: ... to you or your equipment Accessories LF03656U Physio Control Defribrillation Pad and Patient Simulator Adapter Package for LifePak 10 and Lifepak 20 LF03657U Marquette Electronics Defribrillation Pad and Patient Simulator Adapter Package LF03658U SpaceLabs Laerdal Heartstart First Medic Defibrillation Pad and Patient Simulator Adapter Package LF03961U Zoll Training Cables with Adapters LF03962U P...

Page 7: ...le Female Catheter LF01155U Advanced CPR Dog LF01162U Venatech IV Trainer LF01174U NG Tube Trach Skills LF01184U Venatech IM Sub Q LF01193U Special Needs Baby LF03000U CPARLENE Series LF03601U Adult Airway Management Trainer with Stand LF03602U Adult Airway Management Manikin LF03609U Child Airway Management Trainer with Stand LF03616U Child CRiSis Manikin LF03617U Deluxe Child CRiSis Manikin with...

Reviews: