background image

Electrical Power Requirements

The PowerMill with the Integrity and Discover consoles require an AC power supply according to the electrical
configurations listed in the chart below.

Console

Supply Voltage

Frequency

Output Voltage

Output Current

Integrity X/ C, Integrity
with Attachable TV,
Integrity SL, Discover / ST

100 - 240 VAC

50 - 60 Hz

24 VDC

5A

Outlet Voltage

Commercial Units Outlet & Breaker (Amps)

120 VAC

20 (no more than 1 PowerMill per breaker)

230 VAC

12 (no more than 1 PowerMill per breaker)

NOTE: Do not modify the plug provided with this product. If the plug does not fit into an available electrical outlet,
have a proper outlet installed by a qualified electrician.

Grounding Instructions

This product must be properly grounded. If the unit malfunctions or breaks down, proper grounding provides a path
of least resistance for the electric current, which reduces the risk of shock to anyone touching or using the equipment.
Each unit is equipped with an electrical cord, which includes an equipment grounding conductor and a grounding
plug. The plug must be inserted into an outlet that has been properly installed and grounded in accordance with all
local codes and ordinances.

NOTE: A temporary adapter MUST NOT BE USED to connect this plug to a two-pole receptacle in North America. If a
properly grounded, 15-amp outlet is not available, one must be installed by a qualified electrician. For use on a
nominal 120-V circuit, this product has a grounding plug that looks like the one in the accompanying illustration. Make
sure that the product is connected to an outlet having the same configuration as the plug.

Item

Description

1

Grounded Outlet Box

2

Grounded Outlet

3

Grounding Pin

DANGER: A risk of electrical shock may result from improper connection of the equipment grounding
conductor. Check with a qualified electrician if in doubt as to proper grounding technique. DO NOT modify the
plug provided with the product. If it will not fit an electrical outlet, have a proper outlet installed by a qualified
electrician. Any modification to the electrical plug will result in a voided warranty.

Immobilization Method

The purpose of immobilizing the PowerMill is to prevent unauthorized use. The system causes immobilization of the
PowerMill when a pre-defined hard key sequence has been activated.

To prevent false toggling of the Immobilized feature, this sequence must be done in a 5-10 second period.

1.

Press the 

STOP

 key 3 times.

2.

Press the 

SPEED DOWN

 arrow key 3 times.

Page 6 of 23

Summary of Contents for PowerMill 95PS-XX03

Page 1: ...Life Fitness PowerMill Climber Assembly Instructions 95PS XX03 95PS XX04 Assembly Instructions 1015938 0001 REV AA...

Page 2: ......

Page 3: ...r Position 16 Remove Line Cord Bracket and Secure Power Cord 17 Service and Technical Data Preventive Maintenance Tips 18 Approved and Compatible Cleaners 18 Preventive Maintenance Schedule 19 How To...

Page 4: ...de turn off the power unplug the power cord from the outlet and carefully retrieve it If the item cannot be reached contact Customer Support Services Never place liquids of any type directly on the un...

Page 5: ...this unit is designed for use only in a controlled setting The PowerMill Climber is not designed for use in the home and should not be used in an environment where children or animals might have acces...

Page 6: ...uit l ext rieur pr s d une piscine ou dans des endroits tr s humides N utilisez jamais le produit avec les ouvertures d air bloqu es Maintenez les bouches d a ration exemptes de peluches de cheveux ou...

Page 7: ...d un appareil motoris Cet appareil motoris permet de faire descendre les marches d escalier des vitesses variables et op re donc diff rents niveaux simultan ment Au cours d un entra nement classique...

Page 8: ...with all local codes and ordinances NOTE A temporary adapter MUST NOT BE USED to connect this plug to a two pole receptacle in North America If a properly grounded 15 amp outlet is not available one...

Page 9: ...y Instructions move the unit to the location in which it will be used See Specifications for the dimensions of the footprint The location must have a minimum ceiling height of 9 ft 2 7 m Allow at leas...

Page 10: ...izing feet on the unit Check the front and back stabilizing feet to determine which foot does not rest fully on the floor Rotate the foot counterclockwise to lower it Recheck the stability and adjust...

Page 11: ...8 mm Hex washer head screw 4 6 M4 X 16 mm Phillips pan head screw 7 7 M4 X 12 mm Phillips pan head screw 25 8 M5 X 14mm Phillips pan head screw Discover Console 4 M5 X 14mm Phillips pan head screw Int...

Page 12: ...Item Description Qty 1 Step Assist Left 1 2 Step Assist Right 1 3 M8 X 35mm Socket Head Cap Screw 6 18 20 ft lbs 24 4 27 1 Nm Install Left and Right Rear Uprights Item Description Qty 1 Rear Upright L...

Page 13: ...3 M8 X 18mm Hex Washer Head Screw 4 4 Cables 18 20 ft lbs 24 4 27 1 Nm Secure Top Cover to Base 1 Install plastic grommets into the front panel shroud Item Description Qty 1 Plastic Grommet 3 2 Use s...

Page 14: ...Rear Left 1 3 L Tube Front Handlebar Right 1 4 Handlebar Rear Right 1 5 M8 X 16mm Button Head Cap Screw 4 16 18 ft lbs 21 7 24 4 Nm 2 Secure the left and right handlebar assemblies to the console supp...

Page 15: ...ssory Tray Bottom Left 1 10 12 in lbs 1 1 1 3 Nm Attach Handlebar Covers Item Description Qty 1 Rear Handlebar Cover Outer Left 1 2 Rear Handlebar Cover Inner Left 1 3 Rear Handlebar Cover Outer Right...

Page 16: ...e to Console Cable Connections Integrity X C Item Description Qty 1 Console to Base Power 1 2 Base Signal 1 3 Left Handlebar Keypad Switch 1 4 Lifepulse 1 5 Right Handlebar Keypad Switch 1 Base to Con...

Page 17: ...r Console Shroud Assembly 1 Secure ground screw to console 2 Use the remaining four M5 X 14 Phillips Pan Head Screws to secure both the console and rear console shroud assembly to the console support...

Page 18: ...Tighten Hardware and Verify Leg Leveler Position Tighten all hardware and make sure all leg levelers are down Item Description Qty 1 Leg Leveler 4 Page 16 of 23...

Page 19: ...rew Item Description Qty 1 Bracket Line Cord 1 2 M4 X 12mm Phillips Pan Head Screw 1 2 Plug in power cord and reattach line cord bracket and screw Item Description Qty 1 Bracket Line Cord 1 2 M4 X 12m...

Page 20: ...pment PureGreen 24 and the Antibacterial Force formula of Gym Wipes are both disinfectants that are effective against MRSA and H1N1 PureGreen 24 is available in a spray which is convenient for gym sta...

Page 21: ...on a cloth Drive Chain Inspect Clean Lubricate Clean and lightly lubricate with 30w oil on a cloth Chain Sprockets Inspect Clean Lubricate Wipe off excess old grease and lightly apply lithium based g...

Page 22: ...If cracks appear 2 cm or less apart then 80 of the belt life is gone and the belt should be replaced Belt Wear Material Loss If material loss is occurring as shown above the belt should be replaced N...

Page 23: ...vable cup holders four wheels for easy mobility thumb resistance controls Console Options Discover SE3 Discover SE3 HD ST Integrity X Integrity C Integrity SL Display Type 16 LCD Surface Capacitive To...

Page 24: ...on is not covered by warranty All terms of this warranty are void if this product is moved beyond the continental borders of the United States of America excluding Alaska Hawaii and Canada and are the...

Page 25: ...warranty Effects of State Laws This warranty gives you specific legal rights and you may have other rights which vary from state to state and country by country Warranty Information Base 2 years 1 Ye...

Page 26: ......

Reviews: