background image

 

PREFACE 

 

Thank you for choosing a gasoline generator set by our Co. 

Based on the latest technology at home and abroad, our Co. has successfully developed the gasoline 

generator set. The unit is characterized by advanced design, compact structure, reliable performance, 

convenient service, low fuel consumption and noise as well as fashion shape. With general gasoline engine as 

power, it is widely used in many fields such as living, open working, shop, bank, fishing, etc. 

The manual gives information with respect to operation and maintenance of the gasoline generator, and be 

sure to read it carefully first before operating. If any trouble occurs, call your dealer who will provide you with 

the best after service. 

All the materials and diagrams of this manual are in accordance in this manual may be a little different 

from the actual stares. The copyright of this manual belongs to our Co., any group or individual is forbidden to 

reprint or copy any it. The manual is subject to change without notice. 

 

Summary of Contents for 1.3GF

Page 1: ...in many fields such as living open working shop bank fishing etc The manual gives information with respect to operation and maintenance of the gasoline generator and be sure to read it carefully first...

Page 2: ...ures may result in injury to or death of personnel if not strictly observed CAUTION A caution is used to alert the user to fact that hazardous operation and maintenance procedures may result in injury...

Page 3: ...r Safety 4 Introduction to Parts and Components 6 Pre Operating Inspection 9 Starting the Engine 13 Service 14 Stopping the Engine 19 Maintenance 20 Storage 24 Troubleshooting 26 Wiring Diagram 28 Spe...

Page 4: ...FETY 1 Never operate it in an enclosed room Fig 1 2 Fig 1 1 2 Never connect to home circuit Fig 1 3 Fig 1 4 3 Do not operate it under wet circumstances 4 Place inflammables away from the unit at least...

Page 5: ...5 No smoking when filling fuel Fig 1 5 Fig 1 6 6 Always fill fuel after stopping it Fig 1 7 7 Do not spill out when filling fuel 5...

Page 6: ...TS 1 Fuel tank 2 Muffler 3 Earth terminal 4 AC plug socket 5 Carburetor choke lever 6 Starter handle 7 Fuel cock 8 Air cleaner 9 Pipe frame 10 Spark plug Fig 2 1 11 Fuel filler cap 12 AC breaker 13 Di...

Page 7: ...tank 2 Muffler 3 Earth terminal 4 AC plug socket 5 Carburetor choke lever 6 Starter handle 7 Fuel cock 8 Air cleaner 9 Pipe frame 10 Spark plug 11 Fuel filler cap 12 Ignition switch 13 AC circuit pro...

Page 8: ...1 Fuel tank 7 Air cleaner 2 Muffler 8 Pipe frame 3 AC plug socket 9 Spark plug 4 Carburetor choke lever 10 Fuel filler cap 5 Starter handle 11 Ignition switch 6 Fuel cock 12 AC breaker 8...

Page 9: ...el ground 1 Turn out the oil filler cap and clean the dipstick with a clear clothe 3 In the case that the oil lever is below the lower level mark of the dipstick fill oil to the upper level mark of th...

Page 10: ...2 FUEL LEVER 5 Open the fuel filler cap 7 Fill fuel to the shoulder of the filter 6 Check the fuel level and fill fuel if necessary 8 Reinstall the fuel filler cap well 10...

Page 11: ...3 BATTERY only for 2GF 4 Check and make sure that the electrolyte level of each battery cell is between is upper and lower level marks Fig 20 1 upper level mark 2 lower lever mark 11...

Page 12: ...using 3 for 1 3GF 3 2GF 3 or turn off the wing nuts and air cleaner cover for 1 3GF 1 3GF 2 2GF 2GF 2 Fig 3 12 4 Put the filter element into original position install the cover and secure it well Fig...

Page 13: ...AC breaker Remove all loads from AC socket Fig 4 1 2 Set the fuel cock to ON Fig 4 2 3 Push the choke lever to OFF Fig 4 3 4 Turn the generator ignition switch to ON Fig 4 4 5 Pull the start handle g...

Page 14: ...4 6 NOTE Don t close the choke when starting the engine in hot condition SERVICE Always do as the following so as to keep the generator in a sound condition WARNING 1 Always connect the generator to...

Page 15: ...cription Start Rating Typified Electric device Start Rating Incandescent lamp Heating device 1 Incandescent lamp TV Incandescent lamp 100W 100VA W 100VA W Fluorescent lamp 2 1 5 Fluorescent lamp Fluor...

Page 16: ...3 If the generator is to supply two or above loads with power supply be sure to connect them one by one with higher start current first Fig 5 3 16...

Page 17: ...NING When connect the generator to home power supply be sure that a skilled electrician does this job Improper connecting between the generator and loads may cause damage to the generator even a fire...

Page 18: ...4 USE INSTRUCTION WHEN PROVIDING ALTERATIVE CURRENT SUPPLY 1 Start the generator 3 Switch on the AC breaker 2 Connect devices 18...

Page 19: ...STOPPING THE ENGINE 1 Switch off the AC breaker 3 Set the fuel cock to OFF 2 Turn the ignition switch to OFF NOTE To stop the generator in an emergency turn the ignition switch to OFF 19...

Page 20: ...very 6 months Or every one Year Ref page Engine oil check Check P 9 Replace engine oil Replace Replace P 20 Air cleaner check Check P 11 Air cleaner wash Clean P 11 Oil filter cup Clean P 22 Oil filte...

Page 21: ...ine oil from the crankcase mark of the dipstick Engine oil 4 stoke gasoline engine oil engine oil Class SE SE from API Service Classification or SAE10W 30 engine oil equivalent to Class SG Low air tem...

Page 22: ...spark plug cap front the spark plug Fig 7 6 2 Dismantle the spark plug by means of a special tool Fig 7 7 3 Clear away carbon fouling around the spark plug Fig 7 8 4 Check the spark plug gap and adju...

Page 23: ...1 Set the fuel cock to OFF and dismantle the fuel filter cup 2 Clean the fuel filter cup thoroughly by blowing off in the reverse direction of the arrowhead 3 Fit a new rubber ring to position and mou...

Page 24: ...he fuel inside Fig 8 1 2 Set the fuel cock to ON and empty the fuel from the fuel tank Fig 8 2 3 Replace the rubber ring with a new one and than turn right the filter cup Fig 8 3 4 Screw off the fuel...

Page 25: ...tall the oil drain plug and then fill engine oil to the upper level mark of the dipstick Fig 8 6 7 Pull up the handle gently until feeling an anti action Fig 8 7 8 Place the unit in the clean area Fig...

Page 26: ...ails to start 1 Check to see of the generator switch is at ON 2 Check engine oil 3 Check the fuel inside level tank 4 Remove the spark plug and check it for proper sparks 5 If the generator set if sti...

Page 27: ...2 TROUBLE The unit fails to generator electricity 1 Check the light bulb 2 Check to see if the AC breaker is at ON 3 If such check is still unsatisfactory see your dealer for help 27...

Page 28: ...WIRING DIAGRAM 28...

Page 29: ...29...

Page 30: ...30...

Page 31: ...nition system Non contact transistor Start system Hand operated Fuel tank capacity L 3 7 9 2 15 15 Fuel consumption L hr 0 92 0 92 0 92 0 98 Duration of runs h 3 8 9 8 16 14 Engine oil capacity L 0 6...

Page 32: ...e 4 stroke OHV single cylinder gasoline engine with forced air cooled Displacement cm3 196 196 196 196 Maximum power output kW rpm 4 8 3600 4 8 3600 4 8 3600 4 8 3600 Ignition system Non contact trans...

Page 33: ...length mm 435 435 435 435 Generating set Dry mass kg 36 40 45 47 51 BATTERY To install the battery proceed as follows 1 Assemble the battery with nuts bolts and washers 2 Connect the starting cable t...

Page 34: ...1 Starting motor 2 Starting cable 3 Protective frame 4 Battery bracket 5 Battery guard 6 Retaining frame 7 Battery with a rating of 12V 35Ah 8 Negative wire 34...